My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-58 Plans 2022-11-09 (3)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-58 Plans 2022-11-09 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 10:02:42 AM
Creation date
8/5/2021 3:34:10 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
M1811-038
Year
2019
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ MECHANICAL ABBREVIATIONS AIR DISTRIBUTION LEGEND PIPING LEGEND CONTROLS LEGEND PLUMBING LEGEND <br /> ABBR DESCRIPTION ABBR DESCRIPTION ABBR DESCRIPTION SYMBOL I ABBR I DESCRIPTION SYMBOL I ABBR I DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br /> k COMPRESSED AIR FPM FEET PER MINUTE PSIG POUNDS PER SQUARE INCH GAUGE EXISTING DUCT THIN LINEWORK INDICATES EXISTING PIPING OR EQUIPMENT IA INSTRUMENT AIR PIPING <br /> >CCTWP AIR COMPRESSOR COOLING TOWER WATER PUMP FPS FEET PER SECOND PSW PROCESS SOFTENED WATER -/////////i HATCHING INDICATES PIPING OR EQUIPMENT TO BE REMOVED A 0 DIGITAL INPUT OR OUTPUT <br /> \RCH ARCHITECTURAL FS FLOW SWITCH PT PRESSURE/TEMPERATURE TAP / CA COMPRESSED AIR PIPING <br /> VDU AIR ACCESS DOOR UNIT FFT FEET TU FAN TERMINAL UNIT PW PTAC <br /> PPACKAGED ROCESS TERMINAL AIR CONDITIONER ` //A DUCT TO BE DEMOLISHED APV APV AUTOCLAVE PROCESS VACUUM A VANALOG INPUT OR OUTPUT - <br /> APW APW AUTOCLAVE PROCESS VACUUM VENT CW COLD WATER PIPING <br /> kD AUTOMATIC DAMPER FV FACE VELOCITY PV PROCESS VACUUM RECTANGULAR DUCT SIZE IN INCHES CA CA COMPRESSED AIR - PCW - PUMPED COLD WATER PIPING <br /> kF AIRFOIL + 18x12 IL FIRST SIZE LISTED IS SIDE SHOWN COMMUNICATIONS INTERFACE <br /> kFF ABOVE FINISHED FLOOR G NATURAL GAS QTY QUANTITY CTWS CTWS COOLING TOWER WATER SUPPLY O ___ HW 110°HOT WATER PIPING <br /> kFG ABOVE FINISHED GRADE GA GAUGE 18"O 8 ROUND DUCT SIZE IN INCHES CTWR CTWR COOLING TOWER WATER RETURN -1 - - HWC- - - - HOT WATER CIRCULATING PIPING <br /> kHU AIR HANDLING UNIT GAL GALLON RA RETURN AIR DRY CONTACT <br /> kL ACOUSTIC LINED GALV GALVANIZED RECIRC RECIRCULATION CHWS CHWS CHILLED WATER SUPPLY G NATURAL GAS PIPING <br /> kLT ALTERNATE GPH GALLONS PER HOUR RF RETURN FAN DOUBLEWALL CONSTRUCTION CURRENT SENSOR/TRANSMITTER <br /> kP ACCESS PANEL GPM GALLONS PER MINUTE RG RETURN AIR GRILLE CHWR CHWR CHILLED WATER RETURN <br /> CT <br /> ON COOLING UNITS IN CCA SAN SANITARY DRAINAGE PIPING (ABOVE SLAB) <br /> kPV AUTOCLAVE PROCESS VACUUM GR GREASE RAR RETURN AIR REGISTER HHWS HHWS HEATING HOT WATER SUPPLY STR STARTER <br /> \PW AUTOCLAVE PROCESS VACUUM VENT GTH GRAND TOTAL HEAT RAT RETURN AIR TEMPERATURE D - - SAN - - SANITARY DRAINAGE PIPING (UNDERGROUND) <br /> kSHRAE AMERICAN SOCIETY OF HEATING, REF REFRIGERANT DUCT OFFSET(DOWN) IN DIRECTION HHWR HHWR HEATING HOT WATER RETURN <br /> DCWS CWS CONDENSER WATER SUPPLY DUCT SMOKE DETECTOR ORWL RAINWATER LEADER-OVERFLOW <br /> REFRIGERATION,AND AIR CONDITIONING ENGINEERS H HUMIDIFIER,HUMIDISTAT RH RELATIVE HUMIDITY OF ARROW(NOT TYPICALLY SHOWN) <br /> kSME AMERICAN SOCIETY OF MECHANICAL ENGINEERS H2O WATER RHC REHEAT COIL U_ CWR CWR CONDENSER WATER RETURN RWL RAINWATER LEADER-PRIMARY <br /> kUX AUXILIARY HC HEATING COIL RHP ROOFTOP