Laserfiche WebLink
FAN SCHEDULE <br /> UNIT UNIT DRIVE ESP SOUND MOTOR WEIGHT <br /> NO LOCATION SERVICE FAN TYPE TYPE CFM IN WG FAN <br /> RPM BHP LBS BASIS OF DESIGN NOTES <br /> RPM HP VOLTS/PH <br /> EF-01 1-D.25/1.0 RESTROOMS/JAN CLOSET INLINE BELT 2,900 0.7 26 1636 1.11 1725 1-1/2 460/3 250 COOK / 150SQ1A 1, 2, 4, 7, 8 <br /> EF-02 1-E/1.0 SUBSTATION INLINE BELT 8.000 1.5 16.6 1087 3.8 1725 5 460/3 660 GREENHECK / BSQ-240-50 1, 2, 4, 5, 7, 8 <br /> EF-03 1-G.25/1.0 RESTROOMS/JAN CLOSET INLINE BELT 2,900 0.7 26 1636 1.11 1725 1-1/2 460/3 250 COOK / 150SQ1A 1, 2, 4, 7, 8 <br /> EF-04 1-H.75/1.0 SUBSTATION INLINE BELT 8,000 1.5 16.6 1087 3.8 1725 5 460/3 660 GREENHECK /BSQ-240-50 1, 2, 4, 5, 7, 8 <br /> EF-05 1-B/4.0 SUBSTATION INLINE BELT 16,000 1.5 24 596 7.6 1725 10 460/3 1020 GREENHECK / BSQ-420-75 1, 2, 4, 5, 7, 8 <br /> EF-06 1-B.25/4.0 RESTROOMS/JAN CLOSET INLINE BELT 2,400 0.5 22 1941 0.94 1725 1 460/3 200 COOK / 135SQ1B 1, 2, 4, 7, 8 <br /> EF-07 1-G.25/4.0 RESTROOMS/JAN CLOSET INLINE BELT 2,400 0.5 22 1941 Q.94 1725 1 460/3 200 COOK / 135SQ1B 1, 2, 4, 7, 8 <br /> EF-08 1-J.75/4.0 SUBSTATION INLINE BELT 16,000 1.5 24 596 7.6 1725 10 460/3 1020 GREENHECK / BSQ-420-75 1, 2, 4, 5, 7, 8 <br /> SF-17 1-H.5/1.0 BOILER ROOM INLINE BELT 4,920 0.30 333 0.5 1725 1-1/2 460/3 537 GREENHECK / BSQ-300 1, 2, 4, 5, 7, 8 <br /> EF-10 CW-A/2.7 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-11 CW-B.75/3.0 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-12 CW-D.25/3.0 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-13 CW-D.75/3.0 SUBSTATION INLINE BELT 8,000 1.5 16.6 1087 3.8 1725 5 460/3 660 GREENHECK / BSQ-240-50 1, 2, 4, 5, 7, 8 <br /> EF-14 CW-D.75/3.0 SUBSTATION INLINE BELT 16,000 1.5 24 596 7.6 1725 10 460/3 1020 GREENHECK / BSQ-420-75 1, 2, 4, 5, 7, 8 <br /> EF-15 CW-D.75/3.0 RESTROOM/JAN CLOSET INLINE BELT 3,900 0.6 9.2 555 0.70 1725 3/4 460/3 590 GREENHECK /BSQ-240-7 1, 2, 4, 7, 8 <br /> EF-16 CW-E.5/3.0 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-17 CW-A.5/3.0 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-18 CW-F.75/3.0 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-19 CW-C.5/3.0 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-20 CW-G.5/2.0 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-21 CW-H.5/2.0 SUBSTATION INLINE BELT 8,000 1.5 16.6 1087 3.8 1725 5 460/3 660 GREENHECK /BSQ-240-50 1, 2, 4, 