My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 RIVERSIDE RD 2020 INFARM INDOOR URBAN FARMING Plans 2022-11-29 (3)
>
Address Records
>
RIVERSIDE RD
>
607
>
INFARM INDOOR URBAN FARMING
>
Plans
>
607 RIVERSIDE RD 2020 INFARM INDOOR URBAN FARMING Plans 2022-11-29 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2022 1:53:39 PM
Creation date
8/4/2021 2:47:13 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
607
Tenant Name
INFARM INDOOR URBAN FARMING
Permit
B2002-008
Year
2020
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES <br /> 1. GC TO PROVIDE REQUIRED PORTABLE FIRE EXTINGUISHERS IN OCCUPANCIES <br /> AND LOCATIONS AS REQUIRED PER SECTION 906 IN THE INTERNATIONAL FIRE <br /> CODE. MOUNTING HEIGHTS TO MEET THE PROVISIONS OF ANSI A117.1 - 308 <br /> (48" MAX). CABINET SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, Nelco Architecture, Inc. <br /> CORRIDORS, PASSAGEWAYS, OR AISLES. LOCATE CABINET(S) 75-FOOT <br /> MAXIMUM TRAVEL DISTANCE TO REACH THE EXTINGUISHER, (1) 2A <br /> EXTINGUISHER TO COVER MAXIMUM FLOOR AREA OF 3,000 SF. LOCATIONS TO <br /> BE REVIEWED WITH OWNER AND ARCHITECT PRIOR TO INSTALLATION. <br /> 2. CENTER LOCATION OF NEW WALL CONSTRUCTION ON EXISTING COLUMNS, 1200 Fifth Ave. <br /> PIER,JOISTS OR WINDOW MULLION, AS SHOWN. <br /> 3. RACKING SOLUTION IS NOT KNOWN AT THIS TIME-A SEPARATE, FUTURE Suite 1300 <br /> RACKING PERMIT WILL BE SUBMITTED. FUTURE RACKING PERMIT WILL Seattle, WA 98101 <br /> INCLUDE ADDITIONAL EXIT SIGNS REQUIRED SPECIFIC TO RACKING LAYOUT. Phone: (206)408-8500 <br /> WWW.NELSONWORLDWIDE.COM <br /> EGRESS CODE SUMMARY <br /> A. MAX. TRAVEL DISTANCE B OCCUPANCY: 300' (TABLE 1017.2) <br /> TRAVEL DISTANCE B OCCUPANCY: 200' (WITHOUT SPRINKLERS) (TABLE 1017.2) <br /> MAX. TRAVEL DISTANCE S-1 OCCUPANCY: 400' (TABLE 1017.2.2) <br /> MAX. TRAVEL DISTANCE S-1 OCCUPANCY: 200' (WITHOUT SPRINKLERS) <br /> (TABLE 1017.2) <br /> B. MAX. COMMON PATH OF EGRESS TRAVEL: 100° (TABLE 1006.2.1) <br /> MAX. COMMON PATH OF EGRESS TRAVEL: 75' (>30,WITHOUT SPRINKLERS) <br /> (TABLE 1006.2.1) <br /> OCCUPANCY LOAD: <br /> (IBC 1004.1 TABLE 1004.1.2) <br /> SUITE 1 WAREHOUSE - S (EXISTING/NEW) 23,790 SQ FT/ 500 = 48 <br /> SUITE 2 WAREHOUSE - S (EXISTING/NEW) 28,405 SQ FT/500 = 57 <br /> TOTAL = 105 <br /> EXIT REQUIREMENTS: <br /> - - -1 (IBC 1006 TABLE 1006.2.1 & 1006.3.1) <br /> -4.......irNUMBER REQ'D NUMBER