Laserfiche WebLink
PER ICC A117.1 ` :- $ O <br /> 1104.11.1 24"MAX se <br /> ACCESSIBILITY NOTES -TYPE B UNITS <br /> c_ REINFORCEMENT <br /> SHALL BE 1. ALL FIXTURES, DIMENSIONS &CLEARANCES TO COMPLY WITH ANSI A117.01, 2009 EDITION AND 2012 SBC <br /> PROVIDED FOR 2 2 CHAPTER 11. THE DIAGRAMS INCLUDED HEREIN ARE TYPICAL CLEARANCES FOR REFERENCE ONLY. REFER <br /> i THE FUTURE _ _ - TO ARCHITECTURE PLANS AND ENLARGED PLANS FOR PROJECT SPECIFIC INFORMATION. <br /> INSTALLATION OF 42" MIN. IF WALL v c, <br /> p GRAB BARS SPACE PERMITS 1 GENERAL <br /> ��� \ e ` z . 1. LAUNDRY AREA SHALL PROVIDE A CLEAR FLOOR SPACE POSITIONED FORA PARALLEL APPROACH. <br /> g OPERABLE PARTS SHALL BE OPERABLE W/ONE HAND & NOT REQUIRE TIGHT GRASPING, PINCHING, OR <br /> I �' M M z z _ _ TYPE A& B UNITS MIN TO LOWEST HIGHEST OPERABLE <br /> _ ' i c k' ELECTRICAL PANEL RECEPT. PART OF SWITCHES NOTES: TWISTING OF THE WRIST. <br /> `r' iN 19" M MMIIIM 'EN c" M ao UVQ OR THERMOSTATS 1. HEIGHT IS MEASURED TO LAVATORY RIM OR 2. TOP LOADING WASHING MACHINES SHALL HAVE A DOOR NO MORE THAN 36"AFF. FRONT LOAD MACHINES <br /> cn I MAX `n W i COUNTER SURFACE, WHICHEVER IS HIGHER. SHALL HAVE THE BOTTOM OF THE OPENING BETWEEN 15"AND 34"AF <br /> L ��- in 2. INSULATE ALL EXPOSED PIPES UNDER LAVATORY <br /> • 1'-6"),/ TOP56"MINO ACCESSIBILE WALL SWITCHES 3. FAUCETS SHALL NOT REQUIRE TIGHT GRASPING, KITCHEN <br /> jr OF 3/8" = 1'-0" PINCHING OR TWISTING. <br /> CLR SEAT 65" MIN FOR FWD APPROACH 1. RANGE &OVEN CONTROLS TO BE LOCATED ON THE FRONT PANEL OF THE APPLIANCE. PROVIDE WALL <br /> 33"MIN 30" MOUNTED SWITCH (34-36"AFF) FOR RANGE HOOD CONTROLS. <br /> NOTE: c_ ON LAVATORY s i / / BRACKET- <br /> EXEPTION: 18 1/16" <br /> AT WATER CLOSETS WHERE A SIDE WALL IS NOT AVAILABLE FOR A 42 IN. GRAB ALL LAVATORIES IN "M" / 17"MIN SUPPORTED 2. OPERABLE PARTS SHALL BE LOCATED BETWEEN 15"AND 48"VERTICALLY FROM FLOOR AND PROVIDE CLEAR <br /> BAR, REINFORCEMENT FOR A FOR A SWING UP GRAB BAR SHALL BE BATHROOMS SHALL MEET 24" 24" COUNTERTOP FLOOR SPACE. <br /> PERMITTED. PARALLEL APPROACH MIN I MIN SUPPORT <br /> REQUIREMENTS SHOWN _ 3. ALL OPERABLE CONTROLS WITHIN ELECTRICAL PANEL BOARDS SHAL BE WITHIN REACH RANGE. THESE <br /> 0• r- BRACKETS CONTROLS ARE NOT REQUIRED TO MEET THE MAX. 5LB OPERATING FORCE <br /> CLEARANCE @UNIT B WATER CLOSET 2 2 <br /> O 3/8" = 1'-0" N a- INI <br /> N 1 BATH <br /> A <br /> I •` z Q I i L /;%�% 1. PROVIDE REINFORCEMENT FOR FUTURE INSTALLATION OF GRAB BARS AND SHOWER SEATS. <br /> p I <br /> ~-`� I I III <br /> ill <br /> i 1\\%,� g GRAB BAR NOTES2 ir kr ��_ I o 0 \% vc.