GENERAL NOTES z co
<br /> FOR WINDOWS WITH OPERABLE OPENINGS MORE THAN 72' cw.� M
<br /> ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE Z -s co 0
<br /> LOWEST PART OF THE CLEAR OPENING SHALL BE 24" r g M M
<br /> MINIMUM ABOVE THE FLOOR. EXCEPTIONS: FULLY OPEN a- Z II)m
<br /> WINDOWS WHERE A 4" SPHERE MAY NOT PASS THROUGH cD V In
<br /> OR WHERE FALL PREVENTION DEVICES ARE PROVIDED PER Z
<br /> ASTM F 2090 OR R312.2.2. _ $J
<br /> PROVIDE SAFETY GLASS PER IRC R308.
<br /> SKYLIGHTS TO BE DOUBLE PANEL, SHATTER RESISTANT W v o
<br /> APPROVED RIGID PLASTIC, LAMINATED SAFETY GLASS, c~iP
<br /> FULLY TEMPERED GLASS, HEAT-STRENGTHENED GLASS, <n
<br /> OR WIRED GLASS. PROVIDE 4" MINIMUM CURB (OR SELF g z 'if?
<br /> FLASHING ASSEMBLY WITH 3:12 MINIMUM PITCH OR PER _
<br /> MANUFACTURER INSTRUCTIONS). ,a m P
<br /> rn
<br /> HOSE BIBBS TO BE BACKFLOW PREVENTION AND FREEZE
<br /> . RESISTANT TYPE.
<br /> All HOLDOWNS. FRAMING ANCHORS & SHEARWALL
<br /> NAILING MUST BE INSPECTED BEFORE COVERING. °❑o°
<br /> :Lj1=C:
<br /> TRUSSES TO BE DESIGNED & MANUFACTURED PER �.
<br /> ANSI/TPI 1. DESIGN BY STATE LiCENSED ENGR. & a
<br /> 16'-0" 16'-0" MANUFACTURED AT APPROVED PLANT. SUBMIT
<br /> TRUSS DESIGN DRAWINGS TO BUILDING OFFICIAL FOR U
<br /> 6'-O' 6'-0" APPROVAL PRIOR TO INSTALLATION & SHIP
<br /> -Pi0 ANG /- DRAWINGS TO JOB SITE WITH TRUSSES. DESIGN ' $ '`
<br /> ,,, �, W DRAWINGS TO INCLUDE ALL LOADS, LUMBER INFO., . ,, '
<br /> q Q a 15.74) CONNECTIONS, HANGERS, PERMANENT RUM.
<br /> \_ 1 )1 I -V� �_ / SPECIFI BRACING ED PER R802�.10.1R�TRUS S TOATED BEBRACED
<br /> • 4x10 DF#2 4x10 DF#2 II i ; II4x10 DF#2 4x10 DF#2 '� TO PREVENT ROTATION & TO PROVIDE LATERAL
<br /> \ R- 02 R- 04 M R- 04 R- 02 / STABILITY PER TRUSS DESIGN DRAWINGS, BUILDING
<br /> \ I / PLANS, & PER BUILDING LATERAL ENGINEERING.
<br /> II I II FIELD CUTS OR MODIFICATION OF TRUSSES NOT ^ m
<br /> \ z I` Z / PERMITTED WITHOUT ENGINEER'S CALCS. /OTLS. o cx QP
<br /> — \ "� Ili _ AND PRIOR APPROVAL BY THE BUILDING a. o
<br /> *ic6=
<br /> `� a II I� II I� II / DEPARTMENT. BOTTOM CHORD OF TRUSSES TO BE Co o `�
<br /> eNt ft. \ CO x •� N x •� / N HELD OFF OF NON-BEARING INTERIOR WALLS WITH d-
<br /> =c `" ' ,� N ' I �" _ SIMPSON STC ROOF TRUSS CLIP OR EQUIVALENT. o ;
<br /> Ni ® I ® II/ .of GABLE END TRUSS TO HAVE VERTICAL MEMBERS
<br /> N \ m I: ; Ace 24'o.c. FOR SIDING. GABLE END TRUSS TO BE m w
<br /> .c Er_ 0 / N SHEATHED & NAILED PER WALL BELOW.
<br /> \ a _ II NI H AI II / — o J
<br /> \ 1' SIMPSON /
<br /> II \W (2)2x6 RF#p LUS26-2 / II ATTIC ACCESS PER R807.1
<br /> 1 L, J L -IL J (TYP) O 22"x30" MINIMUM ROUGH FRAMED OPENING LOCATED IN
<br /> \4% SIMP� r -I r • l r / A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION.
<br /> LUS26-II � I! II11
<br /> . INSULATE AND WEATHERSTRIP DOOR. 12' HEIGHT
<br /> 1 (TYP) I C / I INSULATION DAM. 30" MINIMUM CLEAR HEADROOM.
