3003 W CASINO RD 2018 BLDG 40-58 Plans 2023-04-19
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-58 Plans 2023-04-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/19/2023 2:32:39 PM
Creation date
8/4/2021 1:44:23 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
M1808-105
Year
2018
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1D.62 QD"56► (EDr 5) (4.00) <br /> _./ <br /> TERMINATE DISCHARGE WITH GOOSENECK <br /> AND INSECT SCREEN OVER OPENING,TYP. <br /> OF(4) 12"GN2 RELIEF VENTS. 1 > 3 \ Ili I LEGEND <br /> • <br /> SEE SHEETS 40-58-M1a-a,40-58-M1b-a,&40-58-M2a-a FOR KEY, <br /> . # <br /> 1 ruT <br /> LEGEND,AND GENERAL NOTES. <br /> { <br /> GENERAL NOTES <br /> I I <br /> 24"EXHAUST PIPE WITH 4" INSULATION TERMINATED 10'-0"ABOVE FACTORY • <br /> ROOF PARAPET. REFER TO SHEET M536a FOR INDUSTRIAL CAP DETAIL. <br /> I ' E. 4" EMISSIONS TESTING PORT WITH BLIND FLANGE,TYPICAL TWO PER STACK. , • <br /> _ THE PORTS ON EACH INDIVIDUAL STACK SHALL BE SEPARATED BY 90°. <br /> PROVIDE AT LEAST 2'-0"OF SPACE DIRECTLY IN FRONT OF EACH PORT. <br /> PROVIDE THE PORTS APPROXIMATELY 4'-0"ABOVE THE ROOF. INSTALL EYE <br /> BOLTS ABOVE EACH PORT ON THE EXHAUST PIPE APPROXIMATELY 4'-0" <br /> II--- ABOVE EACH PORT. EYE BOLTS SHALL EXTEND BEYOND INSULATION. <br /> a <br /> I I © 36"EXHAUST PIPE WITH 2" INSULATION TERMINATED 10'-0"ABOVE FACTORY <br /> 205'-51/16"-FACTORY ROOF PARAPET ROOF PARAPET. REFER TO SHEET M536a FOR INDUSTRIAL CAP DETAIL. <br /> 4 20"COOLING TOWER WATER RETURN HEADER. <br /> MANUAL ISOLATION VALVE, <br /> NW PS GNPSR 2 9 6 PNEUMATIC-OPERATED ISOLATION VALVE,TYP. <br /> I <br /> PS-GNPSR-3-9 I PS-CE-11 El. © 20"COOLING TOWER WATER SUPPLY HEADER. <br /> 1 <br /> 110100 PS-GNPSR-4-9 I PS CE 21 KW I I 8 > TERMINATE <br /> OPENINGAT DISCH10-0ARGEABOVE WITH <br /> BUMP GOOSENECKOUTROOF,AND <br /> TYP.INSEOF(4)CT1/2 SCREENGN2BLEED OVER <br /> _------H PS-GNPSR-1-9 <br /> PS-GN-7 II, VENTSSithb.. _ , . . <br /> _.,-----1 <br /> = v 9 6"VENT.TERMINATE DISCHARGE WITH GOOSENECK AND INSECT SCREEN <br /> u I OVER OPENING AT 10'-0"ABOVE BUMP OUT ROOF <br /> — - _ _ _ _-1I I i 10. EQUIPMENT, PIPING, ETC.THAT IS GREYED OUT IS EITHER EXISTING OR TO BE • <br /> I INSTALLED WITH SUBSEQUENT AUTOCLAVES AT A LATER DATE. REFER TO <br /> PS GNPSR 2 8 a1 AUTOCLAVE SUBSYSTEM SCHEDULES FOR INDICATION OF INSTALLATION <br /> M. I II <br /> lill PS GNPSR 3 8 f PS CE 10 IIIIW <br /> \ -\1 il i <br /> LW PROVIDE GUIDED SUPPORT FOR PIPING AT LOCATION INDICATED. <br /> lill PS GNPSR-4 8 �j-- PS CE 20 MINIMUM I ' /( / ® 4"VENT ISOLATION VALVE <br /> liliW PS-GNPSR-1-8SI --( -� / PS GN 6 10' 0 1/2" i <br /> ® PROVIDE HAND LEVER ON OUTLET ISOLATION VALVE FOR BALANCING <br /> I,,, ,.