My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1020 N BROADWAY 2019 Plans 2022-12-06
>
Address Records
>
N BROADWAY
>
1020
>
Plans
>
1020 N BROADWAY 2019 Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 1:22:35 PM
Creation date
8/4/2021 8:58:45 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1020
Permit
B1804-011
Year
2019
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> D O <br /> 0 0 <br /> LEGEND MILD REINF TO BE DIST - FOSSATTI PAWLAK <br /> W=COLUMN WIDTH WITHIN THIS AREA / DIST TENDONS <br /> H=SLAB THICKNESS PER PLAN gm STRUCTURAL ENGINEERS <br /> 1.5H / W / 1.5H / 1735 Westlake Ave N,Ste 205 <br /> Seattle,WA 98109 <br /> MILD REINF L1/6 L2/6 Phone:206.456.3071 <br /> PERO PLANW L1/6A Fax:206.456.3076 <br /> STAGGERED EW, o j www.fossatti.com <br /> TYP <br /> BANDED TENDONS CL SUPPORT CL SUPPORT <br /> ° ° PER PLAN, GROUP (5) <br /> / 1'-0"/ I TENDONS MAX <br /> ° ° CONC COL PER PLAN \ \ S S <br /> E. Q � 1 PAPS <br /> i 0 0 0 0 0 0 0 t o 0 0 0 0 0 o I N <br /> a. <br /> m Q - - P��pF SyI�lv�` <br /> o � <br /> a• _ S F�►�- ),,ek--- <br /> , <br /> i 0 0 0 0 0 0 04. n 0 0 0 0 0 0 1 El = L •1/3 / L 2/3 �0�� � ♦ ��� <br /> _ Cc, 23024 4I <br /> 7Ya'" / 3%"/ •/ -- . FN TORa� E `6\• ,,;:,, <br /> TYP TYP . ,. 4. �\ \ — — — SIONAL E` - <br /> S S 1, <br /> 0 0 0 0 0 0 0 s .% 0 0 0 0 0 0 0 I TOP UPPER ROOF <br /> o aJ> F/COL <br /> ALIGN STUDRAILS PER PLAN L1 L2 L3 <br /> TYP / / / / / / PROJECT <br /> END SPAN INTERIOR SPAN CANTILEVER SPAN <br /> / 4-3Y , -TOP LOWER REINF <br /> TYP — PER PLAN <br /> NOTES: <br /> NOTES: 0 01. MINIMUM OF (2) TENDONS SHALL BE PLACED DIRECTLY OVER COLUMNS, IN BOTH DIRECTIONS, UNO. <br /> 1. SR1 SHOWN. 2. FOR ADDITIONAL REINFORCING SEE TYPICAL POST-TENSIONED ANCHORAGE DETAILS. <br /> 2. SEE 11/S3.3 FOR SRX INFO. , O <br /> D O CO <br /> Q <br /> D O <br /> CD <br /> TYPICAL STUDRAIL LAYOUT 10 REINFORCING AT INTERIOR COLUMN 7 TYP POST-TENSIONED SLAB PROFILE - MILD REINFORCEMENT 1 0 <br /> oo -`a�—' <br /> "0 STUDS z <br /> O <br /> N W <br /> CONC COVER SHALL BE PT SLAB PER 0 <br /> THE SAME AS NOTED PLAN WHERE NO REINF IS CALLED FOR PROVIDE 2 #5 BARS MIN CONT LAP CL SUPPORT BEAM <br /> FOR SLAB REINF /"s" / UPPER REINF TOP BARS EQUAL IN AREA TOYAREA OF ( )T 18"" W/ TOP REINFOR COLUMN <br /> PLAN mPER PLAN BOTTOM BARS <br /> — [TOP <br /> BANDED TENDONS PER PLAN. EXTEND 2"-6""/ " Ya SPAN ""A" A / 1/3 OR"GRATER , 1/3 OR"GRATER / <br /> Q PL %x2 STUDRAIL GROUP (5) TENDONS MAX NDfE: IF POSSIBLE SPAN A OR B 1 SPAN A OR B# STUDS / RAIL / / ma- Z STRIP W/ SHEAR „(3) #5 x 8-0 LONG LAP CONT TOP BARS ® MID SPANLFIRST S T o oSTUDSEW BOT OVER COL & LAP CONT BOTTOM BARS <br /> / / ® SUPPORT — I., <br /> CONC COL 2" CLR UNIFORMLY DIST TENDONS REVISIONSP <br /> Tom_ MIN, T PER PLAN ; _ _ o <br /> STUDRAIL NOTES: PER PLAN o _ <br /> T SLAB <br /> 1. STUDRAIL HEIGHT IS DETERMINED BY THE THICKNESS OF THE SLAB ,�\ •• .. .• •• . -.