5, 7, 8 <br /> EF-22 CW-J/3.0 SUBSTATION INLINE BELT 16,000 1.5 24 596 7.6 1725 10 460/3 1020 GREENHECK / BSQ-420-75 1, 2, 4, 5, 7, 8 <br /> EF-23 CW-J/3.0 RESTROOM/JAN CLOSET INLINE BELT 2,840 0.5 9.1 586 0.61 1725 3/4 460/3 590 GREENHECK /BSQ-240-7 1, 2, 4, 7, 8 <br /> EF-24 CW-J.75/3.0 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-25 CW-H.5/3.0 RELIEF MIXED FLOW INLINE DIRECT 60,000 2.0 92 LWA INLET 690 37.1 1725 60 460/3 4400 COOK /540QMXDO6 1, 2, 5, 8, 11 <br /> 96 LWA OUTLET <br /> EF-26 1-A/1.0 TUNNEL EXHAUST FAN WALL BELT 6,000 0.5 14.1 762 1.36 1725 2 460/3 250 COOK /245-ACWB 1, 2, 4, 5, 6 <br /> EF-27 1-E/3.65 AUTOCLAVE CONTROL RM INLINE BELT 250 0.5 NOT USED 1401 .06 1725 1/4 115/1 79 GREENHECK /BCF-106-4 3, 8 <br /> EF-28 3-B.5/2.70 RESTROOM CEILING DIRECT 150 0.5 3.5 1050 - 1725 150W 115/1 10 GREENHECK /SP-B150 2, 3, 8 <br /> EF-29 NOT USED <br /> EF-30 1-D.75/1.0 TUNNEL EXHAUST FAN INLINE BELT 6,000 1.0 16.0 827 1.75 1725 3 460/3 480 COOK /245SQIB 1, 2, 4, 5, 6, 7, 8 <br /> SF-16 1-H.25/1.0 VACUUM RM INLINE BELT 11,900 0.5 422 2.3 1725 5 460/3 850 COOK /365SQIB 1, 2, 4, 5, 6, 7, 8 <br /> EF-32 1-L/1.OA TUNNEL EXHAUST FAN WALL BELT 6,000 0.5 14.1 762 1.36 1725 2 460/3 250 COOK /245-ACWB 1, 2, 4, 5, 6 <br /> EF-33 1-C.5/4.0 INDUSTRIAL WASTE RM INLINE BELT 23,100 1.0 30 662 10.5 1725 15 460/3 1020 GREENHECK /BSQ-420-100 1, 2, 4, 5, 7, 8 <br /> EF-34 1-C.25/4.0 VACUUM RM INLINE BELT 11,250 1.5 23 659 5.36 1725 7.5 460/3 660 GREENHECK /BSQ-360-30 1, 2, 4, 5, 7, 8 <br /> EF-35 1-E.25/1.0 VACUUM RM INLINE BELT 22,040 1.3 34 671 11.11 1725 15 460/3 1120 GREENHECK/ BSQ-420-150 1, 2, 4, 5, 7, 8 <br /> EF-36 1-E.25/0.10 VACUUM RM INLINE BELT 2,760 .25 16.2 1117 0.56 1725 3/4 120/1 320 COOK/ 165SQIB 1, 2, 4, 5, 7, 8 <br /> EF-37 1-F/1.0 SIDEWALL DIRECT 3,335 .25 11.3 1361 0.35 1725 3/4 120/1 40 GREENHECK /SE1-18-429 2, 4, 5 <br /> TF-01 1-G.75/1.0 TUNNEL EXHAUST FAN INLINE BELT 16,800 1.75 574 9.0 1725 10 460/3 1020 GREENHECK / BSQ-420-75 1, 2, 4, 5, 7, 8 GENERAL NOTES <br /> EF-39 1-H.25/4.0 VACUUM RM INLINE BELT 20,000 1.5 30 671 10.5 1725 15 460/3 1020 GREENHECK /BSQ-420-100 1, 2, 4, 5, 7, 8 <br /> EF-40 1-H.514.0 INLINE BELT 9,400 1.5 22 799 4.44 1725 7.5 460/3 525 GREENHECK / BSQ-300 1, 2, 4, 5, 7, 8 1. EQUIPMENT, PIPING, ETC. THAT IS GREYED OUT IS <br /> EF-41 1-F.25/4.0 ELEC ROOM SIDEWALL DIRECT 1,760 .25 7.8 1060 0.16 1725 3/4 120/1 