Laserfiche WebLink
1 <br /> ce <br /> GENERAL NOTES z m <br /> ELECTRICAL LEGEND FOR WINDOWS 'NTH OPERABLE OPENINGS MORE THAN 72" W <br /> ABOVE THE FINISHED GRADE OR SURFACE BELOW, NE Z g-c o <br /> SMOKE ALARM PER R314 AS AMENDED & LISTED PER UL 217 LOWEST PART OF THE CLEAR OPENING SHALL BE 24" J 0I M M <br /> AND NFPA 72. SMOKE ALARMS TO BE PROVIDED IN NEW MINIMUM ABOVE THE FLOOR. EXCEPTIONS: FULLY OPEN a Iv <br /> SA DWEWNG UNITS, AND WHERE ALTERATIONS, REPAIRS O R WINDOWS WHERE A 4' SPHERE MAY NOT PASS THROUGH c� "'= rn <br /> ADDITIONS REQUIRING A PERMIT OCCUR, OR WHERE ONE OR OR WHERE FALL PREVENTION DEVICES ARE PROVIDED PER - a cr <br /> MORE SLEEPING UNITS ARE ADDED OR CREATED IN EXISTING ASTN F 2090 OR R312.2.2. o .1 <br /> DWEWNGS. WORK INVOLVING THE EXTERIOR SURFACES OF THE _ <.z <br /> DWELLING, AND INSTALLATION, ALTERATION OR REPAIRS OF m H a <br /> PLUMBING, ELECTRICAL OR MECHANICAL SYSTEMS ARE EXEMPT PROVIDE SAFETY GLASS PER IRC R308. ,, 3 <br /> FROM THE REQUIREMENTS OF THIS SECTION. SMOKE ALARMS =a <br /> TO BE INTERCa4NECTED EXCEPT WHERE ALTERATIONS OR SKYLIGHTS TO BE DOUBLE PANEL, SHATTER RESISTANT w =" o <br /> REPAIRS DO NOT EXPOSE THE STRUCTURE UNLESS THERE IS APPROVED RIGID PLASTIC, LAMINATED SAFETY GLASS, a N rn <br /> AN ATTIC, CRAW.SPACE OR BASEMENT AVAILABLE FOR FULLY TEMPERED GLASS, HEAT-STRENGTHENED GLASS, = W N g 3 <br /> ACCESS. SMOKE ALARMS ARE TO BE POWERED BY THE OR WIRED GLASS. PROVIDE 4 MINIMUM CURB (OR SELF <br /> BUILDING WRING WITH BATTERY BACKUP. BATTERY POWER IS _0- a <br /> FLASHING ASSEMBLY WITH 3:12 MINIMUM PITCH OR PER w <br /> ALLOWED IN BUILDINGS WITHOUT COMMERCIAL POWER OR WHEN -' ° w <br /> INSTALLED PER R314.2.2. SMOKE DETECTORS SHAL BE MANUFACTURER INSTRUCTIONS). ,�, <br /> INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM NE o E r'E <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS A TUB HOSE BIBBS TO BE BACKER!PREVENTION AND FREEZE c. <br /> OR SHOWER. R314. IONIZATION SMOKE ALARMS: SHALL NOT RESISTANT TYPE. <br /> BE INSTALLED LESS THAN 20 FT HORIZONTALLY FROM A <br /> PERMANENTLY INSTALLED COOKING APPLIANCE. IONIZATION ALL HOEDOWNS. FRAMING ANCHORS & SHEARWALL <br /> 40,-0" SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH SHALL NAILING MUST BE INSPECTED BEFORE COVERING. pp <br /> / NOT BE INSTALLED LESS THAN 10 FT HORIZONTALLY FROM A <br /> " PERMANENTLY INSTALLED COOKING APPLIANCE.PHOTO 0 0 <br /> '. -0 20-0 ELECTRIC SMOKE ALARMS: SHALL NOT BE INSTALLED LESS 0 <br /> / / / THAN 6 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED <br /> lo'-D' 10'-0" O STAIRWAYS PER IRC,R311.7 <br /> COOKING APPLIANCE. R314. <br /> ' ' CARBON MONOXIDE ALARM PER R315 AS AMENDED & LISTED 3 36" MIN. STAIRWAY WIDTH. LANDINGS SHALL HAVE A 36" e . <br /> c° MINIMUM DIMENSION IN THE DIRECTION OF TRAVEL A a <br /> LJ PER UL 2034. COMBINATION CARBON MONOXIDE