<br /> 302/303 FLOOR SURFACES &CHANGES IN LEVEL 404 DOORS continued 502/503 PARKING AND PASSENGER LOADING ZONES continued 604 WATER CLOSETS&TOILET COMPARTMENTS continued 609 GRAB BARS continued 703 SIGNAGE continued NELsoN
<br /> GALVANIZED MOUNTING BOLTS ANSI/ICC A117.1 604.5-GRAB BARS(REFERENCE DETAILS)
<br /> ANSI/ICC A117.1 %03 CHANGES IN LEVEL(REFERENCE DETAIL) ANSI/ICC A117.1 404.2.E DOOR HARDWARE - A. For water closets not located in toilet stalls,the following grab bars shall be provided,33"- ANSI/ICC A117.1 609.8-STRUCTURAL STRENGTH OVERHEAD SIGNS
<br /> A. Changes in level up to 1/4"may be vertical and without edge treatment A. Handles,pulls,latches, locks,and other operating devices shall have a shape that is easy 1' 0" F.i 1' 0" 36"above the finish floor: A. Grab bars and mounting devices shall meet the following requirements: A. CHARACTERS AND NUMBERS ON OVERHEAD SIGNS SHALL BE SIZED ACCORDING TO
<br /> B.Changes in level between 1/4"and 1/2"shall be beveled with a slope no greater than 1:2. to grasp with one hand and does not require tight grasping,tight pinching,or twisting of '" '" 609.8 Allowable stresses shall not be exceeded for materials used where a vertical or THE VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ.
<br /> 1. Side wall horizontal: 42"in length minimum, 12"max from rear wall,extending 54"
<br /> the wrist to operate. in horizontal force of 250 lbs. is applied at any point on the grab bar,fastener mounting 1. FOR SIGNS HIGHER THAN 70"A.F.F.,CHARACTER SIZE SHALL BE 2"MINIMUM PLUS
<br /> min.from rear wall 1„ •
<br /> 1. Lever-operated mechanisms,push-type mechanisms,and U-shaped handles are . 1v, device,or supporting structure. s PER FOOT OF VIEWING DISTANCE ABOVE 15 FEET. Nelco Architecture Inc,
<br /> ¢ 2.Side wall vertical: 18"in length minimum,bottom of bar located 39"min/41"max. 1
<br /> 2 acceptable designs. NO MD STATE above the floor,centerline 39"min/41"max from rear wall 1.Shear stress induced by application of 250 lb.shall be less than allowable shear 1. THE MINIMUM HEIGHT IS MEASURED USING AN UPPER CASE LETTER"I".
<br /> a- \ 2.When slidin doors are full o en,o eratin hardware shall be ex osed and usable PARKING DISABLED
<br /> 71- g y p p g p ~ PARKING �" stress for material used. If connection between grab bar and mounting bracket is 2. LOWER CASE LETTERS ARE PERMITTED.
<br /> '" / from both sides. PEivrr 3. Back wall: 36"in length minimum,extend from centerline of water closet 12"min.on
<br /> REQUIRED side closest to the wall,24"min.on transfer side. considered to be fully restrained,then direct and torsional shear stresses shall be totaled
<br /> \ / 3. Hardware required for accessible door passage shall be mounted between 34"and VAN \ for the combined shear stress,which shall not exceed the allowable shear stress. ANSI/ICC A117.1 703.3-703.5-RAISED CHARACTERS,BRAILLE,&PICTOGRAMS
<br /> 48"above finished floor. O p ACCESSIBLE ANSI/ICC A117.1 604.E FLUSH CONTROLS 2.Shear force induced in a fastener or mounting device from application of 250 lb. A. Raised characters shall comply with section 703.3 and shall be duplicated in braille
<br /> Detail Z 2 Z A. Flush controls shall be hand operated or automatic,and located on the open side of the shall be less than allowable lateral load of either the fastener or mounting device or the complying with section 703.4.
<br /> ANSI/ICC A117.1 404.2.7.1-DOOR CLOSERS ' 0 z O z p p 1200 Fifth Ave.
<br /> J c9 PRE-MANUF,SIGN c7 PRE-MANUF.SIGN supporting structure,whichever is the smaller allowable load. B. Letter and numerals shall be raised 1/32",upper case,sans serif and shall be Suite 1300
<br /> ANSI/ICC A117.1 302.2-CARPET _ r water closet. Hand operated flush controls shall comply with Section 309.
<br /> A. Door closers shall be adjusted so that from an open position of 90 degrees,the time o O en 4"DIA.STEEL p 0 V) 4"DIA STEEL 3.Tensile force induced in a fastener by a direct tension force of 250 lb.plus the accompanied by grade 2 Braille.
