Laserfiche WebLink
1 <br /> ® PS-GNPSR-2-4 r <br /> 111> PS-GNPSR-3-4 PS-CE-6 ® LEGEND <br /> PS-GNPSR-4-4 PS-CE-16 III, , SEE SHEETS 40-58-M1a-a,40-58-M1b-a, &40-58-M2a-a <br /> OWFOR KEY, LEGEND,AND GENERAL NOTES. '' <br /> ® PS GNPSR 1 4 PS GN 2 ® X INDICATES GUIDED LINE STOP(X,Y,Z)FOR PIPING. <br /> • Foisil INDICATES GUIDED SUPPORT FOR PIPING((X,Z)OR(Y,Z)). <br /> _ ._': ; ° --_ _; _•. ��----------- _--__.-. .__. __. __ l • , I - j_; I :----.__._.__ INDICATES VERTICAL SUPPORT Z FOR PIPING. <br /> I • - — 201,C <br /> ° <br /> mo <br /> I <br /> yy e� <br /> t3 � I� III � I +A"' TW <br /> . . t� _ — PS-CTWR-4 <br /> .. .. _� COORDINATES: <br /> „ .. PS-CTWS-5 a - <br /> -` PS-CTWR-1 X=NORTH-SOUTH <br /> g''� ._ a I. .., PS-CTWS-4 i <br /> 1 Y EAST WEST <br /> ��.�..:-. _ Z VERTICAL <br /> 1 — � �-� 6 COLLECTION PIPE VENT <br /> , <br /> _ �_ _ - - �a ' PS-CTWS-6 <br /> _.. .__. ...._ y I ,---�� J I �-- --10 CTWS .. <br /> 2 <br /> 20"CTWS 1112" 24"GASEXHAUSTPIPEW/4INSUON 36GN2EXHAUSTPIPEW/2 INSUON 4"VENTOTES <br /> ilw NSULATE EXPANSION JNT PER VENDOR'S RQUIREMENTS • <br /> ® :: :EEF <br /> ® IP J a <br /> 1/2"GN2 BLEED,TYP.4 -2"PW 20"CTWR REFER TO ELECTRICAL DRAWINGS FOR HEAT TRACE � <br /> REQUIREMENTS.. <br /> ® PS GNPSR 4 3 __ Ls <br /> �� :::: <br /> ® 2MCCWSTOPOCS(DDDEEE).PS GNPSR 1 3 26"GAS II -15 ® II 1l2 PS CTWS 1 4 3B6"CONNECTION TO NITROGEN SILENCER EXHAUST STACK, POC <br /> ®� !� II 3/4" CA DROP TO DUPLEX OUTLET,4'6"A.P.F.. SEE DETAIL ON <br /> 3 • SHEET M536a. <br /> \ 0 1 PS-CTWS-2 <br /> 1 j� <br /> PS-CTWS-3 6. EQUIPMENT,PIPING, ETC.THAT IS GREYED OUT IS EITHER <br /> _ - _ _ I c .. <br /> ' \ \ • . . . . <br /> :011111100 <br /> +� EXISTING OR TO BE INSTALLED WITH SUBSEQUENT AUTOCLAVES <br /> - .11 I 10"CTWSAT A LATER DATE. REFER TO AUTOCLAVE SUBSYSTEM SCHEDULESFOR INDICATION OF INSTALLATION PHASE. <br /> ' „ ] i <br /> fir, © uS h& 4 <br /> i I I 3"MCCWS ' '' <br /> _ y• ICI<.� 8"GN2 SAFETY RELIEF VALVE CONNECTION POC(G, H, I,J). <br /> 011kCA t <br /> YI I 0 — _ 8 3" EMERGENCY SOLENOID VALVE FROM PROCESS WATER TIED <br /> (2) 1 1/2"GAS VENTS (2) 1/2"GAS VENT I I <br /> II �' PS-CTWR-3 INTO MCCWS. <br /> 14"GN2 rti��[ <br /> 3"PW � ----3/4"CA(2)3/4"GAS VENTS (2) 1/2 — <br /> GAS VENT I I i . <br /> 9. REFER TO ARCHITECTURAL DRAWINGS FOR PENETRATION AND <br /> it _ ;.:; A © �` SEALING REQUIREMENTS. <br /> 37 <br /> s� -- E.rJ ; 10. COOLING TOWERS NOT SHOWN FOR CLARITY. <br /> /I' \ \\ a II 'i `-� <br /> 11. REFER TO STRUCTURAL SHEET S560-26 FOR DETAILS OF <br /> � ;' -- I =-- ;4 __ _,�: - PS-GNPSR-2-2 14 4 <br /> - ___-_: 'f �\y Isi I AUTOCLAVE PIPE SUPPORTS. <br /> AUTOCLAVE II �� - .. -� <br /> VESSEL PS GNPSR 3 2 14 ; PROVIDE GUIDED LINE STOP FOR PIPING AT LOCATION INDICATED. <br /> PS GNPSR 4 2 14 n 1' ® PROVIDE GUIDED SUPPORT FOR PIPING AT LOCATION INDICATED. <br /> � � / NITROGEN SILENCER - ,, <br /> PS GNPSR 1 2 14 EXHAUST STACK(BY _ 14 PROVIDE VERTICAL SUPPORT FOR PIPING AT LOCATION <br /> -`' ,/ AUTOCLAVE VENDOR) . INDICATED. <br /> I s_ 1 <br /> I <br /> i • 111 CA <br /> MOTOR CAPSULE INSULATE GN2 RELIEF PIPING n <br /> (BY AUTOCLAVE <br /> FROM POC TO AUTOCLAVE UPII. • 1, <br /> ° VENDOR),TYP. - - - - TO 8'-0"ABOVE MOTOR II 1 <br /> I / _ CAPSULE PLATFORM I <br /> o <br /> �� � �1 III ,�,"CTWR I, I CONSTRUCTION NOTES <br /> c i III 1 II <br /> , I I f . 