SMOKE 0 <br /> CS14 <br /> LANDING IS NOT REQUIRED ALARMS SHALL BE LISTED IN ACCORDANCE Wi UL 2034 AND WHERE THERE IS A DOOR AT :� <br /> 2'-6' 2'-3" UL 217. INSTALL OUTSIDE OF EACH SEPARATE SLEEPING Inc. TOP OF AN INTERIOR FLIGHT OF STAIRS, INCLUDING . .s <br /> STAIRS IN AN ENCLOSED GARAGE, PROVIDED THE DOOR <br /> AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON ORS NOT SWING OVER THE STAIRS RISERS TO BE 7 wMAXIMUM HEIGHT <br /> EA(�i LEVEL OF THE DWEWNG AND IN ACCORDANCE WITH5 3 XO 5 3 XO DEPTH, BOTH WITH D MAXIMUM VARATI(NN OF TREADS TO BE 10" ISM <br /> 4LV o s o s THE MANUFACTURER S REC( 4MENDAItONS. WHERE A FUEL <br /> ♦ 'l ♦ ♦ < BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS�/WI <br /> ;;;i,eg i /%,,%/';/,;,,,;,,,;,,,,%,;, : �►.� TREADS WITH SOLID RISERS TO HAVE 3 MINIMUM TO <br /> ,, ATTACHED BATHROOM, A CARBON MONOXIDE ALARM SHALL " , <br /> x6 4x6 x6 BE INSTALLED WITHIN THE BEDROOM. CARBON MONOXIDE 1Y MAX. NOSING OR 11 MINIMUM DEPTH. 4 SPHERE <br /> %; COL % ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE MAY NOT PASS THROUGH OPEN RISERS ON STAIRWAYS <br /> © 6 BUILDING WRING WITH BATTERY BACKUP. CARBON MONOXIDE RISING MORE THAN 30. HANDRAIL REQUIRED IF 4 OR <br /> 00. 0 i , ' ALARMS MAY BE BATTERY POWERED IN BUILDINGS WITHOUT MORE RISERS TO BE INSTALLED BETWEEN 34"-38" ^ m <br /> ;� n » <br /> COMMERCIAL POWER OR WHEN INSTALLED DURING ABOVE NOSING AND HAVE A tY-2 0 GRIP CONTINUOUS o w a, <br /> ,i % ALTERATIONS, REPAIRS AND ADDITIONS PER R315.2.2. o <br /> %� WALL OR NEWEL. I STALL 2x10 BLOCKING RETURNDS TO a N <br /> k WH EXHAUrS PER ERTHOD 1 IRC M15077.3.44, RCANOD WHOLE.HOUSE TILATION NOTES ON BOWEN STUDS AT SIRINGER. ,- " a <br /> ® STUDS TO SUPPORT HANDRAIL BRACKETS FIREBL(X3C o <br /> BED R M #2 BED R M #3 a' v '� MECHANICAL SHEET FAMENDED. SEE E HOUSEOR SIZING <br /> FORMULA, REQUIREMENTS & HEADCLEARANCE. PROTECT ENCLOSED IAIMUM CCES BILE CAL o <br /> c - OPTIONS. WHOLE HOUSE FAN: LABEL SHALL BE AFFIXED TO UNDER STAIR WALLS AND:CEILING 'NTH J GWB. A m w <br /> -7� r- o NE CONTROL THAT READS 'WHOLE HOUSE VENTILATION (SEE FLIGHT OF STAIRS SHALL NOT HAVE A VERTICAL RISE s W <br /> %� / d' OPERATING INSTRUCTIONS)" 2015 IRC M 1507.3.2 LARGER THAN 147' BETWEEN FLOOR LEVELS OR <br /> _ ;' 6'-0" 2'-2' 1'-6' " LANDINGS. STAIRWAYS SHALL BE PROVIDED WITH o w <br /> - y 2-0 8'-4 „� 50 ® 50 CFM MIN. EXHAUST FAN - VENT TO EXTERIOR. ILLUMINATION PER R303.7..: ` � J <br /> S , <br /> , ♦ „ LIGHTING PER R404.1 <br /> o C 26 26 % INSTALLED LIGHTING A MINIMUM OF 75 PERCENT <br /> XTURES SHALL BEPS NHIGH-EFFICACY LAMPS.PERMANENTLY () BATHROOM NOTES <br /> // O N FlREBLOCK TUBS AND SHOWERS PER R302.11. <br /> I O 30 x30 MINIMUM CLEAR SPACE IN SHOWER. 22 MINIMUM <br /> 1 ti 5 BF '4 WIDTH SHOWER DOOR TO OPEN OUTWARD IF HINGED. 