<br /> A. Carpet provided on a floor surface shall be securely attached; have a firm pad or backing, POSTW/CAP POST WI CAP pp g plus °perviewing Seattle WA 98101
<br /> or nopad;and have a level loop,textured loop, level cutpile,or level cut uncutpile required to move the door to an open position of 12 degrees shall be 5 seconds minimum. E., 00 Tr) O7 maximum moment from the application of 250 lb.shall be less than the 1. Raised character hei ht: minimum to 3" foot of distance
<br /> p, p, / p FINISH GRADE p �� FINISH GRADE ANSI/ICC A117.1 604.7 DISPENSERS(REFERENCE DETAIL)
<br /> texture. Maximum pile thickness shall be 1/2".Exposed edges of carpet shall be fastened allowable withdrawal load between the fastener and the supporting structure. above 21 feet. Phone: (206)408-8500
<br /> ANSI/ICC A117.1 404.2.7.2-SPRING HINGES A.Toilet paper dispensers shall comply with Section 309.4 and 609.3.Where the dispenser is 609.E Grab bars shall not rotate within their fittings. 2. Braille shall be contracted
<br /> to floor surfaces and have trim along the exposed edges. I SET POST IN CONC. SET POST IN CONC. located above thegrab bar,the outlet of the dispenser shall be located 24"min-36"max 9 (grade 2); shall be located below title corresponding
<br /> A. Door spring hinges shall be adjusted so that from the open position of 70 degrees,the I i p text. WWW.NELSONWORLDWIDE.COM
<br /> door shall move to the closed position in 1.5 seconds minimum. i I ., _ from the rear wall.Where the dispenser is located below the grab bar,the outlet of the ANSI/ICC A117.1 609.5-ELIMINATING HAZARDS 3. Pictograms shall be accompanied by the equivalent verbal description placed
<br /> ANSI/ICC A117.1 302.3 GRATINGS Co , NOTE:INSTALL SIGN AT THE HEAD OF iO NOTE:INSTALL SIGN AT ALL ACCESSIBLE dispenser shall be located 24"min-42"max from the rear wall.The outlet of the dispenser A. Grab bars and adjacent wall surfaces shall be free of sharp or abrasive surfaces. Edges directlybelow the pictogram.
<br /> A.If gratings are located in walking surfaces or along accessible routes,then they shall have :� EACH ACCESS AISLE LOCATED ADJACENT '-' PARKING STALLS.SPACES DESIGNATED shall comply with Table 603.6. p g
<br /> ANSI/ICC A117.1 404.2.8 and IBC with WA STATE AMENDMENTS- DOOR OPENING FORCE I I I p y shall be rounded. 1. The border dimension of the pictogram shall be 6"min, in height.
<br /> spaces no greater than 1/2"wide in one direction. IJ ; TO AN ACCESSIBLE PARKING SPACE. FOR VAN PARKING SHALL HAVE 1. Dispensers that control deliveryor do notpermit continuous paper flow shall not p 9
<br /> B.If gratings have elongated openings,then they shall be placed so that the long dimension A. The maximum force for pushing or pulling open doors shall be as follows: ADDITIONAL SIGN"VAN ACCESSIBLE" p p p
<br /> be used. 54" MIN 1. Fire doors shall have the minimum opening force allowable by the appropriate MOUNTED BELOW.MOUNT ON WALL OF ANSI/ICC A117.1 703.3.12-FINISH AND CONTRAST
<br /> is perpendicular to the dominant direction of travel. administrative authority. Detail Detail BLDG WHEN POSSIBLE,
<br /> A. Characters and their background shall have a nonglare finish.Characters shall contrast
<br /> 1. Other doors ANSI/ICC A117.1 604.9-WHEELCHAIR ACCESSIBLE COMPARTMENTS 39"-41"
<br /> 505 HANDRAILS with their background,with either light characters on a dark background,or dark
<br /> a. Exterior hinged,slidingor foldingdoor: 10.0 lb.max. A.Wheelchair accessible compartments shall comply with Section 604.9. Toilet
<br /> 305 CLEAR FLOOR SPACE gHandrail to extend Handrail to extend horizontally compartments shall complycharacters on a light background.
<br /> b. Interior hinged doors: 5.0 lb. max. p with Section 604.9.2.1 or 604.9.2.2 as applicable. 36" MIN.
<br /> horizontally at top extension at top and bottom extension 12" MAX MII
<br /> ANSI/ICC A117.1 305.2 SIZE AND APPROACH c. Interior sliding or folding doors: 5.0 lb.max. Bottom rail to provide edge ANSI/ICC A117.1 703.3.10&703.3.11-MOUNTING LOCATION AND HEIGHT(REFERENCE DETAIL)
<br /> A. Minimum clear floor space for a wheelchair and occupant shall be 30"wide x 48"long. These forces do not apply to the force required to retract latch bolts or disengage other protection 36" MAX 36" MAX I co A. Characters and their background shall have a nonglare finish.Characters shall contrast
<br /> Clear floor space shall be centered on the element it serves. devices that may hold the door in a closed position. If vertical rise is greater than 6" 24" MIN y1.r with their background,with either light characters on a dark background,or dark
<br /> Exception: Interior or exterior automatic doors complyingwith Section 404.3 of ICC Handrail to extend with slope at r, \ a c I ��� on wide side
<br /> p p then bottom rail to provide edge z \ characters on a light background.