• a �� w NO. DATE <br /> PER PLAN z <br /> HEIGHT MAY NEED TO BE ADJUSTED WHERE SLABS STEP OR SLOPE. W e A a °' <br /> 2. STUDRAILS AT COLUMN CORNERS SHALL BE ALIGNED WITH THE FACE PROVIDE (5) #3 STIRRUPS (MIN) <br /> OF COLUMN. INTERMEDIATE STUDRAILS SHALL BE EQUALLY SPACED. \ o co • (� EACH END OF BEAM. SPACE ® CL BEAM A -�- <br /> SUPPORT REINF DEPTH MAX FOR BALANCE OF BEAM PROVIDE 7/01/19 PERMIT REVISIONS <br /> 3. STUDRAIL SHEAR REINFORCEMENT SHOWN IN THESE DETAILS SHALL w o BY OTHERS #3 STIRRUPS SPACED CO BEAM DEPTH (18"" <br /> BE STUDRAILS AS MANUFACTURED BY "DECON". o MAX).zOTTOM BARS EXTEND 50% #4 @ 15 oc MAX EACH SIDE <br /> MAX FOR ADD L STIRRUPS SEE SCHEDULE. FOR BEAMS GREATER IN DEPTH <br /> 4. STUDRAILS TO MAINTAIN 1" CLEAR COVER TOP & BOTTOM FOR 3HR ¢ z CHAIR BY OTHERS ALL STIRRUPS SHALL BE GRADE 60 UNO. PAST THIS POINT BUT NOT i 9/17/19 PERMIT REVISIONS <br /> FIRE RATED SLAB �-= / / LESS THAN (2) BARS THAN 18" <br /> 5. STUDRAILS TO BE INSTALLED AT BOTTOM OF DROP CAPS, INCREASED -o I TOP LOWER REINF PROVIDE #3 STIRRUPS ® 6 oc ® BAR SPLICES 6" ,r <br /> HEIGHT REQ'D. PER PLAN MAX <br /> Y SPAN "A" <br /> -COL PER PLAN / <br /> NOTES: 2" MAX (2-6 MAX) <br /> / <br /> MARK 1ST SPACE "S" # STUDS/RAIL SPACE LTOTAL TOTAL # 1. ALTERNATE TENDON AND REINFORCING GROUPS. TO FIRST <br /> S"` L STUD RAILS 2. FOR QUANTITY AND LENGTH OF REINFORCING, REFERENCE PLAN. STIRRUP SPAN "A" SPAN "B"3. FOR REINFORCING STAGGER, REFERENCE TYPICAL DETAILS. ....... <br /> SR1 3% 7 7Y4 4'-3Ya 10 4. MINIMUM OF (2) TENDONS SHALL BE PLACED DIRECTLY OVER <br /> SR2 37/8 12 4Y2 4'-9Ya 10 COLUMNS IN BOTH DIRECTIONS, UNO. <br /> SR3 37/8 7 5% 3'-6Y 5 <br /> SR4 3) 15 3Y 4'-8" 5 <br /> TYPICAL STUDRAIL SECTION 11 SECTION THRU BANDED TENDONS AT SUPPORT 8 TYPICAL CONCRETE BEAM REINFORCING 2 <br /> 5/28/19 19-042 <br /> DATE JOB# <br /> TCB FPP <br /> GRID DESIGN CHECKED <br /> BDS AS NOTED <br /> + BANDED TENDONS PER PLAN. WHERE (3) OR MORE SINGLE DRAWN SCALE <br /> GROUP (5) TENDONS MAX <br /> CONDUIT OCCUR, PROVIDE REINF <br /> 1 TOP UPPER REINF NOTES: FOR CONDUIT GROUP <br /> PER PLAN 1. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS INDICATING PLACEMENT OF CONDUIT <br /> IN POST-TENSIONED SLAB (SEE GENERAL STRUCTURAL NOTES). LOCATE CONDUIT IN <br /> PT SLAB & REINF BANDED TENDON Q x 2" CLR // UNIFORMLY DIST 2. SEE DIAGRAM ABOVE FOR CONDUIT PLACEMENT RESTRICTIONS. PROVIDE MIDDLE THIRD OF SLAB t/6 0 HOLES (MAX) <br /> MIN, TYP TENDONS PER PLAN REINFORCING AS REQUIRED IN DIAGRAM. CONDUIT PLACEMENT NOT MEETING CRITERIA DEPTH <br /> PER PLAN PER PLAN Q T SLAB \ <br /> w SHOWN IN DIAGRAM SHALL BE SUBMITTED TO ENGINEER FOR REINFORCING DESIGN. #4 ® 12""oc TOP & BOT <br /> I a—d -11F PER PLAN c, z¢ 3. DO NOT PLACE CONDUIT WITHIN A DISTANCE EQUAL TO THE SLAB DEPTH FROM T <br /> L1 _J a 4. a COLUMN FACE. <br /> r: \ * - - 3 CONDUIT MAX IN <br /> o m EACH GROUP <br /> N CHAIR BY OTHERS <br /> 't-, o \ <br /> . CDZ SUPPORT REINF <br /> ,` BY OTHERSV• <br /> • o TOP LOWER REINF 0� m m m m m SHEET TITLE <br /> -0 <br /> 1" PER PLAN \ \ <br /> 2 11 <br /> / <br /> (3) #5 x 8'-O" LONG \ <br /> EW BOT OVER COL <br /> NOTE: TYPICAL <br /> SOFFIT SLOPE IN LIEU OF STEP AT CONTRACTOR'S OPTION. NOTES: COL PER PLAN ��(1) CONDUIT <br /> 1. ALTERNATE TENDON AND REINFORCING GROUPS. DIAMETER MIN PT DETAILS <br /> 2. FOR QUANTITY AND LENGTH OF REINFORCING, REFERENCE PLAN. (3) CONDUIT / / 77 <br /> 1 -O" / /(3) CONDUIT <br /> 3. FOR REINFORCING STAGGER, REFERENCE TYPICAL DETAILS. DIAMETER MIN DIAMETER MIN <br /> 4. MINIMUM OF (2) TENDONS SHALL BE PLACED DIRECTLY OVER <br /> COLUMNS IN BOTH DIRECTIONS, UNO. SINGLE CONDUIT <br /> CONDUIT GROUP <br /> SHEET NO. <br /> S3 . 3 <br /> T <br /> TYPICAL SLAB STEP < 0'-4" 12 SECTION THRU DISTRIBUTED TENDONS AT SUPPORT 9 CONDUIT PLACEMENT CRITERIA AT PT SLAB 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.