PROVIDED <br /> 0 0 0 0 0 0 0 0 0 0 0 0 SUITE 1 WAREHOUSE 2 3 <br /> SUITE 2 WAREHOUSE 2 6 <br /> C C C C C C C C ` I CLIENT: <br /> LEGEND <br /> ITI PTN E <br /> immiimmimm <br /> NEW EXS PARTITIONNGARTI, SEEIO SHEET TOR MAIN A8-1 <br /> PANATTONI <br /> ----4-: <br /> _ EXI11 <EXIT> INTERNALLY ILLUMINATED EXIT SIGNAGE W/ BATTERY <br /> 11 O o BACKUP PER IBC SECTION 1013, CONFIRM OPERATION OF DEVELOPMENT <br /> hi li EXISTING. ADD NEW WHERE NOT EXISTING. ARROW = COMPANY, LLC <br /> DIRECTION INDICATOR, IF REQUIRED. <br /> 7O O7 PROVIDE TACTILE EXIT SIGN ADJACENT TO EACH EXIT <br /> 0 o DISCHARGE DOOR COMPLYING WITH ICC A117.1, AS 900 SW 16TH STREET, SUITE 330 <br /> ---I I SUMMARIZED ON 703/T1.2. ADD NEW WHERE NOT EXISTING. RENTON, WA, 98057 <br /> mot_ `-1 '�` n NOTE: EXIT SIGN PLACEMENT SHALL BE SUCH THAT NO <br /> I EXIT POINT IN AN EXIT ACCESS CORRIDOR IS MORE THAN - PROJECT: <br /> 100' OR THE LISTED VIEWING DISTANCE FOR THE GLACIER PEAK <br /> 1 m 0 I SIGN, WHICHEVER IS LESS. INFARM <br /> • c PTN. / i _ EXIT SIGNS, INCLUDING EXISTING SIGNS, SHALL SPECIFY <br /> r COL. A <br /> i j A MINIMUM 90-MINUTE UNINTERRUPTED SUPPLY POWER <br /> ----------------I---..--- - <br /> PER IBC SECTION 1013.6.3. <br /> O EXIT 1� rQ-� --- — — — <br /> (2) EXIT SIGNS; ONE HIGH (t20' 0") AND ONE LOW 607 RIVERSIDE ROAD <br /> in <br /> (±8-0 ) SHALL BE PROVIDED AT EACH EXTERIOR DOOR. <br /> EVERETT, WA 98201 <br /> C o 0 C C C 0 C C C C C o FIRE EXISTING FIRE DEPARTMENT ACCESS DOOR PROVIDED AT <br /> INTERVALS LESS THAN 100' SPACING AROUND PERIMETER Description: No: Date: <br /> OF BUILDING FOR PERMIT 01/4/2020 <br /> DIRECTION OF TRAVEL <br /> ko — / _PATH OF EGRESS <br /> 1l <br /> _ START POINT <br /> A w w I .� <br /> a o C o C o C C o I U C C-' C o 0 <br /> z _ Q � COMMON PATH OF TRAVEL TERMINATION POINT <br /> Iii <br /> —r i H 3 <br /> o i o HIGH, LED BAY LIGHT FIXTURE - FINAL LAYOUT TO BE <br /> 14 EXIT` CONFIRMED BY ELECTRICAL DESIGN BUILD <br /> -I HATCH INDICATES "NIGHT LIGHT" FOR EGRESS ILLUMINATION <br /> NOT LESS THAN 1 FC PER IBC SECTION 1008.2.1 WITH 90 MIN. <br /> I] 0 I O 0 0 ' 0 0 0 0 O I 0 0 0 <br /> UNINTERRUPED EMERGENCY POWER PER 1008.3.4. <br /> t I J I <br /> - - - - - - - - - - - - - - - — — — — — — — — — ___I__- - — --- — ® I — — — — — — — — <br /> I , <br /> E T 1- — — — KEY NOTES 0 <br /> I <br /> . o 0 0 0 0 0 o 0 0 i 0 0 0 1. EXISTING