<br /> A117.1. bottom extension protection z M IIoN I M B. Where a tactile sign is mounted next to a door, it shall be placed to the latch side of the
<br /> DETAILS) Tc, No, door wherever possible.Where a tactile sign is placed adjacent a double door,the sign
<br /> 307 PROTRUDING OBJECTS (REFERENCE '� ¢ x¢ min-
<br /> gill�� M M shall be to the right hand door.If there is no wall space to the right,signs shall be placed
<br /> 406 CURB RAMPS (1) 1' o' - -
<br /> TREAD DEPTH M M • C \ g • imiiii
<br /> \ \ V \ on the nearest adjacent wall. Exception: Door mounted signs shall be permitted on the
<br /> ANSI/ICC A117.1 307 GENERAL II / II �� /� push side on the doors with closers and without hold open devices.
<br /> A.Objects projectingfrom walls (for example,telephones)with their leadingedges between ANSI/ICC A117.1 406-SLOPE(REFERENCE DETAIL 1' 0" ,-,z ./ F. v
<br /> p P ) 9 ) //: T. C. Raised characters shall be 48"minimum above the floor,measured to the baseline of the
<br /> 27"-80"above the finished floor shall protrude no more than 4"into walks, halls, A.Slopes of curb ramps shall comply with 406 / %/ lowest raised character and 60"maximum above the floor,measured to the baseline of
<br /> corridors,passageways,or aisles. Freestanding objects mounted on posts or pylons may B.Maximum slopes of adjoining gutters,road surface immediately adjacent to the curb ramp, �� \ I Side Wall Grab Bar for Water Closet Rear Wall Grab Bar for Water Closet
<br /> or accessible route shall not exceed 1:20. ` \ \ \�' \ the highest raised character.
<br /> overhang12"maximum from 27"-80"above the round or finished floor. Protruding 1' 6 g signage p y approach within 3"of
<br /> 9 9 \ � \\�\\\ X \ \` / \ / WC D. Mountin location for such si na a shall be so that a erson ma objects shall not reduce the clear width of an accessible route or maneuvering space. signage without encountering protruding objects or standing within the swing of a door.
<br /> ANSI/ICC A117.1 406.4-WIDTH(REFERENCE DETAIL) IWir
<br /> Handrail at Stair Handrail at Ramp
<br /> A.The minimum width of a curb ramp shall be 36",exclusive of flared sides. 1 1/2" 1 1/4"to 2" 42" MAX 42" MAX 15"MAX IBC with WA STATE AMENDMENTS 1101.2.6-INTERNATIONAL SYMBOL OF ACCESSIBILITY
<br /> 4" MAX. CI EAR WID H ANY AMOUNT ANSI/ICC A117.1 406.3-SIDES OF CURB RAMPS(REFERENCE DETAIL) HAND SHOWER/ A. Where the International Symbol of Accessibility is required,it shall be proportioned
<br /> �� LOBBY Protruding Dispenser Protruding Dispenser Recessed Dispenser ■ 24"SLIDE BAR complying with ANSI/ICC A117.1 Figure 703.6.3.1.All interior and exterior signs depicting
<br /> r _ ■ A.If a curb ramp is located where pedestrians must walk across the ramp or where it is not Below Grab Bar Above Grab Bar the International Symbol of Accessibility shall be white on a blue background.
<br /> protected by handrails or guardrails,it shall have flared sides;the maximum slope of the
<br /> .1 1 flare shall be 1:10 w.A.
<br /> '� Handrail Section 605-URINALS 36" MIN.
<br /> / 602 DRINKING FOUNTAINS -, 11,J'i7w� ANSI/ICC A117.1 605-URINALS3"MAX. 1 1/2"MA
<br /> j-���i t-�ii Adjoining Slope Shall A.Accessible urinals shall com I with Section 605.n7 ANSI/ICC A117.1 602.1-GENERAL p y " N• x _
<br /> O Not Exceed 1:20 1'■ " ____ ■V, If xIslessthan46" A.Accessible drinking fountains shall comply with Sections 602 and 307. ■ = XCLIENT.' \ \ ANSI/ICC A117.1 605.2-HEIGHT&DEPTH(REFERENCE DETAIL iooz J X Then The Slope Of The Flared Flared side ) zI I ¢ A.Urinals shall be stall type or wall hung with a tapered,elongated rim at 17" �n MAX ,.g 2 Sides Shall Not Exceed 1:12 ANSI/ICC A117.1 602.2-CLEAR FLOOR SPACE M N /A.A clear floors ace com I in w Section 305 maximum above the finished floor.The rim shall extend a minimum of 13 "from the - �olirEN
<br /> r\ p p y g / positioned for a forward approach to m IIIio ., l`/^r\ 36„mm the drinking fountain,shall be provided. Knee&toe space complying with Section 306 wall. M ^
<br /> Detail Detail shall be provided.The clear floor space shall be centered on the drinking fountain. �-���� I
<br /> ANSI/ICC A117.1-605.3-CLEAR FLOOR SPACE(REFERENCE DETAIL) C6 .. ..
<br /> EXCEPTIONS: / \ • • •. •.
<br /> A.A clear floor space 30"wide by 48"deep minimum shall be provided in front of urinal to
<br /> 1. Drinking fountains for standing persons. CONTROL AREA
<br /> allow forward approach.
