Laserfiche WebLink
(4) #5 ® 6"oc <br /> CENTERED IN SLAB <br /> CL SUPPORT CL SUPPORT CL SUPPORT -=._�;-- FOSSATTI PAWLAK <br /> sm <br /> STRUCTURAL <br /> /4" / L1 / L2 / 35Westlake ENGINEERS <br /> Ave <br /> eN,Ste05 <br /> MII\( Seattle,WA 98109 <br /> NO STL PIPE INSERT IS Phone:206.456.3071 <br /> 4 6" MIN z REQ"D FOR SLAB FOR TENDON CENTER OF Li/2 / L1/2 / L2/2 y L2/2 / Fax:206.456.3076 <br /> PENETRATIONS OUTSIDE THE GRAVITY ABOVE BOT OF INFLECTION www.fossatti.com <br /> OPENING7 (1) 4 T&B EACH SIDE SLAB 111 `�' 45' ZONE OF ANCHOR ITI SLAB, OR BOT OF DROP POINTS <br /> EDGE OF PT SLAB # BAND REF PLAN <br /> 1�1 4. ! 1 <br /> — SLEEVE THRU SLAB ° a y P. P ��, <br /> ��6., ��� 45 STD STL PIPE INSERTS REQ"D \ 1 i \ 4;: \--- WASH /,� "�, <br /> `�� 2Y"" MIN WHEN SLAB PENETRATIONS ARE = 0.1L 0.1L2 = , � ' <br /> �� WITHIN THE 45' ZONE OF ANCHOR ":air.-.`-)P F� %,,,,:,, 4...... <br /> I TENDON PROFILE <br /> 't <br /> (REVERSE PARABOLA) N�I ■� <br /> TENDON LOCATION / 1 `� 0�f' 23024 \�� <v�� <br /> CANTILEVER INT SPAN END SPAN <br /> STL PIPE INSERTS ARE SPAN / <v\d' Twat- EA �4 <br /> NOT REQ'D FOR SLAB ,rr`SIDNAL 40�' <br /> PENTRATIONS LOCATED r�2��`�� <br /> FURTHER THAN TWICE THE <br /> \cs' / 1 MIN'/ / OPNGS GREATER DIMENSION PROJECT <br /> (361" MIN) FROM ANCHORS <br /> NOTE: <br /> 1. GROUPS OF PENETRATIONS W/ AREA>,144 IN' <br /> TO BE REINFORCED PER 5/S3.2. <br /> CO <br /> Q <br /> Ca <br /> . TYP RE-ENTRANT CORNER REINF IN SLAB 10 SLAB OPENINGS 7 SLAB PENETRATIONS AT POST TENSIONED ANCHORS 4 TYP POST-TENSIONED SLAB PROFILE 1 0 ♦; <br /> ao }' <br /> a) <br /> z a, <br /> o <br /> N W <br /> TENDONS SHALL BE/ O <br /> NOTES: '.TRAIGHT IN THIS AREA <br /> 1. SEE PLAN FOR ADDITIONAL SLAB INFORMATION. <br /> 2. REINFORCING TO BE CENTERED IN SLAB. , 1Y" CLR ' <br /> y/ 1 -0" MIN <br /> TYP TYP <br /> CD <br /> O' C' L)))) 1--- - <br /> (1) #5 T&B DIAL 18," X SUPPORT BARS A, <br /> o d- 6 MIN (2) #5 T' TYP ® EA CORNER #3 x ) (H-2") HAIRPINS EA <br /> (1) #5 x 4'-0"" (1) <br /> 1 I __— i.` SIDE OF ANCHOR AS INDICATED / 1 -6 / 1"-6" <br /> / <br /> #5 x 6-0 (1) #5 STAGGER #3 HAIRPINS V (H = SLAB THICKNESS) AT TOOLED JOINT W/ CAULK <br /> x 8"-0" (1) #5 x / OPENING I iH 4 1 AT EXPOSED SLABS PREVISIONS <br /> 10-0 CO 12"oc �� ` ' )( <br /> OF (4) OR MORE SDS T TENDONS // / -#4 x 48" LONG <br /> _ ,,71,, (� 16"oc MID-DEPTH <br /> // PT TENDONS -T-SLAB_ ° NO. DATE <br /> SFC PROVIDE REINF T&B EQ TO ONE-HALF `� PER PLAN a kI' I °° <br /> (4) #4 x 6'-0" �0N �, THE AREA OF SLAB REINF CUT BY T <br /> � ° 7/01/19 PERMIT REVISIONS <br /> ® 12"oc gyp,. OPNG ((2) #5 T&B ALL SIDES MIN) <br /> 1�1 �i /,p c <br /> �� 1 -0 TO 2-0 = �,, Q „ <br /> 4'-0" / MIN, TYP n n 1 x2Y x12 KEY ® 48 oc /� <br /> Yi <br /> PLAN NOTES: <br /> 18" MAX BETWEEN TENDONS <br /> Y" CHAMFER / 9/17/19 PERMIT REVISIONS <br /> ADDED #3 x D HAIRPINS <br /> SLAB EDGE1. <br /> 1'-6" ALL OPENINGS WITH A DIMENSION OF 12" OR GREATER SHALL BE TRIMMED WITH REINFORCING. <br /> (2) #4, TYP 1" CLR BTWN @ 12"oc FOR EVERY (4) TENDONS. NOTES: <br /> TENDONS MIN TYP// STAGGER #3 HAIRPINS 2. THIS REINFORCING IS IN ADDITION TO ANY REINFORCING INDICATED ON PLANS. THE ENGINEER SHALL APPROVE THE USE AND LOCATION (2) #4 BACKUP BARS