My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1020 N BROADWAY 2019 Plans 2022-12-06
>
Address Records
>
N BROADWAY
>
1020
>
Plans
>
1020 N BROADWAY 2019 Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 1:22:35 PM
Creation date
8/4/2021 8:58:45 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1020
Permit
B1804-011
Year
2019
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HARDWARE TYPES <br /> HS-1 <br /> (1) 3710 ENTRY/SINGLE LOCKING INTERCONNECTED <br /> (3) HINGES HAGER BB1279 4.5"X4.5" US26D <br /> (1) CLOSER 5200-MTL-14-US26D-NHOTA-SLC US26D HAGER <br /> (1) 1/4" RISE THRESHOLD 417SX36" MIL FINISH HAGER <br /> (1)AUTO DOOR BOTTOM 730SNX36" MIL FINISH HAGER <br /> (1) GASKET 721 CHA HAGER <br /> (1)VIEWER W/PRIVACY FLAP 1759 US26D HAGER <br /> (NOTE: AT TYPE"A" UNITS PROVIDE AN ADDITIONAL PRIVACY VIEWER WITH FLAP- <br /> MOUNT AT 42"AFF TO CENTERLINE OF PEEP HOLE.) <br /> HS-2 <br /> (1) PRIVACY LEVER 3540-2 3/4"- US26D-ARC -TEE US26D HAGER <br /> (3) HINGES HAGER BB1279 4.5"X4.5" US26D HAGER <br /> (1) HAGER 6000 SERIES MEDUIUM DUTY SURFACE MOUNT OVERHEAD STOP <br /> (3) SILENCERS 307D GRA HAGER <br /> HS-3 <br /> (1) PASSAGE LEVER 3510-2 3/4"- US26D-ARC-TEE US26D HAGER <br /> (3) HINGES HAGER BB1279 4.5"X4.5" US26D HAGER <br /> 6" <br /> �i <br /> Ili I HS-4 <br /> (1) (EXTERIOR SIDE) EXIT DEVICE TRIM 45CE <br /> / nimi - lin - (1) (INTERIOR SIDE) KAWNEER 1790 CONCEALED ROD EXIT DEVICE <br /> / a / \ / A <br /> (1) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER <br /> / (1) TOP/BOTTOM/INTERMEDIATE PIVOT HINGES <br /> / / <br /> / / \ / (1) ULTRALINE ELECTRIC STRIKE 74R1 - 130 <br /> / . (1) PROXIMITY CARD READER <br /> / <br /> ` . ADA THRESHOLD STANDARD 1/2" <br /> WEATHER-STRIPPING AND BOTTOM SWEEPS <br /> `r' "' - PROVIDE KEYED LOCKING CORE FOR FD/MASTER KEY ACCESS <br /> / <br /> o / DOOR SHALL BE WIRED TO "DOOR KING 1835-080" PROGRAMMABLE CONTROL SYSTEM <br /> / / <br /> , <br /> 'in / / HS-5 <br /> I �' ` ' (1) KEY PAD OR CARD STANDARD ENTRY HARDWARE (TBD) <br /> -BATTERY POWERED ACCESS CONTROL <br /> TYPE A TYPE B TYPE C TYPE D TYPE E TYPE E (3) HINGES HAGER BB1279 4.5"X4.5" US26D HAGER <br /> (1) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER <br /> Note: Glazing in 90min (1) KICKPLATE 194S- 34"X10" US32D HAGER <br /> doors shall have a max. <br /> (1)ADA THRESHOLD STANDARD 1/2" <br /> glazing area of n. (1) SWEEP 750SNX36" MIL HAGER <br /> Dimension of Gazing to be 3"x 33" (1) GASKET 721S CHA HAGER <br /> HS-6 <br /> (1) STOREROOM LEVER 3580-2 3/4"- US26D-ARC - SCC - KD-TEE US26D HAGER <br /> • DOOR SCHEDULE (3) HINGES HAGER BB1279 4.5"X4.5" US26D HAGER <br /> (1) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER <br /> DOOR DOOR FRAME (1) KICKPLATE 194S- 34"X10" US32D HAGER <br /> (1)THRESHOLD 417SX36" MIL HAGER <br /> FRAME (1) SWEEP 750SNX36" MIL HAGER <br /> MARK LOCATION COUNT DOOR TYPE HEIGHT WIDTH DOOR MATERIAL DOOR FINISH MATERIAL FRAME FINISH FIRE RATING HARDWARE TYPE NOTES (1) GASKET 721S CHA HAGER Permit Set <br /> 001 Unit Entry 124 A 6'-8" 3'-0" WD Solid Paint Steel Timely TA-8 20MIN HS-1 HS-7 B 1 804-01 1 <br /> 002 Unit Bathroom 116 A 6'-8" 2'- 10" WD Solid Paint Steel Timely TA-8 HS-2 (1) PASSAGE LEVER 3510-2 3/4"- US26D-ARC-TEE US26D HAGER <br /> 003 Unit Bathroom 8 A 6'-8" 3' (1) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER 0" WD Solid Paint Steel Timely TA-8 HS-2 (3) HINGES HAGER BB1279 4.5"X4.5" US26D HAGER <br /> 004 Exit Stair 10 B 6'-8" 3'-0" WD Solid Paint Steel Timely TA-8 90MIN HS-7 (1) <br /> THRESHOLD <br /> 417SX36" MIL HAGER <br /> 005 Lobby Entry From Parking Garage 1 C 6'-8" 3'-0" Steel Paint Steel HS-7 (1) SWEEP 750SNX36" MIL HAGER <br /> 006 Laundry Room 4 C 6'-8" 3'-0" WD Solid Paint Steel Timely TA-8 20MIN HS-7 (1) GASKET 721S CHA HAGER <br /> 007 Entry Storefront 1 D 7'- 10 3/4" 3'- 1" Alum. Storefront Anodized Alum. Storefront HS-4 REGISTERED <br /> 008 Common Area Bathroom 1 A 6'-8" 2'- 10" WD Solid Paint Steel Timely TA-8 HS-9 HS-8 ARCH <br /> ITECT <br /> (1) EXIT DEVICE 4501 RIM - FR-36-US26D- 1 3/4" US26D HAGER RC TE <br /> 009 Mechanical Room 1 A 6'-8" 3'-0" Steel Paint Steel Timely TA-8 HS-6 (1) EXIT DEVICE TRIM 45BE-ARC - US26D - 1 3/4" US26D HAGER <br /> 013 <br /> 10 Electrical Room 1 A 6'-8" 3'-0" Steel Paint Steel HS-8 Door Shall have Panic Hardware (3) HINGES HAGER BB1279 4.5"X4.5" US26D HAGER <br /> 010b Electrical Room Exterior 1 A 6'-8" 3'-0" Steel Paint Steel HS-8 Door Shall have Panic Hardware (1) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER Joshua S.Scott <br /> A 1 <br /> 01 Exit Stair 1 D 6' 8" 3'-0" Steel Paint Steel HS-5 Locking with free direction in the direction of egress travel (1) KICKPLATE 194S- 34"X10" US32D HAGER STATE OF WASHINGTON <br /> 012 Parking Garage Entry 1 C 6'-8" 3'-0" Steel Paint Steel HS-5 Locking with free direction in the direction of egress travel (1) THRESHOLD 417SX36" MIL HAGER <br /> 013 Riser Room 1 A 6'-8" 3'-0" Steel Paint Steel 20MIN HS-6 (1) SWEEP 721S C36" MIL HAGER <br /> (1) GASKET 721S CHA HAGER <br /> 014 Leasing Office 1 D 6'-8" 3'-0" Steel Paint Steel HS-13 <br /> 015 Garbage Room Levels 2-5 4 C 6'-8" 