40 GREENHECK /SE1-18-424 2, 4, 5, 12 EITHER EXISTING OR TO BE INSTALLED WITH <br /> SUBSEQUENT AUTOCLAVES AT A LATER DATE. <br /> EF-42 1-F/1.0 ELEC ROOM SIDEWALL DIRECT 1,760 .25 7.8 1060 0.16 1725 3/4 120/1 40 GREENHECK I SE1-18-424 2, 4, 5, 12 REFER TO AUTOCLAVE SUBSYSTEM SCHEDULES <br /> EF-43 RFM-E.85/4.1 AUTOCLAVE UPBLAST CENTRIF. BELT 18,000 0.5 21 526 4.32 1725 5 460/3 440 COOK /402ACRUB 1, 2, 5, 6, 8, 10, 13 FOR INDICATION OF INSTALLATION PHASE. <br /> EF-44 RFM-E.6/4.1 AUTOCLAVE UPBLAST CENTRIF. BELT 18,000 0.5 21 526 4.32 1725 5 460/3 440 COOK /402ACRUB 1, 2, 5, 6, 8, 10, 13 <br /> EF-45 RFM-E/4.1 AUTOCLAVE UPBLAST CENTRIF. BELT 18,000 0.5 21 526 4.32 1725 5 460/3 440 COOK /402ACRUB 1, 2, 5, 6, 8, 10, 13 <br /> EF-46 RFM-D.75/4.1 AUTOCLAVE UPBLAST CENTRIF. BELT 18,000 0.5 21 526 4.32 1725 5 460/3 440 COOK /402ACRUB 1, 2, 5, 6, 8, 10, 14 <br /> EF-47 RFM-D.25/4.1 AUTOCLAVE UPBLAST CENTRIF. BELT 18,000 0.5 21 526 4.32 1725 5 460/3 440 COOK /402ACRUB 1, 2, 5, 6, 8, 10, 14 <br /> EF-48 RFM-C.85/4.1 AUTOCLAVE UPBLAST CENTRIF. BELT 18,000 0.5 21 526 4.32 1725 5 460/3 440 COOK /402ACRUB 1, 2, 5, 6, 8, 10, 15 <br /> SF-01 CW-D.5/2.OA SUBSTATION INLINE BELT 8,000 1.5 16.6 1087 3.8 1725 5 460/3 450 GREENHECK / BSQ-240-50 1, 2, 4, 5, 7, 8, 9 <br /> SF-02 CW-D.5/2.OB SUBSTATION INLINE BELT 16,000 1.5 20 596 7.6 1725 10 460/3 832 GREENHECK /BSQ-420-100 1, 2, 4, 5, 7, 8, 9 <br /> SF-03 CW-H.5/2.0A SUBSTATION INLINE BELT 16,000 1.5 20 596 7.6 1725 10 460/3 832 GREENHECK /BSQ-420-100 1, 2, 4, 5, 7, 8, 9 <br /> SF-04 CW-H.5/2.0B SUBSTATION INLINE BELT 8,000 1.5 26.6 1087 3.8 1725 5 460/3 450 GREENHECK / BSQ-240-50 1, 2, 4, 5, 7, 8, 9 <br /> SF-05 CW-H/2.30 TUNNEL SUPPLY FAN MIXED FLOW INLINE BELT 23,600 2.0 80 LWA INLET 687 11 1725 15 460/3 2220 COOK /402QMX 1, 2, 4, 5, 6, 7, 8, 9, 10 <br /> 84 LWA OUTLET _ <br /> SF-06 1-B.6/4.4 TUNNEL SUPPLY FAN MIXED FLOW INLINE BELT 23,600 1.75 80 LWA INLET 660 9.6 1725 10 460/3 2220 COOK /402QMX 1, 2, 4, 5, 6, 7, 8, 9, 10, 17 <br /> tl_5 LWA OUTLET _ <br /> • SF-07 1-G.75/4.4 TUNNEL SUPPLY FAN MIXED FLOW INLINE BELT 23,600 1.5 80 LWA INLET 633 8.3 1725 10 460/3 2220 COOK /402QMX 1, 2, 4, 5, 6, 7, 8, 9, 10 <br /> 84 LWA OUTLET <br /> SF-08 CW-A.25/2.0 STAIR VENTILATION INLINE DIRECT 3,300 1.0 24 1725 1.14 1725 2 460/3 160 GREENHECK /SQ-160-VG 1, 5, 6, 8, 16 <br /> SF-09 CW-C.5/2.0 STAIR VENTILATION INLINE DIRECT 4,400 1.0 