ALL EXPOSED H.W. PIPES
<br /> '� �P
<br /> SHALL BE INSULATED- MIRROR ACCESSIBILITY NOTES -TYPE A UNITS
<br /> 2'-6"MIN PIPE SLEEVES TO HAVE
<br /> CONTROLS - LOWERED WORK / PROVIDE NON-ABRASIVE SURFACE 1'-6" 2'-0" 1. ALL FIXTURES, DIMENSIONS &CLEARANCES TO COMPLY WITH ANSI Al 17.01, 2017 EDITION AND 2012 SBC
<br /> SHALL BE SURFACE WITH KNEE CLR BACKING FOR
<br /> MW/VENT MAX. 46" SPACE PROVIDED TOWEL RAIL FINISHED PROVIDE /j CHAPTER 11. THE DIAGRAMS INCLUDED HEREIN ARE TYPICAL CLEARANCES FOR REFERENCE ONLY.
<br /> A.F.F. PANEL REMOVABLE N MIN \ REFER TO ARCHITECTURE PLANS AND ENLARGED PLANS FOR PROJECT SPECIFIC INFORMATION.
<br /> PROVIDE \ CABINETRY UNDER o o
<br /> - REMOVABLE " 1-1-1 LAVATORY 1 - GENERAL
<br /> O
<br /> RANGE / 2 _0 / CABINETRY z Q rn \ I
<br /> --_._ SHALL CONTROLSBE 1 z w©-- 1" - \ J I Co 1. LAUNDRY AREA SHALL PROVIDE A CLEAR FLOOR SPACE POSITIONED FOR A PARALLEL APPROACH.
<br /> _Nvz ! LLi \); \ OPERABLE PARTS SHALL BE OPERABLE W/ONE HAND & NOT REQUIRE TIGHT GRASPING, PINCHING, OR
<br /> FRONT Z , I o U� in z 16" =x xx OD_ ~ v XX \Z �-/ \ IP I �,[11 TWISTING OF THE WRIST.
<br /> MOUNTED �- oo � IL ¢ Z O 6 MAX Q U Q O - . I I o'
<br /> Z i I I "v v Cm O < 8 MIN b w Z0'-8" c) 147,1
<br /> _ I 1 ¢ v 'g o_ '� TOE CLR o g a <"" > 1 C 2. TOP LOADING WASHING MACHINES SHALL HAVE A DOOR NO MORE THAN 36"AFF. FRONT LOAD MACHINES
<br /> 0 1 •1 Y M Q 11 ' MIN CJ w D co - Q -- i - I I Z SHALL HAVE THE BOTTOM OF THE OPENING BETWEEN 15"AND 34"AFF.
<br /> M� X o I I Z N O KNEE ? op c� p 1 OPERATION PER 309.4:
<br /> Mill MIN N Ilibk L_ `� 0° CLR � � m �`�" 30" MIN. ! OPERABLE PARTS SHALL 3. LIGHTING CONTROLS,APPLIANCE CONTROLS, PLUMBING FIXURE CONTROLS AND SECURITY/INTERCOMN \ \ \ \ BE OPERABLE WITH ONE HAND SYSTEMS SHALL BE INSTALLED BETWEEN 15"AFF &48"AFF. CONTROLS SHALL BE OPERABLE WITH ONE
<br /> \ �� \ CLEAR FLOOR SPACE AT 17"MIN _ FINISH WALL jr 30"MIN CLR AND SHALL NOT REQUIRE TIGHT HAND AND NOT REQUIRE TIGHT GRASPING OR TWISTING.AT LEAST ONE WINDOW IN EACH LIVING, SLEEPING,
<br /> 7 FINISHED PANEL / 2'-6" MIN WORK SPACE TO MATCH GRASPING OR TWISTING OF THE AND DINING SPACE SHALL BE OPERABLE PER ABOVE.
<br /> FINISH WALL TO MATCH / FORWARD APPROACH 25 MAX
<br /> WRIST. THE FORCE REQUIRE TO
<br /> (36"MIN IF PART EXTEND FINISH CLEAR FLOOR SPACE ACTIVATE OPERABLE PARTS
<br /> PROVIDE CLEAR SPACE EXTEND FINISH FLOOR UNDER OF A T-SHAPED TOWEL RAIL LAVATORY VANITY (HIGHEST OPERABLE PORTION OF THE OPERABLE PART"MUST BE" LOCATED WITHIN REACH RANGE.)
