Laserfiche WebLink
p <br /> (2--- , . <br /> E509.2 ( R0 <br /> 1 <br /> LEGEND <br /> "SERVIT" POST CADWELD CONNECTION GROUND CONNECTOR <br /> I iii- -- <br /> TO COLUMN STEEL COLUMN BURNDY TYPE GC2929 -/ GROUND CONDUCTOR <br /> 11 <br /> __ LEAVE SLACK FOR TWO <br /> FUTURE COMPRESSION ii / (-3- 1 <br /> IIII MOTOR TERMINAL BOX TYPE CONNECTIONS 0 1" RGS CONDUIT STUB UP <br /> �/ E509-2 <br /> J <br /> #4/0 BARE COPPER - � 8"A.F.F NOTE 3 <br /> SHAKEPROOF EXTERNAL b 2 GENERAL NOTES ` <br /> TEETH LOCKWASHER, "'� FLOOR SLAB <br /> BURNDY"DURIUM" ® FLAT WASHER FINISHED FLOOR <br /> OR EQUAL ` a FLOOR SLAB TWO ROWS L(AS REQUIRED)COPPER 3/4 0 C.R SHALL HAVE <br /> -� NUT <br /> GROUND CONNECTOR <br /> GROUNDING DETAILS REFERENCE DRAWING E9 SERIES <br /> BURNDY TYPE GAR1529 DRAWINGS. <br /> DETAIL ,v ( <br /> RGS IS PREFERRED FOR GROUNDING CONDUCTOR. SLAB <br /> a ° SLEEVES&ABOVE GRADE EXTENSIONS. USE OF SCHED 40 <br /> ° , PVC IN LIEU OR RGS IS PERMITTED WHERE NOT SUBJECT TO <br /> MECHANICAL INJURY. <br /> GROUND CON UCTOR _ <br /> EXPLODED VIEW - GROUND CONNECTION (-1 --, BASEPLATE _ 7' 7 <br /> SCALE: NTS TYP / \ <br /> �� CONCRETE FOOTING <br /> CABLE TO CABLE CADWELD / GROUND CONDUCTOR <br /> I <br /> CONNECTION <br /> /.,/\ .. <br /> 4111-j CONSTRUCTION NOTES <br /> SECTION 2 GROUND CONDUCTOR THRU SLAB DETAIL (-3- <br /> SCALE: NTS TYP SCALE: NTS TYP <br /> MOTOR TERMINAL BOX #4/0 GND <br /> CONDUIT CONDUCTORS UP 5 1/4"T X 4"W X L(AS REQUIRED) <br /> TO SUBSTATION ROOM COPPER BAR BRAZED <br /> 0 GROUND BARS AND TRANSFORMERS ; TO COLUMN STIFFENER. <br /> O PHASE WIRES COUPLING FLEXIBLE COUPLING <br /> CONDUIT. SEE NOTE 2. BURNDY YGA •4 <br /> - TERMINAL(TYP.) <br /> I CONNECTOR �,6'. I MOTOR I <br /> GROUND WIRE �':• __._ �;�; <br /> ICI � MOTOR TERMINAL BOX � oi c� =� NOTE 1 % o �_ :_wc:cn,-: <br /> CONNECTOR o ' w w v FINISHED FLOOR <br /> _______------i w o <br /> GROUND WIRE CONNECTION DETAIL 4 NOTES e <br /> 1.BONDING JUMPER REQUIRED ON FLEXIBLE CONDUIT SIZES 1 1/2"AND <br /> SCALE: NTS TYP ABOVE. <br /> �'� 2. MINIMUM FLEXIBLE CONDUIT LENGTH 3'-0'°; MAXIMUM LENGTH 6'-0'°. I , <br /> TO#4/0 GROUND <br /> '71 / <br /> 3. USE LIQUIDTIGHT FLEXIBLE CONDUIT. (ijN GRID <br /> E500-1 #4/0 GROUND <br /> I i CONDUCTOR REFERENCE NOTES <br /> MOTOR CONNECTION DETAIL 5 1 I .4 <br /> SCALE: NTS TYP I <br /> SECTION (6 • <br /> SCALE: NTS TYP r-2- ) , <br /> CADWELD CONNECTION 0 9_ 4 0 E509-2 <br /> '"-. ,.....___- <br /> rC <br /> © .ryg0r,, <br /> 4 <br /> 1 '„ ,'�► I GROUND CONDUCTOR, <br /> BARE COD PER <br /> 114/0, 7 STRANDED its! ® 4 1 / <br /> GROUNDING CONDUCTOR «` " <br /> � e <br /> ‘ a0 <br /> � 1°' PVC CONDUIT STUB-UP <br /> Pj (I( re 1 <br /> 0 / 8��A.F.F. ` <br /> \ / <br /> t. FLOOR SLAB <br /> D <br /> 3/4" x10' LONGGROUNDROD LEGEND ------,„--- 0 <br /> 1- COPPER GROUND BAR, 1/4" X 4" X 18" OR AS SHOWN ON DRAWINGS. , <br /> 2- INSULATORS ISSUED FOR <br /> CONDUCTOR TO GROUND ROD 3- 5/8 LOCKWASHERS <br /> CONNECTION SECTION <br /> 4- WHERE APPLICABLE: WALL MOUNTING BRACKET. PLACE 6' ON CENTER. CONSTRUCTION <br /> 5- 5/8-11 X 1" H.H.C.S. BOLTS <br /> j STRUCTURAL <br /> SCALE: NTS TYP 6- 4/0 BARE COPPER CONDUCTOR TO GROUNDING COUNTERPOISE <br /> �� OR BUILDING STEEL. CONNECT PER SPECIFICATIONS. GROUND CONDUCTOR, = difference <br /> #4/0 BARE CO PER tq ti is engineered. <br /> ERICO/CADWELD, SQUARE D OR PRE-APPROVED EQUAL / 4www.harrisgroup.com <br /> \I Barris p REVISION"C"ONLY <br /> PROJECT NO: 0012630.04 <br /> GROUND BAR DETAIL r-8-- DRAWN NH PROJ MGR RLT <br /> GROUND CONDUCTOR PVC THRU SLAB DETAIL 9 <br /> ENGINEER: MWD APPROVED: RLT <br /> SCALE: NONE i SCALE: NTS 1E9-07, 1E'-08 509-2 <br /> CHECKED: EOF DATE 07.09.19 <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE .�'DIBE1v ACCEPTABILITY RER 12/05/14 GROUNDING DETAILS W6036604 C 07109119 <br /> OF WA,s /?4. THIS DESIGN AND/OR CHECKED <br /> A 777X CWC NEW BUILDING RECORD WBS 2548317 JMG DFC 01103117 RFW 12105114 SHEET c <br /> R G'� ,� SPECIFICATION IS <br /> B 777X CWC NEW BUILDING RECORD WBS 2548317 JMG DFC 07105117 em ® ti' ti� x_' O D ENGINEER TITLE BSA STRINGER GANTRY r <br /> �0�,Mg rn i A APPROVED BY DEPT. DATE DHECKED 12105114 E509..2 c <br /> C BSA STRINGER GANTRY IFC W6036604 HG RLT 07/09/19 BUILDING 40-05 V <br /> JOB N0. COMP N0 c <br /> 51289 W� APPROVED o <br /> ��•�' �GISTER�' S� DWG No. <br /> 07/09/2019 �s`Sj�NAL � APPROVED ELECTRICAL MASTER EVERETT,WA 40-058-E509-2 <br />