24 1725 1.8 1725 2 460/3 160 GREENHECK /SQ-160-VG 1, 5, 6, 8, 16 <br /> SF-10 CW-E/2.7 STAIR VENTILATION INLINE DIRECT 2,200 1.0 14.9 1555 0.75 1725 1 460/3 104 GREENHECK /SQ-140-VG 1, 5, 6, 8, 16 <br /> SF-14 CW-H.25/2.3 STAIR VENTILATION INLINE DIRECT 2,750 1.0 14.5 1315 0.86 1725 1 460/3 160 GREENHECK /SQ-160-VG 1, 5, 6, 8, 16 <br /> SF-15 CW-L/2.3 STAIR VENTILATION INLINE DIRECT 3,300 1.0 24 1725 1.14 1725 2 460/3 160 GREENHECK /SQ-160-VG 1, 5, 6, 8, 16 <br /> NOTES: <br /> 1. VFD PROVIDED BY DIVISION 26. <br /> 2. CONTROLLED FROM BUILDING MANAGEMENT SYSTEM PROVIDED UNDER DIVISION 23. <br /> 3. DIVISION 23 SHALL FURNISH AND MOUNT STARTER/H-O-A DISCONNECT. DIVISION 26 SHALL WIRE <br /> STARTER/DISCONNECT. <br /> 4. PROVIDE OSHA GUARD. <br /> 5. PROVIDE PREMIUM EFFICIENCY MOTOR. <br /> 6. PROVIDE BACKDRAFT DAMPER. <br /> 7. PROVIDE SIDE MOUNTED MOTOR. <br /> 8. PROVIDE VIBRATION ISOLATORS. <br /> 9. PROVIDE FILTER BOX. <br /> 10. PROVIDE ALUMINUM WHEEL. <br /> 11. PROVIDE PIEZOMETER AIRFLOW MONITORING RING AND INLET TAP FOR SUPPLY FAN. EXTEND SENSOR <br /> TUBES TO EXTERIOR OF UNIT CASING. TERMINATE WITH BRASS BARBS. <br /> - <br /> 12. PROVIDE LINE VOLTAGE THERMOSTAT. ;.. - N-Ga ,- ,aa, <br /> 13. TO BE INSTALLED WITH FIRST AUTOCLAVE. • -,,I Co':ik:,: <br /> 14. TO BE INSTALLED WITH SECOND AUTOCLAVE. T 0�' W9sii.- <br /> 15. TO BE INSTALLED WITH THIRD AUTOCLAVE. � -4, � t;,� <br /> 16. CONTROLLED BY FIRE ALARM SYSTEM. :;;!. .;-,7. <br /> .:; f I' ,;` <br /> 17. VERTICAL MOUNT. ' <br /> www.brph,corn Copyright 0 '18 <br /> Architects Engineers, Inc, " `;:%lp,, 4 1476 vs) s. <br /> 19020 33ndAye W,Sute 530 * a labia iSSIONA L V, <br /> Lyrrmood,Votati4c$1,96036 Wisdom I+k,. .,12 Q <br /> Enphearing NC,3t31 <br /> c <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE (7-..-c.; wgsH ACCEPTABILITY JXK 06/12/18 SCHEDULES W2548317, 0 06/12/18717. <br /> 0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 (4.. /' - ''soTSDESIGNAND/OR JEWKED 06/12/18 SHEET <br /> SPECIFICATION IS APPROVED co <br /> g)i_49ZIPEfilleie <br /> BRPHNEERSECTS ENGINEER TITLE Boeing 777X CWC BUILDING N <br /> ENGINEERS INC. APPROVED BY DEPT. DATE JLC 06/12/18 I\i12e-a <br /> No.3137 CHECKED <br /> � BUILDING 40-58 <br /> iii <br /> �/\ - �. APPROVED <br /> P JOB N0. COMP NO. 40-58-M2e-a <br /> C,gre �F AUTNO��� APPROVED MECHANICAL MASTER EVERETT, WA DWG NO. 40-58-M2e-a <br />