<br /> FOR FRONT OR PARALLEL REMOVABLE CABINETRY FLOOR UNDER LAVATORY CLEARANCES AT LAVATORIES SHALL
<br /> APPROACH TURNING SPACE) LAVATORY BE 5.0 POUNDS MAX. KITCHEN
<br /> WORK SURFACE CABINETRY
<br /> OCLEARANCES @TYPE A UNIT-LAVATORY 1. RANGE& OVEN CONTROLS TO BE LOCATED ON THE FRONT PANEL OF THE APPLIANCE. PROVIDE WALL
<br /> 3/8" = 1'-0" MOUNTED SWITCH (34-36"AFF) FOR RANGE HOOD CONTROLS.
<br /> 2. OPERABLE PARTS SHALL BE LOCATED BETWEEN 15"AND 48"VERTICALLY FROM FLOOR AND PROVIDE CLEAR
<br /> - PROVIDE BACKING FLOOR SPACE.
<br /> SHOWER SPRAY UNIT W/59" HANDHELD FOR GRAB BARS
<br /> c. MIN LENGTH HOSE AND SHOWERHEAD IN PER CODE, DO NOT 3. ALL OPERABLE CONTROLS WITHIN ELECTRICAL PANEL BOARDS SHAL BE WITHIN REACH RANGE. THESE
<br /> LOWERED WORK CAN BE USED FIXED OR ITS LOWEST PROVIDE AT SEAT ALIGN END OF GRAB CONTROLS ARE NOT REQUIRED TO MEET THE MAX. 5LB OPERATING FORCE.
<br /> (60" MIN. IN SURFACE. EQ ( EQ HANDHELD WITH SLIDING BAR 27"MAX POSITION TO BE WALLS BAR
<br /> U-SHAPED AND 7 / E OF SEAT
<br /> PROVIDE OR APPROVED EQUAL 48" MAX ABOVE I�," WIT22" 23"' 3. ALL APPLIANCE CONTROLS SHALL BE OPERABLE W/ONE HAND & NOT REQUIRE TIGHT GRASPING, PINCHING,
<br /> DEAD-END FLOG' PROVIDE ��( I I OR TWISTING OF THE WRIST. RANGE AND OVEN CONTROLS TO BE LOCATED ON THE FRONT PANEL OF THE
<br /> KITCHENS) CABINETRY \ i \ \ PROVIDE CONTROLS BACKING CO I I APPLIANCE.
<br /> WITH CABINETS, PROVIDE �\ - BACKING FOR FOR SEAT ��
<br /> LJCOUNTERTOPS OR „ REMOVABLE T g 0 0 ~ GRAB BARS SHOWERAND D 16"MIN PER CODE ' Z w 4. PROVIDE WALL MOUNTED SWITCH (34-36"AFF) FOR RANGE HOOD CONTROLS.
<br /> APPLIANCES ON 3 2 -0CA M PER CODEI v -- D. i
<br /> CONTIGUOUS SIDES / UNDER SRNK Y b1 1 \ Z LOCATION GRAB BAR REQ'D " I 4), w BATH
<br /> ? WHERE SHOWERX
<br /> I \ 1 I � FOLDING lIi N I.L
<br /> I 1 0 \ WIDTH IS LESS I, SEAT u1 O O 1. PROVIDE REINFORCEMENT FOR FUTURE INSTALLATION OF GRAB BARS AND SHOWER SEATS. ••
<br /> 3'-4" MIN 1 I EXTEND GRAB THAN OR EQ, TO I I Z
<br /> / / 0'-8\?,--i
<br /> I BAR FULL 72 - - u- GRAB BAR NOTES
<br /> / • r`ri ' INSULATE EXPOSED ALL I 1 LENGTH OF / ��/�A \PERMITTED Z Q .
<br /> MIN \ SHOWER1 I Z m 1. GRAB BARS SHALL BE 1.5-2" IN DIAMETER SPACE BETWEEN GRAB BAR, WALL, AND PROJECTING OBJECTS
<br /> �- (MAX( z LAVATORY PER I 15' 16" •o g
<br /> iv H.W. jr 2'-6"MIN REQUIRED /- 0'-6"MAX = _ �a 1 CO J BELOW SHALL BE 1.5"MIN SPACE BETWEEN GRAB BAR AND PROJECTING OBJECTS ABOVE SHALL BE 12"
<br /> I \ I \, PIPING / LENGTH = 30") M M b rr//// % N LAVATORY NIT H. - - 2 1/2"MAX i M "' O MIN.
