My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-58 Plans 2022-11-09 (3)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-58 Plans 2022-11-09 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 10:02:42 AM
Creation date
8/5/2021 3:34:10 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
M1811-038
Year
2019
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DRAWING LIST PROCESS and CONTROL 1 ROL. SYMBOLS 1V1BOL.S IDENTIFICATION LETTERS <br /> SHEET DRAWING/EQUIPMENT CATEGORIES LINE DESIGNATIONS VALVE SYMBOLS ABB. 1ST LETTER 2ND OR SUCCEEDING LTTRS <br /> 0 EQUIPMENT BLOCK DIAGRAM A ANALYZER ALARM <br /> INDICATES PROCESS CONNECTION PROCESS OPEN(TYPICAL) P B BURNER,COMBUSTION <br /> 1 LEGEND <br /> C CONTROL,CHECK CONTROL/CLOSED <br /> 2 DOOR CONTROL,BRIDGE CONTROL INDICATES ANALOG ELECTRICAL CONNECTION El PROCESS CLOSED(TYPICAL) 4' <br /> - RELIEF VALVE CR CONTROL RELAY PILOT OPERATED SAFETY <br /> 3 NITROGEN PRESSURIZING SYSTEM CV CHECK VALVE <br /> 4 VACUUM SYSTEM INDICATES DISCRETE ELECTRICAL CONNECTION <br /> GATE VALVE D DIRECTIONAL DIVIDING,DIFFERENTIAL <br /> SPRING LOADED SAFETY DCV DIRECTIONAL CONTROL VALVE <br /> 5 AUTOCLAVE VESSEL COOLING SYSTEM // // INDICATES PNEUMATIC SIGNAL RELIEF VALVE IN-LINE E ELECTRIC ELEMENT <br /> 6 AUTOCLAVE VESSEL HEATING SYSTEM Itli GLOBE VALVE PATTERN <br /> F FLOW <br /> r, INDICATES SOFTWARE OR DATALINK <br /> 7 COOLING WATER SYSTEM-HOT&COLD WELLS SPRING LOADED SAFETY H HAND HIGH <br /> • BALL VALVE RELIEF VALVE ANGLE <br /> HOA HAND-OFF-AUTO <br /> 8 COOLING TOWER SYSTEM PATTERN <br /> INTERFACE SYMBOLS I CURRENT INDICATOR <br /> 9 COMPRESSED AIR I I BUTTERFLY VALVE <br /> I/P CURRENT TO PNEUMATIC <br /> MXXXX PIPE IS CONTINUED ON DRAWING M- VACUUM BREAKER TRANSDUCER <br /> XXX,FLOW IS TO THAT DRAWING. PINCH VALVE L LEVEL LIGHT, LOW <br /> MXXX / PIPE IS CONTINUED FROM M MOTOR <br /> C X ` DRAWING M XXX, FLOW IS FROM PNEUMATIC ACTUATOR MCC MOTOR CONTROL CENTER <br /> \ THAT DRAWING. <br /> LIMIT STOP N NEEDLE <br /> MXXX PIPE IS CONTINUED ON DRAWING <br /> M-XXX,FLOW CAN BE IN EITHER 0 OPEN <br /> PIPING NOMENCLATURE X DIRECTION. PNEUMATIC POSITIONER --I LIMIT VALVE CLOSING <br /> 02 OXYGEN <br /> • BP BLACK PIPE-STANDARD WEIGHT LIMIT VALVE OPENING <br /> AI <br /> P PRESSURE,PROCESS PNEUMATIC,PORT <br /> UP S S <br /> •BP80 BLACK PIPE-SCH80 INSTRUMENT SYMBOLS XXX ELECTROPNEUMATIC POSITIONER PNL PANEL <br /> 1 1 Q EVENT TOTALIZE <br /> / \ SOLENOID ACTIVATED CYLINDER RECORDING, REGULATING, <br /> I GP40 GALVANIZED PIPE-SCH40 M — ACTUATOR R RELIEF,RELAY <br /> (0)0( N.O. NORMALLY OPEN MOTOR DRIVEN ACTUATOR S SAFETY SWITCH <br /> SST STAINLESS STEEL TUBING GRAPHICS DISPLAY STATION <br /> 00 N.C. NORMALLY CLOSED X DIRECTIONAL CONTROL VALVE <br /> ... S/S START STOP <br /> '.'