My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2018 BLDG 40-58 Plans 2023-04-19
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-58 Plans 2023-04-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2023 2:32:39 PM
Creation date
8/4/2021 1:44:23 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
M1808-105
Year
2018
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAKEUP AIR UNIT SCHEDULE <br /> DESIGN CONDITIONS ELECTRICAL DATA BASIS OF DESIGN AUTOCLAVE <br /> AIR VOLUME OUTPUT UNIT WEIGHT INSTALL <br /> MARK CFM ESP (IN. WG) TSP (IN. WG) DB(F) WB (F) WINTER DB (F) MOTOR RPM BHP MOTOR HP HEATING TYPE GAS TYPE INPUT (MBH) (MBH) LAT (F) TEMP RISE (F) VOLTS/PH MCA MOP MANUFACTURER MODEL (LBS) PHASE <br /> MAU-01 36,000 0.25 1.55 85 70 21 1725 26.9 30 DIRECT GAS NATURAL 2,282.1 2,099.5 75 54 460/3 50.9 90 GREENHECK DGX-133-H42 4,582 AUTOCLAVE 1 <br /> MAU-02 36,000 0.25 1.55 85 70 21 1725 26.9 30 DIRECT GAS NATURAL 2,282.1 2,099.5 75 54 460/3 50.9 90 GREENHECK DGX-133-H42 4,582 AUTOCLAVE 1 <br /> - MAU-03 36,000 0.25 1.55 85 70 21 1725 26.9 30 DIRECT GAS NATURAL 2,282.1 2,099.5 75 54 460/3 50.9 90 GREENHECK DGX-133-H42 4,582 AUTOCLAVE 2 <br /> NOTES: <br /> 1. REFER TO SPECIFICATION SECTION 23 73 39 -OUTDOOR, DIRECT-FIRED HEATING AND VENTILATING UNITS. <br /> 2. COORDINATE FAN MOTOR WITH VFD (FURNISHED AND INSTALLED BY DIV 23, WIRED BY DIV 26). <br /> 3. H-O-A DISCONNECT PROVIDED BY DIV 26. <br /> 4. HORIZONTAL UNIT CONFIGURATION WITH BOTTOM DISCHARGE SHALL CONSIST OF AN INTAKE SECTION, AN ANGLED FILTER SECTION WITH MERV 13 FILTERS, A GAS-FIRED HEATING COIL SECTION, AND A FAN SECTION. GENERAL NOTES <br /> 5. EMCS CONTRACTOR SHALL PROVIDE CONTROL POINTS PER CONTROL DIAGRAMS. <br /> 6. PROVIDE WITH MANUFACTURED INSULATED ROOF CURB. <br /> 7. PROVIDE WITH EXTERNAL DDC TEMPERATURE CONTROL(2-10 VDC). <br /> 1. EQUIPMENT, PIPING, ETC. THAT IS GREYED OUT IS <br /> EITHER EXISTING OR TO BE INSTALLED WITH <br /> SUBSEQUENT AUTOCLAVES AT A LATER DATE. <br /> REFER TO AUTOCLAVE SUBSYSTEM SCHEDULES <br /> FOR INDICATION OF INSTALLATION PHASE. <br /> CITY OF EVERETT <br /> REVIEWED FOR PERMIT <br /> ZN <br /> '''\) F ` Asitii.0 . <br /> :;;.,:r3 cs,37 At i-<;ii..ii,. <br /> „._,il:' <br /> www.brph.cam Copyright r.2018 " , <br /> Architects Engineers,Stoie� Inc. ' . po,����crSTg�°�.�'>:'' <br /> 18020 33a/Ave W.Sub 531t Ceram*at At etz SIONA L V C . <br /> Lyrotcod, 96036 Arddlltlwe No.6032X5 t? <br /> 42 t1-3300 Enginasritg No.3137 <br /> Q <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL 'DATE' <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE (7----0; wash N ACCEPTABILITY JXK 06/12/18 SCHEDULES W2548317 0 06/12/18 <br /> 0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 r �T THIS DESIGN AND/OR CHECKEDc SPECIFICATION IS APPROVED JEW O6/12I18 SHEETENGINEERSIINCS APPROVED BY DEPT. DATE JLC INFER 06/12/18 TITLE Boeing777X CWC BUILDING�0A,�4g® RPH CHITM2 c-a <br /> 5 <br /> �P., a APPROVED BUILDING 40-58 JOB NO COMP NO. Y <br /> tiP,` 40-58-M2c-a <br /> ire of nuSN°�` APPROVED MECHANICAL MASTER EVERETT, WA DWG No. 40-58-M2c-a <br />
The URL can be used to link to this page
Your browser does not support the video tag.