30" <br /> %; „ 1 %% ' „' WIDE X 24" DEEP CLEAR SPACE REQUIRED OUTSIDE SHOWER <br /> Q „ I ENERGY CREDITS PER R4Qfi.2 <br /> WARD „' ;; �" SURFACE UPSURES TO BE SAFETY GLASS.6' WITH SHOWER USE CEMENT BOARD ORBENT <br /> S- „ ,. — <br /> 4°BF _�_ EFFlgENT WATER HEATING 5c: 1.5 CREDITS <br /> 10 I' •0 s & P z ,� o , y ♦ WATER HEATING SYSTEM SHALL INCLUDE ONE OF THE CEMENT FIBER BOARD FOR TILE BACKING. VAPOR BARRIER <br /> / Z WARD ,n i fi ,,,, ;<;;,,;,,,,,,,;;;r�,,':;;;s;,;;%,5,.%, ; FOLLOWING.. NOT PERMITTED BEHIND W.P. GWB AT EXT. WALL 2.5 GPM <br /> SHELVES %` i --rt— ——- `� s GAS, PROPANE, OR OIL WATER HEATER WITH A MINIMUM SHOWER FLOW RESTRICTOR. TUB OR SHOWER CONTROL <br /> -r— S & P / • EF OF 0.91.: VALVES TO BE PRESSURE BALANCE OR THERMOSTATIC " <br /> N %;,, „ „ ,,,,,:,,,,_/L ,,,s ,,,,,,,,,,,,•;,,,,,,,,;,,,,,,,;;;;,,;;;.,,,,,,,<,,,, \ MIXING TYPE. 1.6 GAL PER.FLUSFI MAXIMUM TOILETS. 15 <br /> O / SOLAR WATER HEATING SUPPLEMENTING A MINIMUM CLEAR SPACE REQUIRED:EACH SIDE FROM E OF TOILET & <br /> % �' m XATH 1 ` I I , • y, STANDARD WATER HEATER. SOLAR WATER HEATING WILL 21 CLEAR SPACE REQUIRED IN FRONT. INSTALL 2x10 <br /> ' > (6"I 7 I ® =w Iv / I I 401 %% PROVIDE A RATED MINIMUM SAVINGS OF 85 THERMS OR BLOCKING FOR TOWEL BARS UP 48 ABOVE FLOOR OR W <br /> 2000 kWh BASED ON THE SOLAR RATING AND BELOW GILL HEIGHT IF AT WINDOW. INSTALL BLOCKING FOR <br /> \ 14IiE I O I 50 0 2 1 1 o CERTIFICATION CORPORATION (SRCC) ANNUAL T.P. HOLDERS. INSULATE EXTERIOR WALLS ADJACENT TO C D <br /> 3 - ® m z �, '—--i n- ' PERFORMANCE O 0G-300 CERTIFIED SOLAR WATER SHOWERS AND TUBS AND INSTALL AIR BARRIER SEPARATING <br /> c R w %� c o `� HEATING SYSTEMS. THEM FROM THE SHOWIERS.AND TUBS. <br /> OR, <br /> "' 'n A T N ELECTRIC HEAT PUMP WATER HEATER WITH A MINIMUM N N <br /> 's A <br /> l. • `l' "�„'',,,,/,,,�� g EF OF 2.0 AND MEETING THE STANDARDS OF NEEA'S o <br /> ,,., .. , „ �,.,,- ,;;;;,;,<,-��,,,,,,,;;,;;;,;;,,;;,,;,:;;�;,;,;,;� , � FIREBLOCKING .PER R302.11 � �� <br /> NORTHERN CLIMATE SPECIFICATIONS FOR HEAT PUMP op <br /> %`' 13'-0" WATER HEATERS.. 5 INSTALL FlREBLOCKING TO CUTOFF CONCEALED DRAFT °' <br /> ,, 0_ WALK—IN I a , » 3-6 r Q <br /> _, M OPENINGS (VERT. & HORIZ.) IN THE FOLLOWING LOCATIONS: LL 1 <br /> %l WARD i ' ® 3 I 5-4 a FtU11�lO Flxn�tEs FLOW RATR1a Low FLOW FtlllG FIXTURES(WATER aosErs 3 ►°1 <br /> 8-2 / a f�' AND I ULS)AND FITTINGS(FAUCETS AND SHOWERHEADS)SHALL CDIFI.Y WITH THE IN CONCEALED SPACES OF WALLS, VERTICALLY AT CEILING •- <br /> 5'-0" _ '� I I FCII C REQU NTS. &FLO)R LEVELS,HORIZONTALLY AT 10' MAXIMUM = o N <br /> / , I wa <br /> ';; Tn , %% I 1,RE5DE11nAl eAT►�aou LAVATORY Slat FAUCETS 11AX 1 FLOW RATE-1.o INTERVALS, AT INTERCONNECTIONS OF CONCEALED VERTICAL U , <br /> Oa/1 WrER QED I I AO:CRDA�CE AND HORIZONTAL SPA S'(SOFFITS, DROPPED CEILINGS, M A <br /> •%',,; ,5,;>• C ,;�„, ', WITH ASfA A1121&1/CSA D1251. W Op O <br /> �' % 28 PKT 2 RES1D�inAl KITCHEN FAUCETS