ACCESSIBLE ENTRANCE/EXIT <br /> Li <br /> N I I N I SUITE 1 SUITE <br /> I I 2. NEW TENANT DEMISING WALL, FOR DETAIL SEE 1/A8.1. PROVIDE GWB ON SUITE <br /> , v v 1 SIDE ONLY. <br /> Yin w <br /> 1 C I �, 3. EXISTING COLUMN,TYP. <br /> I 2‘. <br /> Z , — <br /> z <br /> --- -----------_1------------ — — — — — — — — — — — — — — — — — - 1 i — — — -- — — — — ' �- — — — — -�- — — — — 4. EXISTING DOCK HIGH OVERHEAD DOOR,TYP. SEAL: <br /> C o C 0 0 0 0 0 0 i p 0 0 o <br /> ri- <br /> _ I Lu <br /> -J 5. APPROXIMATE LOCATION OF EXISTING SANITARY SEWER LINE <br /> - - �- - - - - - - r- - - - - - 2LJ - - - - -I - - - - - - I- - - - - - ,- - - - -1-> - - - - -� - - - - 1 >- l - - <br /> i I 5 i ce O 6. EXISTING EXTERIOR STAIR,TYP 10194 <br /> �ill r�� 1 i I <br /> ARREC HITERED <br /> miriw�.cilk IICI I 7. EXISTING FIRE RISER/ELECTRICAL ROOM <br /> I I <br /> 8. NOT USED. \ir16AM EGA L <br /> sa <br /> 0 L----}-o --, C o i o (0 C I STATE OF WAS�i11�FTON <br /> I 1 EXIT 14 ' 14 EXIT L > n EXIT 14 I 9. EXISTING ACCESS AISLE AND ACCESSIBLE PARKING STALLS <br /> , <br /> _ o 0 0 0 0 0 0 0 0 0 0 0 0 0 o Oo o © 10. EXISTING PARKING STALLS,TYP <br /> o 0 0 / o 0 0 0 0 o I I I I o 0 0 0 0 0 0 0 0 0 0 0 0 o o I l <br /> 0 13 0i 13 10 13 I 11. EXISTING ACCESSIBLE ROUTE: RAMP WITH MAX SLOPE OF 1:20, CITY STAMP: <br /> C C C C C C C C C C % j C C O • <br /> �� ` , 4 �� MAX CROSS SLOPE OF 1:48; MIN 36" WIDE <br /> 9 <br /> 6 <br /> 12. EXISTING CONCRETE SIDEWALK <br /> 13. EXISTING LANDSCAPING,TYP. REPLACE ANY LANDSCAPE DAMAGED DURING <br /> CONSTRUCTION. <br /> // I 14. EXISTING FIRE DOOR CONVERTED TO NEW EXIT. NEW INTERNALLY <br /> ILLUMINATED EXIT SIGN, PER LEGEND. NEW EXTERIOR LIGHT FIXTURE ABOVE SHEET NAME: <br /> — — - -- DOOR AT LANDING. THE LIGHT FIXUTRE SHALL PROVIDE A MINIMUM 90 MINUTE ARCHITECTURAL <br /> UNINTERRUPTED SUPPLY POWER PER IBC SECTION 1008.3.4. SEE IBC SECTIONS SITE/EGRESS DEMISING <br /> —---------------------------- -- ----- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1008.3.2 ITEM 5 AND 1010.1.6. <br /> 15. EXISTING SEMI-HEATED WAREHOUSE SPACE. UNIT HEATERS PROVIDING FREEZE PLAN <br /> PROTECTION ONLY; MODIFY EXISTING GAS FIRED HEATING UNIT(S)TO COMPLY <br /> 1 ARCHITECTURAL SITE/EGRESS/DEMISING PLAN WITH 2O15 WSEC: MAXIMUM 8 BTU'S PER SF. Proj. No. 20.0000104.000 Reviewed By: PA/PM <br /> ED SHEET No: <br /> A0.1 1" = 30' <br /> A1 . 1 <br />