� I ,����11 I ch u i I ' I I L co 1. GRAB BARS SHALL BE 1.5-2" IN DIAMETER SPACE BETWEEN GRAB BAR, WALL,AND PROJECTING OBJECTS <br /> =_ z I I BELOW SHALL BE 1.5 MIN SPACE BETWEEN GRAB BAR AND ROJECTING OBJECTS ABOVE SHALL BE 12" MIN. <br /> 0 p M - <br /> 36 I IIIIL- 4,io - 19"MAX CLEAR 2. LOCATE GRAB BARS 33"-36"AFF TO T.O. GRIPPING SURFACE. EXCEPTIONS PERMITTED BY VERTICAL GRAB <br /> MW/VENT NOTE: EQ EQ 48"MIN CLR 48"MIN `o L I _ _ - 1 48' 'f- KNEE BARS AND ANSI 607 GRAB BARS &ADJACENT WALLS SHALL HAVE ROUNDED EDGES AND BE FREE OF <br /> FRONT ALL APPLIANCES MUST MEET FLOOR SPACE 48"MIN SPACE SHARP OR ABRASIVE ELEMENTS. <br /> MOUNTED AT LEAST ONE OF THE CLEAR <br /> FLOOR SPACES SHOWN FOR <br /> 3. GRAB BARS, FASTENERS &SUPPORTING STRUCTURE SHALL WITHSTAND 250 LBS MIN FORCE. <br /> CONTROLS 2'-0" 7- �� CLEAR FLOOR SPACE AT LAVATORIES CLEAR FLOOR SPACE AT LAVATORIES- <br /> PREFERRED / \ THAT APPLIANCE TYPE 0 PARALLEL APPROACH FORWARD APPROACH SHOWER SEAT NOTES <br /> I \ 4 CLEARANCES @ TYPE B UNIT-LAVAROTY 1. FOLDING SHOWER SEAT TO BE PROVIDED ADJACENT TO CONTROL WALL. <br /> 0 0 z 3/8" = 1'-0" 2. HEIGHT TO BE 17-19"ABOVE BATHROOM FLOOR TO TOP OF SEAT. <br /> 2 <br /> co C° `° 3. SEAT SHALL EXTEND ALONG THE WALL TO WITHIN 3" OF ENTRY. <br /> M iv 12"MIN IF BOTH LATCH &CLOSER y12" IF BOTH LATCH &CLOSER 24" <br /> 1 1 ,� L \ '� i PROVIDED MIN PROVIDED 4. REAR EDGE OF SEAT SHALL BE 2.5" MAX FROM SEAT WALL. <br /> •48"MIN �- ctsTI MIN <br /> 1_____ 4 -0"MIN = p I I w p CLEA 5. FRONT EDGE OF SEAT SHALL BE 15-16" FROM SEAT WALL. <br /> CLEAR FLOOR SPACE / / Z 1 I ? - U w I I z O o R Permit Set <br /> PROVIDE CLEAR SPACE FOR I I - I - v j OPENI 6. SIDE EDGE OF SEAT SHALL BE 1.5" FROM CONTROL WALL. <br /> PARALLEL APPROACH PER CLEAR FLOOR SPACE AT SINK- o I C° OJ O I 22"MIN ' ll 1 1 zo " ° NG B 1 804-011 <br /> CABINETRY AT SINK PARALLEL APPROACH I I o = I I I <br /> DWG/SHT PARALLEL APPROACH r- in ' I- U t Jr Jr c, a_ 7. SEAT, FASTENERS &SUPPORTING STRUCTURE SHALL WITHSTAND 250 LBS. <br /> I I tJ a I 1 I I M I <br /> ca <br /> / 32"MIN <br /> 'f y <br /> • <br /> CLEAR OPENING INTERIOR i EXTERIOR INTERIOR EXTERIOR <br /> I iv 3/4" MAX @ SECONDARY REGISTERED <br /> PUSH SIDE PUSH SIDE PUSH SIDE i� I / 1!2" MAX. W/ `' SLIDING GLASS DOOR W/1:2 \'' ? <br /> ARCHITECT <br /> 25 1/2" MAX <br /> EQ EQ <br /> / FRONT APPROACH HINGE APPROACH LATCH APPROACH PRIMARY ENTRY DOOR 1:2 BEVEL 2 I 2 <br /> 1 1--- � 1 BEVEL No.8013 <br /> i (%�/G?