3'-0" WD Solid Paint Steel Timely TA-8 45MIN HS-7 Doors Shall be Self-Closing / HS-9 <br /> 017 Main Garbage Room 1 E 6'-8" 6'-0" Steel Paint Steel HS-16 (1) 3540 I Y <br /> SET <br /> 018 Elevator Control Room 1 A 6'-8" 3'-0" Steel Paint Full 4-Side Weld 90MIN HS-10 Control Room Shall be Key Lockable, Reserved Exclusively for the Elevator Control Equipment. (3) HINGES HAGER BB1279 4.5"X4.5" US26D <br /> (1) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER <br /> 019 Roof Access 2 A 6'-8" 3'-0" Steel Paint Full 4-Side Weld 90MIN HS-11 Locked from interior (1) 1/4" RISE THRESHOLD 417SX36" MIL FINISH HAGER <br /> 021 Electrical Closet 4 A 6'-8" 2'-6" WD Solid Paint Steel Timely TA-8 HS-6 (1)AUTO DOOR BOTTOM 730SNX36" MIL FINISH HAGER <br /> (1) GASKET 721 CHA HAGER <br /> HS-10 <br /> Access Controls with card key access shall be installed on the following doors: (1) STOREROOM LEVER 3580-2 3/4"- US26D-ARC -SCC - KD-TEE US26D HAGER <br /> Overhead Garage Door (1) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER <br /> Main Building Entry#007 (3) HINGES HAGER BB1279 4.5"X4.5" US26D HAGER <br /> Parking Garage Access#012 (1) GASKET 721S CHA HAGER <br /> Stair Access/Entry#011 <br /> Garbage Room #017 HS-11 <br /> (1) DEABOLT 3214-2 3/4"- US26D- SC - KD - NO - LIP US26D HAGER (DOUBLE SIDED LOCK) <br /> (2) HAGER 33G PULL PLATE HANDLES <br /> (1) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER <br /> (3) HINGES HAGER BB1279 4.5"X4.5" US26D HAGER <br /> (1) GASKET 721S CHA HAGER <br /> HS-12 <br /> (1) PULL TRIM M33/628 (MOUNT 39 1/2" FROM BOTTOM OF DOOR) <br /> (1) PUSH TRIM M52/628 (MOUNT 39 1/2" FROM BOTTOM OF DOOR) <br /> (1) CLOSER 8956 PKT <br /> (1) MAGNETIC HOLDER TDH200 WALL MOUNT <br /> (1) MORTIISE SWEEPS <br /> (1) SMOKE SEAL ALL EDGES <br /> HS-12 <br /> HS-13 <br /> (1) 3550 ENTRY/OFFICE LOCKSET <br /> (3) HINGES HAGER BB1279 4.5"X4.5" US26D 2 09/01/19 Set II Rev 1 <br /> (1) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER # DATE DESCRIPTION <br /> (1) 1/4" RISE THRESHOLD 417SX36" MIL FINISH HAGER <br /> DOOR SCHEDULE -GENERAL NOTES (1)AUTO DOOR BOTTOM 730SNX36" MIL FINISH HAGER <br /> (1) GASKET 721 CHA HAGER <br /> KEY SCHEDULE 1. ACCESS CONTOLS FOR EXTERIOR ENTRIES SHALL HAVE BATTERY BACKUP OR <br /> SHALL BE CONNECTED TO EMERGENCY POWER FOR ACCESS IN THE EVENT OF HS-14 <br /> RES. UNITS: INDIVIDUAL UNIT KEY WITH CARD KEY ACCESS. POWER FAILURE. (1) SUGATSUNE HC-3051 SERIES SLIDING DOOR LATCH (NON-LOCKING) <br /> RES. ENTRY LOBBY: BUILDING MASTER AND SERVICE ACCESS KEY WITH CARD KEY ACCESS. 