<br /> 308 & 309 REACH RANGES AND OPERABLE PARTS2. Drinking fountains primarily for children's use. 608.3.1 Side Wall Grab Bar for Shower 6083,1 Rear Wall Grab Bar for Shower Shower Floor Plan/Seat Letter&numbers on signs shall have a width
<br /> Ramp(1:12 Max,Slope) 3.In existing building,existing drinking fountains providing a parallel approach 1.This space shall adjoin or overlap an accessible route. agShall Have Detectable Warnings 2. Urinal shields that do not extend beyond the front edge of the urinal rim may be to height ratio of between 3:5&1:1 and
<br /> ANSI/ICC A117.1 308 HEIGHT (REFERENCE DETAIL) and contrasting color. complying w/Section 305,centered on the drinking fountain shall be permitted.
<br /> provided with 29"clearance between them. 610 SEATS a stroke-width to height ratio between PANATTO N I
<br /> A. Unobstructed front approach-48"max.to 15"min.A.F.F.Controls located in an alcove 4.Where specifically permitted by the administrative authority,a parallel approach
<br /> 3. Urinals installed in alcoves deeper than 24"require a maneuvering area of at 1:5&1:10. Letters and numbers shall be raised
<br /> >24"deep must have 36"clear floor width. 1:10 Max.slopeshall be permitted that replace existing parallel approach drinking fountains. ANSI/ICC A117.1 610.2 SHOWER COMPARTMENT SEATS DEVELOPMENT
<br /> B. Unobstructed side approach 48"max.to 15"min.A.F.F.Controls located in an alcove least 36"minimum wide,centered on fixture. 1/32",upper case,sans serif or simple serif
<br /> Standard Curb Ramp A. The height of the shower compartment seats shall be 17"minimum and 19"maximum .. type and shall be accompanied with
<br /> >15"deep must have 60"clear floor width. 36"Min. ANSI/ICC A117.1 602.3-OPERABLE PARTS above the bathroom floor measured to the topof the seat.
<br /> C. Electrical&communication system receptacles shall be mounted no less than 15"above Adjoining Slope Shall A. Operable parts shall comply with Section 309. ANSI/ICC A117.1 605.4 FLUSH CONTROLS(REFERENCE DETAIL) grade 2 Braille,raised characters shall be at COMPANY LLC
<br /> B. Allowable stresses shall not be exceeded for materials used where a vertical or ,
<br /> Not Exceed 1:20 Controls shall comply with ANSI/ICC A117.1 309 OPERABLE PARTS E.
<br /> least 5/8" 3"high plus 1/8"per foot of
<br /> the floor. horizontal force of 250 pounds is applied at any point in the seat,fastener mounting viewing distance above 21 feet.
<br /> ANSI/ICC A117.1 602.4 SPOUT OUTLET HEIGHT 48" MIN. device or support structure. 900 SW 16TH STREET, SUITE 330
<br /> ANSI/ICC A117.1 309-OPERABLE PARTS A. Wheelchair accessible spout outlets shall be 36 inches max. aff.Standing person spout ,{ /
<br /> Operable parts shall be operable with one hand and shall not require tight grasping, pinching, Location of Typical outlets shall be 38 inches min.&43 inches max.aff. \ \ r - International Symbol Detail RENTON WA, 98057
<br /> or twistingof the wrist.The force required to activate operable arts shall be S.OIbs Parking Access Aisle I 702 ALARMS
<br /> q p x "= I <II of Accessibility
<br /> El I
<br /> maximum. ANSI/ICC A117.1 602.5 SPOUT LOCATION xQ 2 oM I
<br /> A. Spout shall be located 15 inches min.from the vertical support and 5 inches max.from I ANSI/ICC A117.1 702.1 GENERAL PROJECT:
<br /> Rams(1:12 Max. the front edge of the drinking fountain,including bumpers. ^ vv-•
<br /> o> \ I- A.When required,visual alarms shall be provided in each of the following areas,as a
<br /> p Slope) 8 �` minimum: rest rooms and anyothergeneral usage areas e. Light GLACIER PEAK -
<br /> 1:12 Max.slope Shall Have Detectable Warnings g ( g., meeting rooms), g 8" MAX
<br /> r" Thermostats,Etc.