�� <br /> uouN I tK REMOVABLEM PROVIDE <br /> DEPTH I MANEUVERING CLEARANCES AT PRIMARY ENTRY DOOR- INSWINGING DOORS <br /> 2'-0^ / CABINETRY I� \ ` <br /> UNDER SINK r I- <br /> I -Iill i Joshua S.Scott <br /> PREVIOUS CONSTRUCTION STATE OF WASHINGTON <br /> 0I I I I <br /> i 0,- <br /> T 1 I °' I 0 I I I IMPERVIOUS CONSTRUCTION <br /> L ►���� VV VVV <br /> �- �\ \ I z I I i z I - I g g - w o i /h SECONDARY Ca ENTRY <br /> 40" MINt ' N ' pzil I I I b 18' 2'- 0" PREFERRED 42"MIN b _ - I <br /> .i, `� <br /> (60" MIN. IN z 8, `,�'_ , i I in MINI I ` 36"MIN io U 24" <br /> U � <br /> U-SHAPED / / w co 1 `t -v a MIN I <br /> MIN M EXPOSED H.W. `"' I I INTERIOR I EXTERIOR INTERIOR EXTERIOR NOTE: <br /> KITCHENS) = y PIPING wiA <br /> i I I I I <br /> I ,� I <br /> \ I PEDESTAL PAVERS DO <br /> WITH CABINETS, 30" <br /> PULL SIDE PULL SIDE PULL SIDE PULL SIDE I 1 1:22 BEVEL' MAX. W/ I NOT COMPLY WITH <br /> FINISH WALL TO MATCH 2'-6" MIN FRONT APPROACH HINGE APPROACH A HINGE APPROACH B LATCH APPROACH iN IMPERVIOUS <br /> COUNTERTOPS OR FINISHED MIN / / C � <br /> 1/2" BEVEL CONSTRUCTION LEVEL <br /> EXTEND FINISH FLOOR <br /> APPLIANCES ON 3 PANEL / <br /> CONTIGUOUS SIDES MANEUVERING CLEARANCES AT PRIMARY ENTRY DOOR- OUTSWINGING DOORS MAX CHANGE <br /> UNDER NOTE: PERVIOUS CONSTRUCTION IMPERVIOUS CONSTRUCTION REQUIREMENTS. <br /> REMOVABLE CABINETRY CLEAR FLOOR SPACE AT SINK- 1. FOR PRIMARY ENTRY DOOR IN AN ALCOVE SEE ICC A117.1-2009 <br /> MINIMUM CLEARANCE CABINETRY AT SINK- FORWARD APPROACH FORWARD APPROACH REQUIRED INTERIOR & EXTERIOR 2. CLEARANCES REQUIRED AT EXTERIOR AND INTERIOR OF PRIMARY <br /> ENTRY DOOR. PRIMARY a ENTRY <br /> c_ 3. SINGLE LEAF MUST PROVIDE 32" CLEAR OPENING FOR ALL <br /> PASSAGE DOORS. <br /> t <br /> MIN / / 4'-0" MIN / CLEARANCES @ TYPE B-OPENINGS 7 FLOOR TRANSITION@ TYPE "A"&"B" UNIT c.. _ <br /> 2' - 0" MIN �� _ �_0�� �� �� <br /> / " 1/4 1 1 1/2 = 1 0 I <br /> ; PER 1104.11.1 <br /> I - I PROVIDE �� REINFORCEMENT <br /> BACKING SHALL BE <br /> I BACKING <br /> I PROVIDE <br /> J, <br /> FOR FUTURE // PROVIDED FOR <br /> i 4" MAX GRAB BARS FURTUFRE <br /> - FUTURE <br /> _ - \ r - - - , 0 12"MAX GRAB BARS cN <br /> r I \ I I I 0GRAB BARSINSTALLATION OF <br /> r o I - - I I I I I 24" MIN 24"MIN 24"MAX <br /> SHOWER <br /> I _ - 12" GRAB BAR AND ,IL / / / �//./AD// <br /> N • <br /> z I I I i Or/ 0���� ` / /�/// , ` ,���//�� COMPARTMENTS <br /> g I I PROVIDE %'/ PROVIDE MIN REINFORCING NOT <br /> I I I N I I BACKING •,r, z BACKING FOR REQUIRED IN TUBS WITH /////�//�/ <br /> 1 I i FOR GRAB $j0 g GRAB BARS PERMANENT TRANSFER , z z t diD, <br /> ' I L + \ L---i i BARS PER O A PER CODE SEATS 12 1/16" MAX z a I <br /> \ ////� <br /> I FORWARD /�� <br /> t T I I APPROACH CODE J�% %/ ///r%/ •��� 24" MIN 24 1116" MAX OrI I N c� °' co M <br /> iiiir d a :2 a <br /> a ry �' u w N <br /> J NOT ALLOWED �� io �i�0�////� i.A co <br /> OVEN AND rr-�� /ZZA 'i <br /> 4' 0" MIN RANGE co co _ xx� - # DATE