<br /> ALIGN END OF
<br /> 2 -6 MIN 0'-6" MAX M GRAB BAR WITH M ' IJrAIp
<br /> z DRAWINGS I MINIMUM FINISHED / FINISH WALL TO MATCH / CLEAR FLOOR SPACE EDGEOFSEAT = M `Y' 2. LOCATE GRAB BARS 33%36"AFF TO T.O. GRIPPING SURFACE. EXCEPTIONS PERMITTED BY VERTICAL GRAB
<br /> CLEARANCE PANEL (36" MIN IF PART AT SINK FORWARD APPROACH BARS AND ANSI 607 GRAB BARS &ADJACENT WALLS SHALL HAVE ROUNDED EDGES AND BE FREE OF '
<br /> 24"MAX EXTEND FINISH FLOOR UNDER OF A T-SHAPED NOTE: �� \ \ / 36"CLR MIN A SHARP OR ABRASIVE ELEMENTS.
<br /> REMOVABLE CABINETRY
<br /> TO REAR TURNING SPACE) DISHWASHER DOOR 60" MIN. Permit Set
<br /> ONTROLS KITCHEN SINK CABINETRY WHEN SIDE WALL BACK WALL SEAT WALL / / 3. GRAB BARS, FASTENERS&SUPPORTING STRUCTURE SHALL WITHSTAND 250 LBS MIN FORCE.
<br /> OPEN MAY NOT 30 X 60 IN. INSIDE CLEAR MINIMUM ROLL-IN STALL SHOWER SEAT NOTES B 1804-011
<br /> J . 1 24"MIN OVERLAP 30 X 60 IN. SHOWER STALL ELEVATIONS 1/2 IN. CURB MAX. W/ 1:2 BEVEL
<br /> — XQ w 0 x w CLEAR FLOOR SPACEcT3 1. FOLDING SHOWER SEAT TO BE PROVIDED ADJACENT TO CONTROL WALL.
<br /> w , � ¢ � I @SINK
<br /> 2 w z to Q w Q CLEARANCE @ TYPE "A" UNIT-ROLL IN SHOWER 2. HEIGHT TO BE 17-19"ABOVE BATHROOM FLOOR TO TOP OF SEAT.
<br /> v O .1 U v p o- I , -- ELECTRICAL- 3/8" = 1'-0"
<br /> 3. SEAT SHALL EXTEND ALONG THE WALL TO WITHIN 3" OF ENTRY.
<br /> ♦ \ I \ T- REGISTERED
<br /> 15" MIN - ♦ r i I 4. REAR EDGE OF SEAT SHALL BE 2.5" MAX FROM SEAT WALL. ARCHITECT
<br /> ALL OPERABLE PARTS ° _ I _ _ _ _r r No.sops
<br /> OPERABLE PARTS REACH RANGE I I io 1 I z I Z I C%t/G�
<br /> I I I I I 1 I 2 Z I 5. FRONT EDGE OF SEAT SHALL BE 15-16" FROM SEAT WALL
<br /> Joshua S.Scott
<br /> I 1 = I 48„ I 32"CLR 1 •ao 11'- 10" �° N 1 2'-0" I 6. SIDE EDGE OF SEAT SHALL BE 1.5" FROM CONTROL WALL.
<br /> I I I ♦ `� 1 �� d i IIMI 1/2'
<br /> STATE OF WASHINGTON
<br /> �"� T MIN I MIN I 7. SEAT, FASTENERS &SUPPORTING STRUCTURE SHALL WITHSTAND 250 LBS.