<br /> and contrasting color, ANSI/ICC A117.1 602.6-WATER FLOW - 14" MIN hallways,lobbies,and any other area for common use. I N FARM
<br /> Curb Ramp Parallel to Curb w
<br /> Note: If Slope is 1:20 or less A. Spout shall provide a flow of water 4 inches min. in height. The angle of the water stream Detail Detail z w
<br /> { Detail no contrasting color or texture spouts within 3 inches of the front of the drinkingfountain shall be 30 degrees max. Accessible audible and visible alarms and notification appliances shall be installed in w '-
<br /> from fliVA
<br /> is requiredp g accordance with NFPA 72. cn a r
<br /> and from spouts between 3 inches&5 inches from the front of the drinking fountain shall ¢ D
<br /> x¢ be 15 degrees max.,measured horizontally relative to the front face of the drinking 606 LAVATORIES m =
<br /> o Y ANSI/ICC A117.1 406.10-DIAGONAL CURB RAMPS NFPA 72-AUDIBLE ALARMS w v
<br /> fountain. o F- 607 RIVERSIDE ROAD
<br /> Co 0 0 �� oo A.If diagonal curb ramps have returned curbs or other well-defined edges,such edges shall ANSI/ICC A117.1 606.3&606.2 HEIGHT&CLEARANCES(REFERENCE DETAILS) A.If provided,audible alarms shall produce a sound that exceeds the prevailing equivalent
<br /> z = be parallel to the direction of pedestrian flow.The bottom of diagonal curb ramps shall A. Lavatories shall be mounted with the rim or counter surface no higher than 34"above the sound level in the room or space by at least 15 dba or exceeds any maximum sound level ¢ _ _ 0 0 EVERETT, WA 98201
<br /> o O have 48"minimum clear space outside active traffic lanes of the roadway.If diagonal curb 5"MIfinished floor. with a duration of 60 seconds by5 dba,whichever is louder. C7 �n
<br /> p 9 5"MAX ¢ ,�
<br /> N E ~ ramps areprovided at marked crossings,the 48"clears ace shall be within the markings. 1. Lavatories shall extend 17"minimum from the wall. = Description: No: Date:
<br /> 9 p 9 / s' B.Sound levels for alarm signals shall not exceed 120 dba.
<br /> If diagonal curb ramps have flared sides,they shall also have at least a 24"long segment r �, o �, 2.Clearance of 27"minimum shall be provided from the finished floor to bottom of o LL \+
<br /> of straight curb located on each side of the curb ramp and within the marked crossing. o apron. NFPA 72-VISUAL ALARMS 1 FOR PERMIT 01/4/2020
<br /> -<r ll >< 3. Knee clearance of 27"high minimum shall extend 8"minimum under the edge of the Convenience Outlets
<br /> I ¢ g g A.Visual alarm signal appliances shall be integrated into the building or facility alarm system.
<br /> ANSI/ICC A117.1 406.11 ISLANDS I °' lavatory, 30"wide minimum,and 19"deep minimum. If single station audible alarms areprovided then single station visual alarm signals shall Detail Data,Tel.,Etc.
<br /> FULL LENGTH MOP/BROOM STAINLESS STEEL SOLID HAT/COAT HOOK IIIII
<br /> ` 9 g g
<br /> MIRROR HOLDER SHELF PLASTIC A.Any raised islands in crossings shall be cut through level with the street or curb ramps at `n,, 4.Toe clearance of 9"minimum shall be provided for the full depth of the be provided.
<br /> both sides and a level area at least 48"long and 36"minimum wide between the curb I�I_I lavatory. Visual Alarm a• ppliances shall have the following features:
<br /> BENCH ramps in the part of the island intersected by the crossings. \ 1.The lamp shall be a xenon strobe type or equivalent. 804 KITCHENS AND KITCHENETTES
<br /> ANSI/ICC A117.1 606-DEPTH
<br /> Forward Approach 2.The color shall be clear or nominal white(i.e.unfiltered or clear filtered white light). ANSI/ICC A117.1 804.5.E-REFRIGERATOR/FREEZER
<br /> 403 ACCESSIBLE ROUTE WALKING SURFACES A. Each sink shall be a maximum of 6-1/2"deep. 3.The maximum pulse duration shall be two-tenths of one second with a maximum Combination refrigerators and freezers shall have at least 50%of the freezer compartment
<br /> 410 PLATFORM LIFTS 603 TOILET ROOMS duty cycle of 40%. (The pulse duration is defined as the time interval between initial shelves,including the bottom of the freezer 54 inches(1370mm)maximum above the floor
<br /> IBC 1104 LOCATION o o and final points of 10%of max signal) when the shelves are installed at the maximum heights possible in the compartment.A clear
<br /> ANSI/ICC A117.1 410.1-GENERAL ANSI/ICC A117.1 603.2.2- DOORS _ 4.The intensity shall be a minimum of 75 candela. floor space,positioned for a parallel approach to the space dedicated to a
<br /> A.At least one accessible route within the site shall be provided from public transportation A.Platform lifts shall comply with Section 410 and ASME A18.1 listed in Section 105.2.6. A. Doors shall not swing into the clear floors ace or clearance for an fixture. E
<br /> p Y 9 p y 17" MIN to 5.The flash rate shall be a minimum of 1 Hz and a maximum of 3 Hz refrigerator/freezer,shall be provided.The centerline of the clear floor space shall be offset
<br /> stops,accessible parking and accessible passenger loading zones,and public streets or o 6.The appliance shall be placed 80"above the highest floor level within the space 24 inches(610 mm)maximum from the centerline of the dedicated space.
<br /> Platform lifts shall not be attendant operated and shall provide unassisted entry and exit re o
<br /> sidewalks to the accessible building entrance served. from the lift. ANSI/ICC A117.1 603.2-CLEARANCES ,Q o \ r or 6"below the ceiling,whichever is lower.