� ig , PURPOSES. <br /> 11110. �� i: <br /> Illi : <br /> �91��M • <br /> PS-GNPSR-2-7 I _ - M- .. ) ' <br /> • <br /> PS-GNPSR-3-7 — PS-CE-9 II _ _ - <br /> IOW EI <br /> PS-GNPSR-4-7 PS-CE-19 11 - - <br /> PS GNPSR 1 7 - PS GN 5 <br /> 1 . . CONSTRUCTION NOTES • <br /> i <br /> II II i i (I OPCT <br /> — _a� _ � � 850E <br /> II I I O <br /> I 11 ' ' Il � I I J t I. <br /> � i <br /> PS-GNPSR-2-6 I '� j � <br /> PS-GNPSR-3-6 PS CE 8 I - <br /> _ <br /> 111100. PS-GNPSR-4-6 ° - PS-CE-18 I <br /> F, <br /> OW PS GNPSR 1 6 I PS GN 4 IIW <br /> M. PS-GNPSR-2-5 a ia.-I - _ _ — . o I • <br /> • <br /> MEW PS-GNPSR-3-5 - I ` PS CE 7 I 112"CA-4"DRAIN <br /> 13 REFERENCE DRAWINGS <br /> PS-GNPSR-4-5 , �`� I - PS-CE-17 � ' �� 3, <br /> .: <br /> %11 .-.. - <br /> • <br /> 6 <br /> PS GN 3 <br /> KW PS-GNPSR-1-5 ; P. <br /> "DRAIN 1 10"CTWS 5 <br /> IIIEW 10"CTWR 4 <br /> h __. __,-,._ _„--- _ , <br /> - - - <br /> c= <br /> r i 8 > CF_ <br /> -4„.,.f,i 11_,...: <br /> 1 I 9 , LEVEL 3 <br /> A , <br /> 14 - <br /> • <br /> III <br /> I � } <br /> , i <br /> - j <br /> I - <br /> yap 16 <br /> Ijgij <br /> sr fi;. <br /> , <br /> I <br /> 1 PROCESS COOLING TOWER WEST SECTION z <br /> ^� . . . • <br /> _ — i — — SCALE: 1/4" = 1' 0" 1M160-34Jj539a <br /> —, - - ..- <br /> - —___— -___- — &- - — — = = . - --—= _ - —— - - <br /> _ <br /> —�a'+7�r�1 -- -• l•`M.'F"�'l=.l.';.,11.• &'!R"M _V _' m!=v_er.'L4_•S-'!3' ' r -�• IE :�'S"3--:..'�.'M 3.° �r—x� efr <br /> • <br /> I LNG C <br /> . <br /> • <br /> 2 I �� , 't: 1 0 2' 4' 8' 12' <br /> www,brph.tom Copyright 2018 �� - .ice" 1/4" = 1'-0" <br /> SECTION - GASES U P BUILDING 1 Architects Engineers, Inc. :.,p0� ��GISTER.� ,� <br /> SCALE: 1/4"= 1' 0" M539a ora l on 6'70IVAL 'V '` <br /> 425 045OO Aid>>fw�aa No.8/3236612 . ... ., .r . <br /> Emblem No.3137 'Em <br /> I jDRAWN DATE SUBTITLE 1CURRENT REVISION !SYMBOL DATE a. <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE r;;-- <br /> wAsy ACCEPTABILITY JXK 06/12/18 AUTOCLAVE PIPING SECTIONS W2548317 Q 06/12/18 vLo <br /> 0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 �r THIS DESIGN ANDIOR CHECKED I N SPECIFICATION IS APPROVEDJEW 06112118 SHEET�0�AOW® RPHARCHI ARCHITECTS <br /> APPROVED BY DEPT. DATE JLC INEER 06/12/18 TITLE Boeing 777X CWC BUILDING co <br /> NO.3137 CHECKED f5 3 9 a co <br /> � o APPROVED <br /> BUILDING 40-58 <br /> �06 No. COMP No. 40-58-M539a <br /> F°gT4- OF AUTWO�`P� APPROVED MECHANICAL MASTER EVERETT,WA DWG NO. 40-58-M539a <br />