CONT <br /> (2) #4 CONT, TYP 3. WHERE AN ADJACENT OPENING IS CLOSER THAN THE SMALLER OPENING DIMENSION, EXTEND TRIM OF ALL POST-TENSIONED SLAB CONSTRUCTION JOINTS. <br /> T SLAB_ REINFORCING TO 24" MINIMUM PAST ADJACENT OPENINGS. <br /> PER PLAN ° e ° 4. HOOK REINFORCING AT SLAB EDGE WHERE THE OPENING EDGE TO SLAB EDGE IS CLOSER THAN 24". <br /> SECTION <br /> CORNER REINF @ POST-TENSIONED SLAB EDGE 11 POST-TENSIONED TENDONS W/ SWEEP GREATER THAN 1 :6 8 TYP POST-TENSIONED LAYOUT AT SLAB OPENING 5 TYP POST-TENSIONED SLAB CONSTRUCTION JOINT 2 <br /> 5/28/19 19-042 <br /> DATE JOB# <br /> ri■■■■ ---- ■■■■ DROP CAP / / 1"-6"' H/4 FPP <br /> 1■■■■■�■■■■■1 /� CHORD (2) #4 CONT DESIGN CHECKED <br /> I■■■■■!GNIMEM ■ \ 1 -6 a H/4 -(2) #4 STEEL / / / TCB <br /> 1■■■■■�■■■■■1 ° ° -(2) #4 BACKUP °°d <br /> I■■■■■�___-IIIII <br /> 11111 <br /> DROP COLUMN ANCHORAGES 12"' WHEN l ° 18"" ° ° ° ° DRAWN SCALE <br /> ES OF COL 1 - I MORE THAN (2) ARE SECTION #3 x (H-2") HAIRPINS EA SIDE \ SECTION (2) #4 BACKUP BARS CONT <br /> CONT TENDONS PLACED IN ONE LOCATION 1'-0" MIN OF ANCHOR AS INDICATED (H=SLAB <br /> I■■■■■11=111111111111■■■■■I (1) ADD"L HAIRPIN <br /> I■I■■■ ■■■■■I DIST TENDONS THICKNESS) AT GROUPS OF (4) OR <br /> EA SIDE OF BANDED 18" <br /> I■■■■■�■■■■■■I PER PLAN TENDON GROUP MORE DIST TENDONS (2) #4 CONT #3 x (H-2") HAIRPINS EA SIDE <br /> I■■■■■�■■■■■■1 <br /> 6 6 (2) #4 BACKUP CHORD STEEL <br /> ■■■■■�■■■■ ` IIIII� / / _/ OF ANCHOR AS INDICATED <br /> ---- BARS CONT <br /> (H=SLAB THICKNESS) @ GROUPS OF <br /> NOTE: I <br /> (4) OR MORE DIST TENDONS <br /> PASS TOP BARS NEAR CENTER OF COLUMN PLAN DET ADDED TENDONS 11 ��— \ —�- • I .- =-1 '.F BANDED TENDONS PER PLAN <br /> UNDER DISTRIBUTED TENDONS AND TOP BARS 6 (MIN) - <br /> NEAR EDGES OF DROP CAPS OVER DISTRIBUTED -^ , C- • --. <br /> (2) TENDONS MIN �� C A <br /> TENDONS AS REQUIRED FOR 1Y" COVER TO TO PASS OVER COL I — "' <br /> POST-TENSIONING AND 1" TO REBAR IN EACH DIRECTION SUPPORT BARS _mil I.� = SECTION <br /> 6 x SLAB T �-^ — --i .I = (2) #4 BACKUP BARS CONT <br /> / OR 48" MAX, TYP / BY OTHERS AS REQ D / 1"-6" 1 Q ^ -. SLAB EDGE SHEET TITLE <br /> (6) #4 L ES OF COL L SUPPORT BAR 6 (MIN) • z SECTION <br /> DISTRIBUTED --I Z CL SUPPORT CL SUPPORT ,� m I ( x <br /> TENDONS I m BANDED TENDONS L/4 OR 4-0 MIN FROM FACE OF SUPPORT / BAR BAR , � o "' <br /> ^ ° I ° I I , 1- I {i TYPICAL <br /> • • `• •1 • co • • • • — ° d < .d - ° E -. .1 III <br /> • <br /> �, • off, ° a a ° _ PT DETAILS <br /> ° c da -. <br /> = z DET ° � ° ° - <br /> �, Q °-- \ I I \''''.---.'",-,,,,,. <br /> SLAB EDGE <br /> 8" "" .•••A/ V•• • (2) #7 SUPPORT BARS 1 CHAIR BY I <br /> • o <br /> �` TYP (� DROP CAPS OTHERS, TYP = I PLAN / 6" DIST TENDONS PER PLAN <br /> lik, \ <br /> (12) #4 EW BANDED TENDONS 1 <br /> MIN (2) #4 BACKUP PER PLAN PLAN (2) #4 CONT NOTES: <br /> Y" MAX PENETRATION ), (2) #4 x 6'-0" EW BARS CONT, TYP (2) #5 BOT 6" CHORD STEEL SHEET NO. <br /> OF CONCRETE COLUMN NOTES: <br /> INTO DROP CAP / PER PLAN <br /> FOR ADDITIONAL INFORMATION, REFEERENCE TYPICAL DETAILS S3 . <br /> 1 <br /> J <br /> TYPICAL DROP CAP 12 ANCHORAGE AT ENDS OF ADDED TENDONS 9 ANCHORAGE AT ENDS OF BANDED TENDONS 6 ANCHORAGE AT ENDS OF DISTRIBUTED TENDONS 3 <br />