YAx9M1 FLOW RAZE-1.75 WHIN WHEN TESTED <br /> AND COVE CEILINGS), AT OPENINGS AROUND VENTS, PIPES, m <br /> 1 1 HALF WALL 6 IN ACCORDANCE WITH ASAP DUCTS, CABLES, & WIRES AT CEILING &FLOOR LEVEL WITH <br /> ;Jf c %7%, /, .,- , 1 U P 42" 2 at12 i&1/CSA 61251. AN APPROVED MATERIAL TO RESIST THE PASSAGE OF <br /> OPEN TO I I • " I ENnaL sHow�HEADS MAxp Al FLOW RATE-1.75 GAL/Alpi WHEN TESTED M FLAME & GAS. FlREBLOCKING:TO BE 2x LUMBER OR DOUBLE <br /> -�' I I ACCORDANCE WITH asp THICKNESS OF 1x LUMBER. WITH LAP JOINTS, OR ONE Q <br /> ,. A1121&I/CSA 81251. <br /> /� BELOW z 3-6` 1 I ;�, 3-8 THICKNESS OF WOOD STRUCTURAL PANELS OR <br /> I I , , PARTICLEBOARD (EITHER WITH JOINTS BACKED BY SAME), <br /> - GWB, r <br /> BELOW 2/S-3.0 I I OR X' OR Y" CEMENT MILLBOARD OR BATTS OF Q <br /> MINERAL WOOL OR FIRBERGLASS OR OTHER APPROVED <br /> OPEN TO <br /> ABOVE 4/S-3.0 u •/ u BELOW U MATERIALS SECURELY RETAINED IN PLACE. <br /> MSTR SUITE •7 7/ ;,,,; ,,,,;;,,,, ✓,f.,,<,,, ,7 ;7;;;,;;<,;;, ,,,;,;;,;;,.,;% O EGRESS WINDOWS PER R310 <br /> 0 <br /> ��� ,- o r,' N 6 EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A <br /> ( � J ;, r 0 HEIGHT OF NOT MORE THAN 44 INCHES MEASURED FROM <br /> �/ �./ N .�- THE FINISHED FLOOR TO THE BOTTOM OF THE CLEAR <br /> OPENING. EMERGENCY ESCAPE AND RESCUE OPENINGS <br /> 7 ALL WINDOW HEADERS ON THIS '0 J SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 <br /> " M/B A TH 1 % 4'-t0' + FLOOR TO BE T-On A.F.F. <br /> 1.� �; � � ;/! SQUARE FEET(5.0 S.F. AT GRADE FLOOR) NE MINIMUM <br /> NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES, THE <br /> ;, .W % „ MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES, <br /> ® , <br /> C�50 m z i 4 <br /> ., AND EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE <br /> „ % OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE • J <br /> . .,,f <br /> /;,, <br /> wcn <br /> \ . <br /> ~w „, <br /> `�' USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. O <br /> g , <br /> T :�0 1111111 0 In % . <br /> „ ; T „,,,,; ,,,,.,% (1) ATTIC ACCESS PER R807.1 <br /> 't 22%30" MINIMUM ROUGH FRAMED OPENING LOCATED IN <br /> 2°3°SH 3050 SH 3°5° SH A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. <br /> A. A A <br /> SAF. GLA A INSULATE AND WEATHERSTRIP DOOR. 12" HEIGHT <br /> - INSULATION DAM. 30" MINIMUM CLEAR HEADROOM. <br /> / 1'-10' / 3/i 3'-0" / 3'-114' ` ,, `,A'''4,tir, ''''''. . <br /> ; e vaA %-. <br /> i, �� . <br /> , <br /> LINE OF PORCH BELOW UNE OF PORCH BELOW 'y 4%::,,,, ,,,,, Litrte : H <br /> W <br /> I I <br /> 8'-0" 12'-0" o <br /> -/ 4 / LATERAL ONLY <br /> 20'-0' 20'-O' X o ¢w <br /> JAN 0 9 2019 W 1 <br /> / / t0 Z <br /> L_ QQ z <br /> J <br /> i <br /> 2 G7 <br /> N <br /> W <br /> 0 <br /> C.)UPPER FLOOR PLAN SCALE: Y4' = 1'-O' <br /> 700 SQ. FT. UPPER FLOOR <br /> • <br /> 4 . <br /> 6 <br /> / <br />