<br /> I \:,,,:k.' 1 1 1
<br /> I 6 „ A
<br /> L €5 I I1 i
<br /> / f ROOF & ATTIC VENTILATION
<br /> Li— \� a/ D AU. VENTS TO BE SCREENED W/Y' CORROSION
<br /> 1 r——I I `�'= I / - o II RESISTANT METAL MESH. (3) 2"0 HOLES PER VENT
<br /> c i i� I I a BLOCK = 7.0 SQ. IN. NET AREA (74%). LOCATE VENT
<br /> N 8 I O I II \ c`'I; / II I O I i BLOCKS AT CORNERS & EVENLY BETWEEN FOR ATTICS. W
<br /> I I &M o / I I �„ a INSTALL VENT BLOCK EA. RAFTER SPACE FOR CD
<br /> — Co a -J (2)Zx6 R F#8 LRIDGE L ` ,I J L _ __, o — CATHEDRAL
<br /> VENTILATING SHALLTHEBEs MINIMUM NET 50 OF THE AREA OF
<br /> A= q� 0 = _ —I =11
<br /> —N = (2)2x6 HF r r r A _ THE VENTED SPACE. EXCEPTION: THE MINIMUM NET
<br /> r R-099\ I,' ! \ 1 FREE VENTILATION AREA SHALL BE 1/300 OF THE Q N N
<br /> .�-- 1� — r - _ —AI 411
<br /> co VENTED SPACE PROVIDED THE FOLLOWING CONDITION o
<br /> I�' — \—'I IS MET: AT LEAST 40%AND NOT MORE THAN 50% ° rn
<br /> / \ p OF THE REQUIRED VENTILATING AREA IS PROVIDED BY °'
<br /> HIP JACKS HIP JACKS ¢ I
<br /> • II �P"/ I \f • VENTILATORS LOCATED IN THE UPPER PORTION ED w t 3Z 24 0/c / \ 0 24 0/c THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS = o N/ I \ SHALL BE LOCATED NO MORE THAN 3 FEET BELOW -J I
<br /> o 1HE RIDGE OR HIGHEST FONT OF 1HE SPACE, C, �W coI I—.: — — ——= rI MEASURED VERTICALLY, WTH THE BALANCE OF THE .W to m `�
<br /> — —— I I I 1 I —- REQUIRED VENTILATION FRONDED BY EAVE OR
<br /> / I. \ CORNICE VENTS. MERE THE LOCATION OF WALL OR
<br /> B I� �' I € - �;, �. ,�!,• I II ROOF FRAMING MEMBERS CONFLICTS WITH THE >---
<br /> INSTALLATION OF UPPER VENTILATORS, INSTALLATION 0
<br /> 7 24 o �� ,mim it \ \ MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST
<br /> / 24 o c 24 0
<br /> Q ( ( POINT OF THE SPACE SHALL BE PERMITTED.
<br /> ,. \ 0
<br /> —., II / I i
<br /> a DORMER FRAMED ON \ II --
<br /> T ROOF DECK. OPEN TOEAVE BAFFLES:
<br /> ` . / STAIRWELL. FOR LIGHT. \ .,�
<br /> =o^ .; ; j , =c FOR AIR PERMEABLE INSULATIONS IN VENTED ATTICS,
<br /> co I / f SLOPED SHELF t SLOPED SHELF . \ I A BAFFLE SHALL BE INSTALLED ADJACENT TO SOFFIT
<br /> h.
<br /> gmtco AND EAVE VENTS. BAFFLES SHALL MAINTAIN AN
<br /> `x / — x \ N Ix OPENING EQUAL OR GREATER THAN THE SIZE OF THE
<br /> /II _ l, i . IN VENT. THE BAFFLE SHALL EXTEND OVER THE TOP OF
<br /> — / 0/HANG 20i0PIC ! ` 12030"IC I \ — THE ATTTIC TED ITO BE ANY STHE OLID BAFFLE
<br /> MATE SHALL AL BE
<br /> PERM/ (2)2x6 HF#2 I t1I I I 12• R-11 \ WSEC.R402.2.3
<br /> ac,/ II II \ BEAMAIN=A770 SF. UNIT) J
<br /> . / 4x6 DF#2 (2)2x6 HF#2 (2)2x6 HF ' (2)2x6 HF#2 (2)2x6 HF#2 4x6 DF#2 \ 770_ 300= 2.57 SF VENTILATION REQ'D L.L. 0 CI ;
<br /> R- 01 R -03 R -05 I I, I 1 R -05 R -03 R- 01 LOWER PART OF ATTIC:
<br /> IT .. �`#—� tSF NET EAIAF5 0 ROOF VENTS NEAR WALL LINE 0.347
<br /> I I ( \ I INSTALL 20 VENT BLOCKS* 0.0492 SF NET EA. =
<br /> li 1
<br /> 1 ( I 0.98 SF NET
<br /> 0/HANG UPPER PART OF ATTIC: =
<br /> INSTALL 3 AF50 ROOF VENTS 0.347 SF NET EA.
<br /> PREFAB TRU jES 0 24"o/c4 I PREFAB TRUSFS 0 24"0/c4 1.04 SF NET
<br /> 2I 6:12 PITCH 61-0" PATTERN Z I 6:12 PITCH 61-0' PATTERN I c, TOTAL VENTING PROVIDED::: .2.71 SF
<br /> II
<br /> kg I I o A 1 I 1 It PORCH ATTIC (EA UNIT)
<br /> I El I ( I I AREA = 36 SF
<br /> 36_ 150= 0.24 SF VENTILATION REQ'D,
<br /> LLOWER PART OF ATTIC:
<br /> — —(._. _ _ L _ _ ____I_ _ _ J INSTALL 6 VENT BLOCKS.0.0492 SF NET EA. = a
<br /> 0/HANG , , , , 0/HANG 0.3 SF NET
<br /> 4-0 / 4-0 UPPER PART OF AMC: C) ( z
<br /> INSTALL 0 GABLE VENTS 0 1.04 SF NET EA. = Cr1.0 a
<br /> 16'-0" 8'-0" 16'-0" 0 SF NET �n 3
<br /> TOTAL VENTING PROVIDED: 0.3 SF
<br /> L-w
<br /> r—
<br /> x N ¢w
<br /> U V (L
<br /> tDZ
<br /> —I N cri
<br /> 0-. QQ Z_
<br /> J
<br /> CD N
<br /> W o
<br /> 0
<br /> ROOF FRAMING PLAN SCALE: Y4' = ii-0.
<br /> 5
<br /> 6
<br /> 8 :,
<br /> 11/4. J