<br /> Will) } - - - - - � - - I „ "
<br /> ♦ Li in Z j, 30 1
<br /> 4- 00 Q 4- 2 I— I I FRONT APPROACH POCKET OR STOP OR LATCH
<br /> / 4'- 0" MIN / ♦ ♦ HINGE APPROACH APPROACH
<br /> ♦ • iO
<br /> 1 ' MANEUVERING CLEARANCES AT DOORS-SLIDING AND FOLDING DOORS
<br /> z I I 'to to CLEAR FLOOR ELECTRICAL PANEL CLEARIFLOOR NOTE:
<br /> I 24"MAX I Tr
<br /> SPACE MOUNTING HEIGHT SPACE 1'-0" MIN 1'-0" MIN - FOR DOORS IN ALCOVES SEE
<br /> b �' m @ REFRIGERATOR- @ ELECTRICAL / IF BOTH LATCH & r IF BOTH LATCH & 2'-0"
<br /> ICC A117.1-2009
<br /> co I I I d' -4 PARALLEL PANEL- PARALLEL - MANEUVERING CLEARANCES
<br /> I APPROACH APROACH & CLOSER PROVIDED CLOSER PROVIDED / /
<br /> ♦ . + j ♦ T T MIN NOT REQUIRED AT THE
<br /> FRONT APPROACH ' 1 w = 0 I 1 r 1 o INTERIOR
<br /> y 48"MIN X 2' 0" X I 1 Z U w I
<br /> 1 I 1 z w co w OF NON-ACCESSIBLE BATHS
<br /> 1 1 I 2 Z ~ � P I 1 1 I - � - OR
<br /> REACH RANGE MIN o I I - F 5 O > I I I I o O >
<br /> @ I I M o = -' O i 22"MIN r0 I is 4 _, 0 THE OUTSIDE OF NON-PRIMARY •
<br /> CLEAR FLOOR SPACE @ FRONT LOADING �* I �. ~O V a I Xiti
<br /> I I Z., 0 a EXTERIOR DOORS WHERE
<br /> FRONT LOADING W/D UNITS W/D UNITS I coI I I BALCONIES DO NOT PROVIDE 24"MAX
<br /> 0 0 0 0 REQUIRED MANEUVERING l'ie / •
<br /> CLEARANCE PERMITTED LAVATORY '
<br /> PER TYPE"A"UNIT
<br /> LAVATORY DRAWINGS
<br /> 4
<br /> . 0 0 0 0 SINGLE LEAF MUST PROVIDE r I \
<br /> r - - -, \ 32"CLEAR OPENING
<br /> FORWARD APPROACH I I �,� 4' 0" MIN z
<br /> NOT ALLOWED OVEN 1 = PUSH SIDE PUSH SIDE PUSH SIDE �y 39" 41" z
<br /> Wi'D @ 1 I co z FRONT APPROACH HINGE APPROACH LATCH APPROACH 'I
<br /> ,_ & RANGE I I m �4'-6"MIN k '
<br /> 12"MIN IF LAVATORY
<br /> 1 NI MANEUVERING CLEARANCES AT DOORS- INSWINGING DOORS I OVERLAPS
<br /> RSPACE \ 12"MAX 1 CV
<br /> % I CLEAR \j 42 MIN / / L
<br /> 1 I L J \ I 1 r 1 \ OPENING ;2"MIN 24" MIN BCKINGFOAB BARS a \ DISPENSER
<br /> PER CODE LOCATION \
<br /> 0 ro -1 , \ ,
<br /> I I = Gp — I 1 6" MIN I I Z 1 V I — `` — —
<br /> Z 0 I C`_"�""""� \ \- \ \\ '- "' \� Z • NO FIXED
<br /> CO M C) W I SUPPORT I Z
<br /> I I 1 ch �t H 4'-0" MIN - 12'-0" I = zwo a1 = z
<br /> I 1 / / o �,I,pREFERRED 1 o = > I tO v \ io ao U
<br /> ♦ ♦ ♦ FORWARD 'Co 3'-6"MIN 1 _' 36"MIN 1 in , m 0 24"MIN Mg co iv z�\ co r-\ 10 _( o
<br /> _ , o
<br /> CLEAR FLOOR I v n- = M - 1 / io
<br /> 48"MIN APPROACH SPACE @ I -o MAX E.
<br /> NOT ALLOWED @ \ \ TI
<br /> REACH RANGE @OVEN & o m T 1 a0
<br /> CLEAR FLOOR SPACE @ TOP LOADING W/D UNITS REFRIGERATORR DISHWASHER 32"MIN \ _''r-;"�_'' \ \ �e�� \
<br /> OR DISHWASHER PULL SIDE PULL SIDE PULL SIDE PULL SIDE/ il,
<br /> TOP LOADING W/D UNITS PARALLEL FRONT APPROACH HINGE APPROACH HINGE APPROACH LATCH APPROACH FLUSHNOTE Hc.w.cO / 24"MIN / 66"MIN # DATE DESCRIPTION
<br /> CONTROLS SHALL
<br /> It 0
<br /> APPROACH 1' 6" 18"CLR ALWAYS BE OPPOSITE TO