<br /> A.The accessible fixtures and controls required shall be on an accessible route.An +' clez I a.In lar a rooms ands ces exceedin 100'across,without obstructions 6'
<br /> ANSI/ICC A117.1 403.5-CLEAR WIDTH � C� 0 9 g
<br /> ANSI/ICC A117.1 410.2-LIFT ENTRY unobstructed turning space complying with 304 shall be provided within an accessible i
<br /> �.� - '' flo ° above the finished floor,such as auditoriums,devices may be place around the
<br /> A.The minimum clear width shall be 32"at a point for a max. length of 24"and 36" z z z
<br /> A. Lifts with doors or gates shall comply with Section 410.2.1. Lifts with ramps shall comply toilet room.The clear floor space at fixtures and controls,the accessible route,and the spa
<br /> continuously, per Table below. rill chi perimeter,spaced a maximum 100'apart,in lieu of suspending appliances from the
<br /> with Section 410.2.2. turning space may overlap;however;the only turning space provided shall not be located Ceitt, ^ \ L - - - 902 DINING SURFACES&WORK SURFACES
<br /> ceiling.
<br /> within a stall. G�■ °i `r 19" 7.In general, no place in any room or space shall be more than 50'from the
<br /> MINIMUM ANSI/ICC A117.1 410.2.1-DOORS AND GATES o MAX/ / ANSI/ICC A117.1 902.2 CLEAR FLOOR SPACE
<br /> SEGMENT SEGMENT IIa signal(measured in a horizontal plane).
<br /> A. Doors and gates shall be low energy power operated doors or gates complying with ANSI/ICC A117.1 603.3&606-LAVATORIES AND MIRRORS 8" MIN ." MAX 48" MIN 8. Noplace in common corridors or hallways shall be more than 50'from the signal.
<br /> A.A clear floor space complying with Section 305,positioned for a forward approach,shall be
<br /> LTO1-'n vviuin Y 9
<br /> lessthan or equal 32" Section 404.3. Doors shall remain open for 20 seconds minimum. End door clear opening A.If lavatories and mirrors are provided,then at least one of each shall comply with / / provided. Knee and toe clearance complying with Section 306 shall be provided.
<br /> to:24" width shall be 32 inches minimum.Side door clear opening width shall be 42 inches 603.3&606.Accessible lavatories and mirrors shall not be located within toilet stalls III 17" MIN
<br /> greater than:24" 36" minimum. unless other accessible lavatories and mirrors are provided in the toilet room. 703 SIGNAGE ANSI/ICC A117.1 902.4-HEIGHT
<br /> Exception: A.The tops of accessible tables and counters shall be 28"minimum,and 34"maximum,
<br /> Lifts serving two landings maximum and having doors or gates on opposite sides shall be ANSI/ICC A117.1 603.3-MIRRORS(REFERENCE DETAIL) \- WHERE APPLICABLE above the finished floor.
<br /> IBC with WA STATE AMENDMENTS 1101.2.1-CLEAR WIDTH permitted to have self closing manual doors or gates. A. Mirrors shall be mounted with the bottom edge of the reflecting surface 40" A. Signs which designate permanent rooms and spaces shall comply with the
<br /> A. Clear width of an accessible route shall comply with Table above.For exterior routes of maximum A.F.F. Mirrors not located above lavatoreis,sinks or counters shall be requirements listed below for:
<br /> travel,the minimum clear width shall be 44". ANSI/ICC A117.1 410.2.2-RAMPS mounted with the bottom edge of the reflecting surface 35"maximum above the floor. �\ 1. Raised and Braille Characters,and Pictograms
<br /> A. End ramps shall be 32 inches minimum in width.Side ramps shall be 42 inches minimum \ in 2. Finish and Contrast 903 BENCHES
<br /> ANSI/ICC A117.1 403.5.2-PASSING SPACE in width. ANSI/ICC A117.1 603.6-OPERABLE PARTS \ 7 jr \ Exception: Employee name signs are not required to comply.
<br /> A.If an accessible route is less than 60"in width,then passing spaces of at least 60"x60" A. Operable parts on towel dispensers and hand dryers shall comply with Table below. ��- ' -� \ \ ANSI/ICC A117.1 903.2-CLEAR FLOOR SPACE
<br /> shall be provided at 200'max.spacing. ANSI/ICC A117.1 410.3-FLOOR SURFACES I I \ x o WHERE APPLICABLE A.a clear floor space complying with section 305, positioned for parallel approach to the SEAL:
<br /> B.The minimum clear width for two wheelchairs to pass is 60" A. Floor surfaces of platform lifts shall comply with Section 302 z = z = ¢ , _ A.Signs which provide direction to,or information about,functional spaces of the building bench seat shall be provided.