��"� LOCK OUT,TAG OUT OPT F.O. FAIL OPEN S T TEMPERATURE TRANSMITTER <br /> LOTO INSTRUMENT LOCALLY MOUNTED VARIABLE FLOW RESTRICTOR <br /> XXX F.C. FAIL CLOSED UV UNDER VOLTAGE <br /> '"`Ili POINT OF CONNECTION SOLENOID OPERATED VALVE V VIBRATION VALVE <br /> V 1. L.O. LOCKED OPEN <br /> HIS VR VARIABLE RESTRICTION DEVICE <br /> XXX INSTRUMENT PANEL MOUNTED L.C. LOCKED CLOSED S MANUAL OVERRIDE <br /> I/O SYMBOLS: W WELL <br /> Y COMPUTED <br /> V_SH INSTRUMENT BACK OF PANEL MOUNTED THREE-WAY SOLENOID VALVE <br /> THE CONTROL SYSTEM IN WHICH XXX FULL TAG NUMBER WILL BE: NEEDLE VALVE Z POSITION <br /> <k> <br /> ANALOG INPUT THE I/O CONNECTS TO IS <br /> 0 PMP - 7 10 E <br /> INDICATED UNDERNEATH THE I/O <br /> CLG PLC--.-- I/O TO CONTROL SYSTEM - <br /> SYMBOL. EAST/WEST DESIGNATION CHECK VALVE SYSTEM ABBREVIATIONS <br /> IDENTIFICATION PLUG VALVE <br /> ACWR AUTOCLAVE COOLING WATER RETURN <br /> AO ANALOG OUTPUT CLG PLC=AUTOCLAVE SUB- EQUIPMENT CATEGORY ACWS AUTOCLAVE COOLING WATER SUPPLY <br /> SYSTEMS PLC AS INDICATED ON TYPE OF DEVICE SHOWN BY RELIEF DEVICE AFF ABOVE FINISHED FLOOR <br /> EMCS AUTOCLAVE#(0 FOR COMMON, x ►— , VESSEL PASS THRU APF ABOVE PIT FLOOR <br /> DRAWINGSO PRODUCED BY 1 FOR AUTOCLAVE#1,ETC) Y X=SIZE(INCHES) APV AUTOCLAVE PROCESS VACUUM <br /> CONCEPT SYSTEMS. <br /> DI DIGITAL INPUT Z Y=ORIFICE AREA(SQ. INCHES) APVE AUTOCLAVE PROCESS VACUUM EXHAUST <br /> EMCS=ENERGY MANAGEMENT Z=SET PRESS.(PSIG) REGULATED SIDE PRESSURE APW AUTOCLAVE PROCESS VACUUM VENT <br /> AC CONTROL SYSTEM DDC CONTROL VALVE CA COMPRESSED AIR <br /> CONTROLLER AS INDICATED ON MISCELLANEOUS SYMBOLS CTWR COOLING TOWER WATER RETURN <br /> DO DIGITAL OUTPUT DRAWINGS PRODUCED BY _ _ <br /> CTWS COOLING TOWER WATER SUPPLY <br /> HONEYWELL. 0 0 G NATURAL GAS <br /> CLG PLC FLEXIBLE CONNECTOR TRIPLE DUTY VALVE GN2 NITROGEN GAS <br /> INTERLOCK LOGIC I N v �- I I I��I AUTOMATIC FLOW BALANCING VALVE <br /> AC=AUTOCLAVE PLC SYSTEM AS -.F— MCCWR MOTOR CAPSULE COOLING WATER RETURN <br /> INDICATED ON DRAWINGS / RAINCAP MCCWS MOTOR CAPSULE COOLING WATER SUPPLY <br /> PRODUCED BY AUTOCLAVE © ELECTRICAL INTERLOCK <br /> MANUFACTURER,ASC PROCESS <br /> SYSTEMS. III II SILENCER <br /> MAT.CLASS CHANGE OR LINE HYDRAULIC POWER UNIT SYMBOLS PUMP and COMPRESSOR SYMBOLS <br /> SIZE CHANGE <br /> ® BOEING/PDM INTERFACE <br /> SHOWN BY PENETRATION OR PDM BOEING I- — _ — <br /> / NOZZLE PENETRATION#/SIZE — — <br /> CONE STRAINER \ . I STRAINER CENTRIFUGAL PUMP,FAN <br /> � � AIR BLEED <br /> ANNUBAR FLOW SENSOR FILTER <br /> DRAIN TO RESERVOIR <br /> MATERIAL CLASS 0 <br /> FLOATING BALL FLOW INDICATOR I I STRAINER,"r'TYPE PROPORTIONING PUMP <br /> HI BLIND FLANGE r — — — —1 1 1 FOUR WAY, <br /> 100D DUCTWORK TI THERMOMETER 1 TWO POSITION VALVE, <br /> 125D MALLEABLE IRON/CARBON STEEL XXX PI I TT NORMALLY OPEN PISTON PUMP <br /> 150C ANSI CL.150 CARBON STEEL <br /> XXX PRESSURE GAUGE PRESSURE RELIEF <br /> TT TEMPERATURE TRANSMITTER FOUR WAY, <br /> 300C ANSI CL.300 CARBON STEEL XXX XTHREE POSITION VALVE, <br /> 3000C 3000#CARBON STEEL RUPTURE DISK OR SAFETY HEAD FOR T CENTER POSITION NORMAL r EJECTOR <br /> STATIC MIXER PRESSURE RELIEF <br /> M SPRING PILOT <br /> 0O IMPELLER AGITATOR �� PROGRESSIVE CAVITY PUMP <br /> INSULATION CODES and SYMBOLS --[1:1}— REDUCER CONCENTRIC <br /> VSD VARIABLE SPEED DRIVE MANUAL OVERRIDE MOTOR <br /> SAMPLE CONNECTION/PORT <br /> AP ACOUSTICAUPERSONNEL PROTECTION VARIABLE RESTRICTION <br /> AC ACOUSTICAL <br /> PP PERSONNEL PROTECTION VENTURI METER / SOLENOID DIAPHRAGM PUMP <br /> FAN <br /> NI NON-INSULATED <br /> VARIABLE DISPLACEMENT <br /> 2PP/NI USED WHEN A LINE IS PARTIALLY PISTION PUMP PRESSURE <br /> INSULATED&PARTIALLY VORTEX METER CHECK VALVE COMPENSATED. <br /> NON-INSULATED MCC <br /> MOTOR CONTROL CENTER WITH - _ <br /> INDICATES WHERE A LINE CHANGES FROM XXX SWITCH MAGNETIC FLOW METER 0INSULATED TO NON-INSULATED - - GAUGE <br /> ---1:1—H REDUCER-ECCENTRIC ' < ,, <br /> Y ,, , V of w'A,sv <br /> PSD PUMP SUCTION DIFFUSER � „� �''" r . � �� �, C� <br /> MANUAL AIR VENT Qtils <br /> 0 . ( W �_ <br /> Q <br /> PRESSURE/TEMPERATURE PORT ; �� �� <br /> \ t <br /> Li AIR RELEASE VALVE(FOR SELF- V WATER SURFACE LEVEL www.brptE:ccom Copyright02018 <br /> PRIMING PUMPS) �,. � ��'� <br /> Architects Engineesteers, Inc. ����FGITER��1��w <br /> U DRAIN AUTOMATIC AIR VENT 1902033rdAvew,satno Deem*of en *' .'SIOVAL ���.••�"" <br /> �.^ I 125�5DQ sfungien,seas Engteadry Ha 60323s512 Y'�<. ; , ; , <br /> a <br /> E fM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE wq s ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE a <br /> of H, JXK 06/12/18 W2548317 06/12/18 0 <br /> 0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 y �Q o THIS DESIGN ANDIOR CHECKEDP & ID LEGEND & ABBREVIATIONS4. * SPECIFICATION IS APPROVED JEW 06/12/18 SHEETco <br /> RCHITECTS ENGINEER TITLE Boeing 777X CWC BUILDING Ner ,artiri,iti ` Ar-V �� wEERSINC. APPROVED BY DEPT. DATE JLC 06/12/18 <br /> NOs�3� CHECKED M 1 b-a <br /> o <br /> BUILDING 40-58 <br /> m3,Fo , APPROVED �06 No. COMP No. 40-58-M1b-a x <br /> 9Tf OF At11 09' APPROVED DWG NO. <br /> MECHANICAL MASTER EVERETT,WA 40-58-M1b-a <br />
The URL can be used to link to this page
Your browser does not support the video tag.