2. ALL COMMON AREA DOORS AND UNIT ENTRY DOORS SHALL COMPLY WITH (1) HAGER 9631 HEAVY DUTY POCKET DOOR KIT(125LB DOOR WEIGHT) DEVELOPMENT <br /> BASEMENT PARKING: BUILDING MASTER AND SERVICE ACCESS KEY WITH CARD KEY ACCESS. ACCESSIBILITY REQUIREMENTS FOR OPENING FORCE AND CLOSING SPEED <br /> BASEMENT STAIR: BUILDING MASTER AND SERVICE ACCESS KEY WITH CARD KEY ACCESS. (EXCEPTION: FIRE DOORS). HS 15 <br /> 3. ALL DOORS WITH VISION PANELS MUST HAVE BOTTOM OF GLAZING MAX. 43"AFF 1830 BICKFORD AVE, <br /> LEVEL 1 STAIR(S): BUILDING MASTER AND SERVICE ACCESS KEY WITH CARD KEY ACCESS. [PER ICC/A117.1-2009 SECTION 404.2.10] HS 16 SUITE 201 <br /> BIKE STORAGE: BUILDING MASTER AND SERVICE ACCESS KEY WITH CARD KEY ACCESS. 4. ALL GLAZED AND OPAQUE EXTERIOR DOORS SHALL HAVE A MINIMUM U-FACTOR (1) 3550 ENTRY/OFFICE LOCKSET SNOHOMISH, WA 98290 <br /> GARBAGE ROOM: TBD 2 281 D SLIDE FLUSH BOLT(BOTTOM/TOP INSTALLED ON INACTIVE LEAF) 206.755.1290 <br /> OF 0.370 AS REQUIRED. ( ) <br /> MECH. RM.: BUILDING MASTER AND SERVICE ACCESS KEY. 5. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON (1) 280X DUST PROOF STRIKE (BOTTOM ONLY) <br /> ROOF ACCESS: BUILDING MASTER AND SERVICE ACCESS KEY. DOORS REQUIRED TO BE ACCESSIBLE BY CHAPTER 11 SHALL NOT REQUIRE (6) HINGES HAGER BB1279 4.5"X4.5" US26D <br /> FIRE RISER RM.: BUILDING MASTER AND SERVICE ACCESS KEY. TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. (2) CLOSER 5100-MLT-14-US26D-HDSC-FC HAGER <br /> ELECTRICAL RM.: BUILDING MASTER AND SERVICE ACCESS KEY. 6. DOORS WITH LESS THAN 9SF OF GLAZING SHALL BE TYPE I CLASSIFICATION, (2)AUTO DOOR BOTTOM 730SNX36" MIL FINISH HAGER <br /> DOORS WITH GREATER THAN 9SF TO BE TYPE II.AS GOVERNED BY IBC TABLE (1) GASKET 721 CHA HAGER <br /> GEN. ACCESS: BUILDING MASTER AND SERVICE ACCESS KEY. 2406.2(1). 1020 North Broadway <br /> LEVEL 1 JANITOR CLO: BUILDING MASTER AND SERVICE ACCESS KEY. 7. STEEL DOORS IN CONCRETE STEEL DOORS IN CONCRETE WALLS TO BE"KNOCK Everett,WA 98403 <br /> ELEVATOR CONTROL RM.: BUILDING MASTER AND ELEVATOR ACCESS KEY. DOWN" PUNCH AND DIMPLE ANCHOR INSTALLATION. <br /> RETAIL 8. TYPE A UNITS REQUIRE A SECOND PEEPHOLE MOUNTED AT 43"AFF <br /> BASEMENT AND LEVEL 1 RETAIL TO BE KEYED SEPERATELY(PROVIDE DUPLICATES). 9. VISION PANELS SHALL NOT BE LIMITED IN 2HR AND 1 HR FIRE RATED DOORS IF <br /> BUILDING IS SPRINKLERED PER EXCEPTION "D" IBC TABLE 716.5. <br /> DOOR SCHEDULE & DETAILS <br /> PROVIDE MASTER KEY IN KNOX BOX-OR AS DIRECTED BY AHJ <br /> DATE: Issue Date <br /> • <br /> SHEET: <br /> A7 . 01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.