<br /> Maximum 0.5" 2" 5" 6" 9" 11" i' ob ' 'D rn b
<br /> Reach Depth in shall comply with the requirements listed below for:
<br /> ANSI/ICC A117.1 307.2 ANSI/ICC A117.1 410.4-PLATFORM TO RUNWAY CLEARANCE ir, N in N F.', 1. Character Proportion ANSI/ICC A117.1 903.3-SIZE
<br /> Maximum A.Accessible routes shall have 80"min.clear head room. A. The clearance between the platform sill and the edge of any runway landing shall be 1 1/4 Max 48" 46" 42" 40" 36" 34" N N 2. Character Height A. Benches shall have seats 42"minimum in length and 20"minimum and 24"maximum in
<br /> Reach Height g g 10194
<br /> inch maximum •���������������������\������������������������ � � ����� 3. Finish and Contrast depth. 1 (111
<br /> REC TERED
<br /> ANSI/ICC A117.1 403.3-SLOPE Exception: Building directories,menus,and all other signs which are temporary are not AR HITECT
<br /> A. Running slope shall not exceed 1:20. ANSI/ICC A117.1 410.5-CLEAR FLOOR SPACE 604 WATER CLOSETS &TOILET COMPARTMENTS WALL MOUNTED LAVATORY MOUNTED IN required to comply. ANSI/ICC A117.1 903.4-BACK SUPPORT
<br /> B. Cross slope shall not exceed 1:48 A. Clear floor space of platform lifts shall comply with Section 305. LAVATORY COUNTER A.The bench shall provide for back support or shall be fixed to a wall.Back support shall be
<br /> ANSIJICC A117.1 604.3 CLEARANCES WHERE APPLICABLE (REFERENCE DETAIL) 42"minimum in length and shall extend from a point 2"maximum above the seat surface to
<br /> ANSI/ICC A117.1 410.6-OPERABLE PARTS A. Element and spaces of accessible facilities which shall be identified by the International a point 18"above the seat surface.
<br /> A. Controls forplatform lifts shall comply with Section 309. A.Clear floor space for water closets not in stalls shall be provided as follows: ANSI/ICC A117.1 606.6-EXPOSED PIPES AND SURFACES EC
<br /> p y Clearance around a water closet shall be 60"minimum in width,measured perpendicular A. Hot/cold water and drain Symbol spof aces
<br /> designatedility are: 1
<br /> 404 DOORS pipes under lavatories shall be insulated or otherwise STATE OF WASl�i1N�TON
<br /> from the sidewall. Clearance around the water closet shall be 56"minimum in depth, configured to protect against contact. 1. Parking spaces as reserved for persons with disabilities. jj
<br /> ANSI/ICC A117.1 404.2.1-DOUBLE-LEAF DOORWAYS 502/503 PARKING AND PASSENGER LOADING ZONES measured perpendicular from the rear wall. Reference Detail 2. Accessible passenger loading zones.
<br /> / p p ( ) B. There shall be no sharp or abrasive surfaces under lavatories.
<br /> A. Doorways with two independently operated leaves shall have at least one active leaf that B. No door swings are allowed in clear floor area. 3.Accessible entrances when not all are accessible(inaccessible entrances shall have 905 STORAGE
<br /> meets the requirements in 404.2.2 and 404.2.3 ANSI/ICC A117.1 502-PARKING SPACES ANSI/ICC A117.1 606.4-FAUCETS directional signage to indicate route to nearest accessible entrance). ANSI/ICC A117.1 905.2-CLEAR FLOOR SPACE
<br /> 4. Accessible toilet and bathing facilities when not all are accessible. A clear floor sp
<br /> ace Accessible car parking spaces shall be 96"minimum in width.Van parking spaces shall be 56" MIN. (WALL MOUNTED W.C.) A. Controls shall be operable with one hand and shall not require tight grasping,pinching,or complying with Section 305 shall be provided.
<br /> ANSI/ICC A117.1 404.2.2-CLEAR WIDTH 132"minimum in width. 59" MIN. (FLOOR MOUNTED W.C.) twisting of the wrist.
<br /> A. Doorways shall provide a clear opening of 32"minimum,with the door open 90°. ANSI/ICC A117.1 703.2.4-CHARACTER HEIGHT(REFERENCE DETAIL)
<br /> EXCEPTION:Van parking spaces shall be permitted to be 96"minimum in width where B. The force required to activate controls shall be no greater than 5 lb. ANSI/ICC A117.1 905.3 HEIGHT CITY STAMP:
<br /> 1. Clear opening shall be measured between the face of the door and opposite stop. Height:The uppecase letter"I"shall be used to determine the allowable height of all
<br /> the adjacent access aisle is 96"minimum in width. C. Lever operated,push type,and electronically controlled mechanisms are examples of 5 Accessible storage elements shall comply with at least one of the reach ranges specified in
<br /> 2. Openings more than 24"in depth shall provide a clear opening of 36"minimum. B. Parking access aisles shall be 60"wide.Van accessible access aisles shall be 96"wide. 12" MAX acceptable designs. characters of a font and shall be a minimum of g"and 2"maximum. Section 308.
<br /> C.Surface slope shall not exceed 1:48 in all directions D. If self-closing valves are used the faucet shall remain open for 10 seconds minimum.
<br /> ANSI/ICC A117.1 404.2.3-MANEUVERING CLEARANCES AT DOORS EXCEPTION:Where separate tactile and visual characters with the same information are
<br /> / (Note: no built up curb ramp may be located in an accessible parking access aisle.) P ANSI/ICC A117.1 905.4 OPERABLE PARTS
<br /> Provide level (1:48 max.slope)and clear maneuvering area at doors as follows: -
<br /> provided,the height of the tactile upper case letter"I"shall be permitted to be."minimum. Operable parts of storage facilities shall comply with Section 309.