0 _ Ii 1 I PROVIDE HAND LEVER ON OUTLET ISOLATION VALVE FOR BALANCING <br /> - t I b - I. --HE S� PURPOSES <br /> �' �� �1 3`, a _ n 4"DRAIN <br /> I �f <br /> I <br /> fl fflI I - 1 ©- CONNECT 2" PW TO EXISTING 2" VALVE ON PW HEADER. i <br /> • <br /> �� II CONNECT 10" CTWS BRANCH TO EXISTING 10"VALVE ON CTWS HEADER. <br /> " o, r µ a 31k DRAIN <br /> ° 1 , r, x - -` _ I _ _ <br /> ` I <br /> s <br /> i k Il II','' - �>r,- --fir T-1. � �' 7 v(.� i�°p' ��xi i ',. i .� <br /> - _ A''(` ' �,.1,f3I ,,,: -_- 1 - „ II it <br /> 1l ..._.-: ___ __ _.- - __,_�I _ ,: t ;,,_ K I CONNECT 20 CTWR TO EXISTING 20 VALVE ON CTWR HEADER. <br /> ! � - 4 20 CTWR <br /> 1 k _. i-i i , F 1 —_ -,....ak. • <br /> r - <br /> _"-- _ �, , s��,=. � �, :�, \, ;;; :\ , �; �.. � I , ,� f, ,��;: ! _ INSTALL FISHER ACTUATOR TO EXISTING 10" BELIMO BFV. REFER TO <br /> I � � 2"PW <br /> ;. \ ( ' - 33 I BOM ON P&ID SHEET M332a-a FOR DETAILS. <br /> ; <br /> ; 11/2CA <br /> I <br /> 11; _ <br /> i <br /> f f JJ <br /> w i , g 9 1 I �� ___� — J . <br /> .r. I 311 MCCWS V� � 'Ia� =11 11 1 = 3/4"CA , 1 ;,1 �;I I REFERENCE DRAWINGS <br /> PURGE FAN a ( - ; , 14� I.1 ti_.� 411, I: <br /> (BY AUTOCLAVE I j '�..i ( I I k I <br /> VENDOR) I - E' Oti .. <br /> I i i ifil I <br /> o-1 <br /> I <br /> ; <br /> .1: ,i, . (J�j\ <br /> qg <br /> , <br /> N <br /> \ , <br /> 1 tt <br /> 1 I <br /> 40 . <br /> '45 <br /> a t GNCI <br /> i <br /> '-----1,___!..:11. iI' <br /> , . - <br /> I ' 1 ,1 I ' II - li'' I F <br /> ;I, , <br /> i_ II 1 ' .t - <br /> II <br /> • <br /> © REFER TO DETAIL /1`'• , <br /> ON M538a 4.80 • 5.00 <br /> Z <br /> TYP.x 4 <br /> REAR AUTOCLA <br /> VE #2 SECTION COOLING TOWER PIPING SUPPORT DETAIL 2 <br /> SCALE: 1/4"= 1'-0" 1M160-29a M540a SCALE: 1/8"= 1'-0" RFM160-34a M540a <br /> • <br /> 0 2' 4' 8' 12' <br /> 1 —1111 B R PH __ <br /> ..,::, <br /> .... „ , <br /> FA <br /> s ::......,,, O l .:a <br /> . ,. <br /> • <br /> „,,,,,.,:;.„:: <br /> ::::::,, ....., s..., <br /> .....„,;:... <br /> ...:, _..„ , ,. <br /> .. ,,,.„, <br /> „c__:,:,:.. <br /> 0 4' <br /> 24' <br /> e!!! :. <br /> www.brph.com Copyright 02018 •; .,.., .. Ail?: <br /> ,, - <br /> Architects Engineers,fW Inc.ashingion <<:::.c)�rL�Frl zt6g, _>:, <br /> MO 33td Ave W,Ss.SAD °�dAu oriti6on `IONaL E <br /> L oa,W n 500 AcMec a Na 033235512 ,ti <br /> 42$.6¢14500 :r.,>.:-:. _:.:;, 2 <br /> Enpineee�fg Na 3131 ' Q <br /> CURRENT REVISION 'SYMBOL DATE op <br /> DRAWN DATE SUBTITLE N , • <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE (7.„----; WAgH ACCEPTABILITY JXK 06/12/18 AUTOCLAVE PIPING SECTIONS W2548317 06/12/18 r <br /> 0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 �P �0 o THIS DESIGN RR JEW KED 06/12/18 SHEET co <br /> � � SPECIFICATION IS APPROVED ENGINEER TITLE � <br /> �,�� BRPHNEERSI=CBoeing 777X CWC BUILDING NFA <br /> ® ENGINEERS INC.. APPROVED BY DEPT. DATE JLC 06112/18 M540a <br /> Z)i.w. CHECKED <br /> N0.3137 BUILDING 40-58 <br /> "P�� o APPROVED JOB NO. COMP NO. <br /> F _ 40-58-M540a <br /> c9r6- OF AT0A- �P APPROVED DWG NO. <br /> MECHANICAL MASTER EVERETT, WA 40-58-M540a <br /> R <br />