DESCRIPTION <br /> 4'- 0" MIN / / I co - - Q 2 <br /> CLEAR FLOOR SPACE 2 ap Z SEAT WALL BACK WALL CONTROL WALL <br /> @ 2'-6"MIN <br /> M , M N \z FOR SEAT WALL UNITS <br /> CLEAR FLOOR SPACE CLEAR FLOOR SPACE @ REFRIGERATOR- / / co N <br /> @ REFRIGERATOR- OVEN & DISHWASHER PARALLEL AND FRONT BACKING NOT REQUIRED SHOWER STALL ELEVATIONS <br /> PARALLEL APPROACH APPROACH \� ir‘1, 0 <br /> PARALLEL APPROACH 5 31/32" 6 /32 ` <br /> 4' 0" MIN <br /> 30" MIN MAX AX 1, 36"MIN 1, DEVELOPMENT <br /> / <br /> CONTROL WALL BACK WALL OPPOSITE CONTROL WALL <br /> CLR 30 X 60 IN. TUB • 1830 BICKFORD AVE, <br /> i I INSULATE/PROTECT SUITE 201 <br /> i UNDERSIDE OF z z SNOHOMISH, WA 98290 <br /> ( COOKTOP TO g g 206.755.1290 <br /> \ - �- - ` _- 12 1/16" MA24"MIN 24 1/16" MAX 1 li <br /> IPREVENT BURNS 12�/16" MA24" MIN 24 1/16 MAX Zo To EDGE OF CLEAR <br /> AND 12 1/16" MAX T 1 FLOOR SPACE <br /> z I Z Z SHOCKS ( 11411 <br /> \ / g I 24"MIN 24 1/16"MAX 'T MUST ALIGN <br /> 1 1 - WITH CONTROL <br /> 1 I I O I MIN z z ~ 36" I I <br /> cs) <br /> I •I i ` N 8 a a Z MIN CLR ` WALL ALLOWED <br /> io - I - - _ - FLOOR SPACER Z I ONLY IN 30"X60" 1020 North Broadway <br /> I z I I v - z z2 ROLL IN <br /> 1 I ' 2 I I • z cN iN - cN iv - - MUST ALIGN I Everett,WA 98403 <br /> iN - 2 o o SHOWERS <br /> 1 I 2 a ,] • _�_ • ch I I WITH CONTROL co I I 608.2.2 <br /> i \ \ L FINISH WALL TO MATCH N & z I OR • WALL ` <br /> EXTEND FINISH FLOOR - ti_ F-`� Iz REMOVABLE 48"MIN 48"MIN ACCESSIBILITY DETAILS -TYPE <br /> EQ (ii <br /> _ EQ EQ �, EQ I N CABINET o z "B" UNIT <br /> 4'- 0" MIN 2'_6" I FINISHED PANEL z j - -T----+ -- 1--�----- CL " I 36 X 36 IN. INSIDE MINIMUM CLEAR 36 X 42 IN. INSIDE MINIMUM CLEAR <br /> ��J _L _ _ _ _ I I SHOWER STALL 1/2 IN. CURB MAX SHOWER STALL 1/2 IN. CURB MAX <br /> o / / .(1 cn <br /> PERMITTED PERMITTED I PERMITTED OPTION - 1 <br /> CLEAR FLOOR SPACE 1 @ CLEAR FLOOR SPACE 2 @ CABINETRY AT COOKTOP- L LAVATORY 48"MIN / LAVATORY LAVATORY <br /> COOKTOP- PARALLEL COOKTOP- FORWARD FORWARD APPROACH PER COMMON PER TYPE "B" AND/OR NOTE: DATE: Issue Date <br /> APPROACH APPROACH 60"MIN 1. ALL SHOWERS IN "OPTION -1" BATHROOMS SHALL MEET SHOWER CLEARANCE REQUIREMENTS <br /> SPACE UNIT LAV 60"MIN WATER 2. IF SHOWER IS ONLY BATHING FACILITY, SHOWER DIMENSIONS MUST BE 36"X 36" MIN. <br /> LAVATORY DRAWINGS 1' CLOSET 3. WALL BEHIND SHOWER SEAT SHALL NOT EXTEND BEYOND SHOWER COMPARTMENT. <br /> APPROACH 1 - PARALLEL DRAWINGS APPROACH 2- PARALLEL APPROACH 3 - FORWARD PROVIDE 90 DEGREE NAILING FLANGES AS REQUIRED. <br /> SHEET: <br /> O CLEARANCE @ TYPE B - KITCHEN © 3LEARANCES @TYPE B UNIT-TUB\SHOWER - CLEARANCES @ TYPE B - SHOWER AO <br /> ■ <br />