<br /> A. Front approach pull side 60"min.width& 18"min. beside strike edge ' 609 GRAB BARS
<br /> ANSI/ICC A117.1 502.7-SIGNAGE(REFERENCE DETAIL) r _ \ 6"MAX.
<br /> Front approach push side-48"min width& 0"beside strike edge A. Each accessible parking space must have individual vertically mounted or suspended sign. I '- IN / y ANSI/ICC A117.1 609.3.2-SIZE AND SPACING ANSI/ICC A117.1 703.2.5-CHARACTER WIDTH
<br /> (12"@strike if door has both a closer and a latch) Required van accessible spaces must be designated. I z A. Diameter or width of gripping surface shall be 1-1/4"to 2",or the shape shall provide an A. Width:The uppercase letter"O"shall be used to determine the allowable width of all AUTOMATIC TELLER MACHINES
<br /> B. Hinge side approach pull side-60"min.width;36"min.beside strike edge or-54"min. v _ equivalent gripping surface. characters of a font,and shall be 55%min.and 110%max.of the height of the
<br /> I I , q 9 pP 9 9
<br /> width;42"min. beside strike edge / \ Q l o 1. The space between grab bars and adjacent walls shall be 1 1/2" uppercase"I"of the font. ANSI/ICC A117.1 305 CLEAR FLOOR SPACE
<br /> B. Characters and symbols on such signs shall be located 60"minimum above the ground. N
<br /> Hinge side approach push side 42"min.width&22"min.beside hinge edge ANSI/ICC A117.1 503.5 VERTICAL CLEARANCE \ ' I D \ 11`� Z A. Floor space shall comply with Section 305 to allow a forward,parallel approach or both.
<br /> (48"min. width if door has both a closer and a latch) A. Provide minimum vertical clearance of 114"at accessible passenger loading zones and o re I
<br /> C. Latch side approach pull side-48"min.width and 24"min.beside strike edge along at least one vehicle access route from site entrances and exits. - - - L - - - - \ z \ N
<br /> (54"min.width if door has a closer) L_ ANSI/ICC A117.1 308 HEIGHT
<br /> Latch side approach push side-42"min.width and 24"min. beside strike edge ANSI/ICC A117.1 503-PASSENGER LOADING ZONE 7 / Detail \ �� \ -r w i \ o o \ jI \ A. Operable parts shall be placed within one or more of the reach ranges specified in Section ACCESSIBILITY DETAILS
<br /> 48min.width if door has a closer) 6' NIN. z 308,summarized earlier in this sheet.
<br /> ( " A. Passenger loading zones shall provide an access aisle at least 60"wide and 20 ft long `- 2 w
<br /> 0
<br /> adjacent and parallel to the vehicle pull-up space.If there are curbs between the access TOILET PARTITION TOE CLE4RANCE
<br /> ANSI/ICC A117.1 404.2.4- THRESHOLDS AT DOORWAYS aisle and the vehicle pull-up space,then a curb ramp complying with 4.7 shall be ANSI/ICC A117.1 604.4- HEIGHT(REFERENCE DETAIL) �� ' ¢ b ¢ o o o
<br /> A. Maximum threshold height: 1/2". Raised thresholds and floor level changes shall be provided.Vehicle standing spaces and access aisles shall be level with surface slopes not A.The height to the top of the toilet seat shall be 17"- 19"above floor. ° a- o '"\ \
<br /> beveled with a slope no greater than 1:2 exceeding 1:48 in all directions. 1.Seats shall not be sprung to return to a lifted position. ' Q THIS SHEET IS PROVIDED FOR YOUR CONVENIENCE. IT CONTAINS SELECTIONS FROM Proj. No: 20.0000104.000 Reviewed By: PA/PM
<br /> THE CURRENT ACCESSIBILITY REFERENCED STANDARDS(2015 IBC CHAPTER 11 WITH WA
<br /> IBC with WA STATE AMENDMENTS 1101.2.5-FLUSH CONTROLS \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\��\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ STATE AMENDMENTS AND ANSI/ICC A117.1),BUT IS NOT INTENDED TO BE A COMPLETE
<br /> A. Hand operated flush controls shall comply with Section 309,except the R-TOILET SEAT R-PAPER TOWEL S-ELECTRIC HAND R-PAPER TOWEL R-SANITARY NAPKIN R-WASTE OR EXHAUSTIVE COPY OF THE CURRENT ACCESSIBILITY STANDARDS.
<br /> maximum height above the floor shall be 44". COVER DISPENSER DISPENSER/WASTE DRYER DISPENSER DISPENSER RECEPTACLE
<br /> RECEPTACLE A N 3
<br /> ANSI/ICC A117.1 604.7- DISPENSERS- REFERENCE DETAIL.THE OUTLET OF THE DISPENSER SHALL COMPLY WITH TABLE 603.6
<br />
|