My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-58 Plans 2022-11-09 (5)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-58 Plans 2022-11-09 (5)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 10:04:08 AM
Creation date
8/4/2021 1:03:49 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
B1907-031
Year
2019
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STEEL <br /> LEGEND <br /> COLUMN <br /> (REF) ANGLE CLIP;2"x2"x2"LNGx1/4"THK. DRILL AND TAP EQUIPMENT <br /> FRAME <br /> CONTINUOUS WELD TO (SEE TABLE FOR SIZE) <br /> EQUIPMENT. DURIUM HEX NUT,WITH <br /> DRILL&TAP CLIP PER TABLE. <br /> BURNDY SERVIT BRONZE <br /> SERVIT POST,SEE TABLE <br /> FOR POST WASHER <br /> CADWELD TYPE'"HDV" SIZE (SEE TABLE) <br /> SEE TABLE BELOW BONDING BUSHING BONDING BUSHING <br /> COLUMN FOOTING ONE HOLE CLAMP, STEEL CITY <br /> FFINISHEDLOOR(REF) = EQUIPMENT FRAME GENERAL NOTES <br /> 1"RGS CONDUIT SLEEVE. EQUIPMENT #HS 103 ANCHOR TO ..L- GROUNDING DETAILS REFERENCE DRAWING SERIES E9. <br /> FINISHED FLOOR(REF) SEE (REF) CONCRETE <br /> BONDING BUSHING DETAIL USING"HILTI"#PSA 1/4"X1". <br /> 3,SHEET 509-2. <br /> /-- <br /> FINISHED FLOOR(REF) CONCRETE FOOTING <br /> \ --\- \\ r--- C <br /> 1"RGS CONDUIT SLEEVE - <br /> REFER TO DETAIL 3, - <br /> SHEET E509-2. \ 1 <br /> ti ONE HOLE CLAMP,"STEEL CITY" ONE HOLE CLAMP,"STEEL CITY" <br /> #HS-103;ANCHOR TO <br /> (SEE CONDUIT SLEEVE #HS 103 ANCHOR TO <br /> CONCRETE CONCRETE CONCRETE <br /> WITH"HILTI"#PSA 1/4"x1" FOUNDATION Ai GROUND WIRE SEE DETAIL 3, „ „ <br /> GROUNDING CONDUCTOR (REF) GROUND CABLE PLAN SHEET E509 2. <br /> USING HILTI #PSA 1/4 x1 . <br /> (SEE PLAN DRAWING) <br /> ALL NUMBERS IN TABLE ARE"BURNDY" DRAWING) I <br /> ALL NUMBERS IN TABLE ARE"BURNDY" ALL NUMBERS IN TABLE ARE"BURNDY" <br /> CABLE SERVIT HOLE TAP HEX SILICON <br /> CABLE CADWELD WELD SEALER SIZE POST THRU HOLE DURIUM BRONZE CABLE SERVIT HOLE TAP HEX SILICON <br /> SIZE METAL PACKING BUS BAR NUT LOCKWASHER SIZE POST THRU HOLE DURIUM BRONZE <br /> (21b.BAG) 5/8-11 BUS BAR NUT LOCKWASHER <br /> #4/0 KC28B1 17/32 5/8-11 <br /> #62C HEX BOX 5/8" 5/8-11 CONSTRUCTION NOTES <br /> #4/0 HDVBC-2Q 250 T 403 #4/0 KC28B1 17%32 5/811 5/8" <br /> 1/2-13 #62C HEX BOX <br /> #2/0 HDVBC-2G 200 T 403 #2/0 KC25B1 27/64 1/2-13 #50C HEX BOX 1/2 1/2-13 <br /> #2 HDVBC 1V 115 T 403 3/816 #2/0 KC25B1 27/64 1/2-13 1/2" <br /> : 06HEX <br /> 5C BOX <br /> #2 KC22B1 5/16 3/816 <br /> #38C HEX BOX 3/8 <br /> #2 KC22B1 I <br /> 5/16 3/8-16 3/8'° <br /> #38C HEX BOX <br /> • <br /> 1 <br /> , <br /> CADWELD TO BUILDING COLUMN (1) <br /> SCALE NTS EQUIPMENT GROUND OD <br /> EQUIPMENT FRAME GROUNDING DETAIL C3) <br /> /X \ <br /> ii ....." <br /> obQ , <br /> klr-l* STEEL <br /> COLUMN <br /> (REF) <br /> I <br /> BUILDING <br /> COLUMN <br /> I <br /> REFERENCE DRAWINGS <br /> CADWELD TYPE"HDV" <br /> ' SEE TABLE BELOW <br /> COLUMN FOOTING i <br /> 1"PVC CONDUIT SLEEVE <br /> 4 . _ <br /> - FINISHED FLOOR(REF) <br /> SLAB BAR IC_ <br /> _ <br /> _ \ <br /> IVONE HOLE CLAMP,"STEEL CITY" <br /> #HS-103;ANCHOR TO <br /> CONCRETE <br /> WITH"HILTI"#PSA 1/4"x1" <br /> GROUNDING CONDUCTOR <br /> ARMOR ALL NUMBERS IN TABLE ARE"BURNDY" <br /> EDGE CABLE CADWELD WELD SEALER <br /> i SIZE METAL PACKING <br /> (2Ib.BAG) <br /> #4/0 HDVBC-2Q 250 T-403 <br /> , <br /> . 11 1(,.____---1,k0-1- 1 I mr---r-i(________4>.< , 1 <br /> ISSUED FOR <br /> CONSTRUCTION <br /> STRUCTURAL <br /> ,,...1:: Our difference <br /> I is engineered. <br /> ARMORED EDGE GROUND 4 CADWELD TO GANTRY COLUMN 51 4,41. <br /> SCALE: NTS SCALE: NTS www.harrisgroup.com <br /> 07, 1E9 08 f E509 3 REVISION "C"ONLY <br /> - — _ PROJECT NO: 0012630.04 <br /> 1 <br /> DRAWN: NH PROJ MGR: RLT <br /> ENGINEER: MWD APPROVED: RLT <br /> ' CHECKED: EOF DATE: 07.09.19 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE .- ACCEPTABILITY DRAWN DATE SUBTITLE <br /> IBE RER 12I05114 CURRENT REVISION SYMBOL DATE <br /> A 777XCWCNEWBUILDING RECORD WBS2548317 JMG DEC 01/03/17 #�,�a wAsz,,r�.,4 } THIS DESIGN AND/OR CHECKED GROUNDING DETAILS W6036604 C 07.09.19 ` <br /> �+ S G> SPECIFICATION IS APPROVED RFW 12105114 SHEET <br /> B 777X CWC NEW BUILDING RECORD WBS 2548317 JMG DFC Oli05117 er ,-> ® g ;,, F_ o O " ENGINEER TITLE rz <br /> ENGIN 1` <br /> KVf+ rn x APPROVED BY DEPT. DATE DFC 12/05/14 BSA STRINGER GANTRY r <br /> . . . <br /> C BSA STRINGER GANTRY-IFC W6036604 HG RLT 07,09.19il /b. f , / fs n; , CHECKED E509.3 <br /> �� 51289 BUILDING 40-Q58 <br /> JOB N0. COMP N0. <br /> cw� ' APPROVED <br /> - ��'4,S�GISTEg�'c{�" I Q <br /> 07/09/2(19 , sIONAL APPROVED ELECTRICAL MASTER EVERETT,WA DWG No. 40-058-E509-3 ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.