<br /> 2'-6" MIN MANEUVERING CLEARANCES AT DOORS-OUTSWINGING DOORS -/ / / NEAREST WALL 42L,MAX/ / 'tL �,1IW\ /
<br /> 7
<br /> f_ CLR
<br /> CLEARANCES�a MAIN ENTRY CLEARANCES @TYPE A UNIT-WATER CLOSET
<br /> INSULATE
<br /> 4 ; 1/4" = 1'-0" © 3/8" = 1'-0"
<br /> PROTECT
<br /> 0 I 0 \ -0-1 0 \ UNDERSIDE OF SHOWER SPRAY UNIT W/ 59" MIN. CLEAR INSIDE DIM. DEVELOPMENT
<br /> i,- COOKTOP TO LENGTH HOSE THAT CAN BE USED OF 36"X36" SHOWER SPRAY
<br /> PROVIDE FIXED OR HANDHELD WITH SLIDING MEASURED @ UNIT T HOSE MIN. 4" MAX NOTE:ALL GRAB BARS & SEATS SHOWN FOR 1830 BICKERED AVE,
<br /> I z PREVENT BURNS ILLUSTRATION ONLY SUITE 201
<br /> Z AND SHOCKS BACKING FOR BAR OR APPROVED EQUAL CENTER POINT LENGTH
<br /> I 1 \ 2 I Z SNOHOMISH, WA 98290
<br /> \ GRAB BARS PER THAT CAN BE 24"MIN
<br /> a, OF EACH SIDE
<br /> I I o I 8" . CODE, DO NOT USED FIXED OR 12"MAX 15" MAX---
<br /> 206.755.1290
<br /> Zo PROVIDE AT CONTROLS & HANDHELD WITH n pQ
<br /> z I co MIN -SEAT WALLS HAND SHOWER BACK WALL SLIDING BAR OR
<br /> 1 / / / / 121/16" 15"
<br /> I ' I l -(-J Z
<br /> %ram'
<br /> N t LOCATION QQ n J w APPROVED EQUAL u PROVIDE TMAXT MAX -
<br /> I I FINISH WALL TO I
<br /> I J Q PROVIDE �j►�l j GRABI BAR FOR
<br /> PROVIDE Q ;��/ \ SEAT
<br /> \ \ MATCH PROVIDE _1 ,�i►. Z
<br /> BACKING BACKING P I- C O BACKING !IL
<br /> 1 -- PER CODE 1020 North Broadway
<br /> EQ I EQ EQ EQ EXTEND FINISH FLOOR FOR SEAT PER0FOR GRAB I io
<br /> iGFORGRAB -
<br /> / X / / X / BARSPER � 1�.�� O . , .. — — — — NCODE „% w z \ 0 12„ Everett, WA 98403
<br /> FINISHED PANEL , ��,ie BARS PER _„ CODE %i � VCODE N . � �� C-1 / ��j���/ \ MIN \4 -0 2 -6 = s..
<br /> / / / / CABINETRY AT / C� 'C \ M ,riiiii rii�\iiir�ii�iiiiii / Z I I Z
<br /> MIN MIN
<br /> jj�j��j r/�/e�������%� �� ����� I Z `° 2 I 1 ACCESSIBILITY DETAILS -TYPE
<br /> FORWARD APPROACH FOLDING OR NON- I I o c� a, \� _ \ M I I = "A" UNIT
<br /> CLEAR FLOOR SPACE 1 CLEAR FLOOR SPACE 2 ����������� FOLDING SEAT I I co1111 co �_ I I (O
<br /> SHALL BE PROVIDED I CONTROLS o b I I N
<br /> @ COOKTOP PARALLEL @ COOKTOP FORWARD j /�j� / THEO CONTROL WAOSITE I LOCATION
<br /> I I
<br /> APPROACH APPROACH NOTE: I 48"MIN \ L _J \
<br /> 1)ALL RANGE&COOKTOP CONTROLS SHALL BE LL i L
<br /> LOCATED FORWARD OF BURNERS IN TYPE "A" — 6" J/ /� 6 MAX / 60" MIN /
<br /> UNIT KITCHEN APPLIANCES KITCHENS `6" DATE: Issue Date
<br /> 2) FOR OUTLETS ABOVE COUNTERTOP COMPLY W/ SEAT WALL BACK WALL CONTROL WALL CONTROL WALL BACK WALL PLAN
<br /> 3)ALL APPLIANCES MUST MEET AT LEAST ONE OF
<br /> THE CLEAR FLOOR SPACES SHOWN FOR THAT 36 X 36 IN.SHOWER STALL ELEVATIONS 36 X 36 IN. SHOWER STALL
<br /> APPLIANCE TYPE"A" 1/2 IN. CURB MAX. 30 X 60 IN. TUB WITH PERMANENT SEAT ELEVATIONS
<br /> •
<br /> SHEET:
<br /> O 3 O. CLEAORANCES @ TYPE A-KITCHEN CLEARANCES @ TYPE A UNIT TRANSFER SHOWER CLEARANCES @ TYPE A UNIT TUB W/SEAT AO . 06 '
<br />
|