HEAT PUMP +1111{ U DUCT OFFSET(UP) IN DIRECTION OF <br /> HD HEAD RLA RATED LOAD AMPS ARROW(NOT TYPICALLY SHOWN) CHGS CHGS CHILLED GLYCOL SUPPLY F - - STS - - STORM PIPING (UNDERGROUND) <br /> 3A BREATHING AIR HDT HORIZONTAL DRAW THRU RM ROOM Jr X SUPPLY AIR DUCT SECTION FLOW METER <br /> 3AL BALANCING HDV HOLD DOWN VACUUM RPM REVOLUTION PER MINUTE CHGR CHGR CHILLED GLYCOL RETURN - - - -V- - - - VENT PIPING <br /> TURNED UP OR TOWARDS <br /> 3AS BUILDING AUTOMATION SYSTEM HWS/R HYDRONIC HEATING SUPPLY/RETURN RV ROOF VENT HWS HWS HEATING WATER SUPPLY CD CONDENSATE PIPING <br /> 3DD BACKDRAFT DAMPER HHWS/R HEATING HOT WATER SUPPLY/RETURN RWL RAIN WATER LEADERJr SUPPLY AIR DUCT SECTION HWR HWR HEATING WATER RETURN AIR TEMPERATURE SENSOR <br /> 3CU BLOWER COIL UNIT HP HORSEPOWER TURNED DOWN OR AWAY T - - - CD - - CONDENSATE PIPING (UNDERGROUND) <br /> 3HP BREAK HORSEPOWER H/P HEAT PUMP SA SUPPLY AIR LPS LPS LOW PRESSURE STEAM SUPPLY <br /> 3LDG BUILDING HPA HIGH PRESSURE COMPRESSED AIR SD SMOKE DAMPER RETURN AIR DUCT SECTION LPC LPC LOW PRESSURE STEAM CONDENSATE GR GREASE PIPING <br /> 30D BOTTOM OF DUCT HR HOUR SD SUPPLY DIFFUSER Jr / TURNED UP OR TOWARDS AIR FLOW MEASURING STATION - - - -GR- - - - GREASE PIPING (UNDERGROUND) <br /> 30P BOTTOM OF PIPE HRU HEAT RECOVERY UNIT SFD SMOKE/FIRE DAMPER MPS MPS(20) MEDIUM PRESSURE STEAM SUPPLY NUMBER IN <br /> 3TU BRITISH THERMAL UNIT PER HOUR HTG HEATING SG SUPPLY AIR GRILLE F SSD — — SUB SOIL DRAIN PIPING <br /> 3THU BRITISH THERMAL UNIT PER HOUR HVAC HEATING,VENTILATION AND AIR CONDITIONING SAN SANITARY SEWER RETURN AIR DUCT SECTION HPS HPS(200) HPS PRESSURE STEAM SUPPLY NUMBER IN <br /> • <br /> TURNED DOWN OR AWAY <br /> HX HEAT EXCHANGER SAR SUPPLY AIR REGISTER / PC PC STEAM CONDENSATE (PUMPED) IW INDUSTRIAL WASTE PIPING <br /> ;AP CAPACITY HZ HERTZ SAT SUPPLY AIR TEMPERATURE M 2-WAY CONTROL VALVE W/24V ACTUATOR <br /> EXHAUST AIR DUCT SECTION CD CD CONDENSATE DRAIN - INDIRECT UNO <br /> ;/C CENTER OF CENTER HW DOMESTIC HOT WATER SATT SOUND ATTENUATORX PIW PUMPED INDUSTRIAL WASTE PIPING <br /> 'C COOLING COIL HWC DOMESTIC HOT WATER CIRCULATING SCH SCHEDULE TURNED UP OR TOWARDS D D DRAIN- INDIRECT <br /> ;D CONDENSATE DRAIN SCHWP SECONDARY CHILLER WATER PUMP M 3-WAY CONTROL VALVE W/24V ACTUATOR <br /> ;ENTRI CENTRIFUGAL IAC INDUSTRIAL AIR COMPRESSOR SD SUPPLY DIFFUSER EXHAUST AIR DUCT SECTION PIPE WITH ARROW INDICATING FLOW DIRECTION UNO - PW - PROCESS WATER PIPING <br /> ;FM CUBIC FEET PER MINUTE IBC INTERNATIONAL BUILDING CODE SEC SECOND X TURNED DOWN OR AWAY PIPE CONTINUATION CLV CLEAN OUT VACUUM PIPING <br /> ;H CHILLER IH INFRARED HEATER SEER SEASONAL ENERGY EFFICIENCY RATIO M 2-WAY BUTTERFLY VALVE W/24V ACTUATOR <br /> ;HW CHILLED WATER IMC INTERNATIONAL MECHANICAL CODE SMACNA SHEET METAL AND AIR CONDITIONING ROUND DUCT SECTION 7 PIPE END CAP UNO <br /> q (�� HDV HOLD DOWN VACUUM PIPING <br /> :MP CHILLED WATER PUMP IN INCHES CONTRACTORS'NATIONAL ASSOCIATION t ` y TURNED UP OR TOWARDS D PIPE TURNING DOWN OR AWAY <br /> ;HWS/R CHILLED WATER SUPPLY/RETURN INFO INFORMATION SF SUPPLY FAN 0 PIPE TURNING UP OR TOWARD ® SPACE TEMPERATURE SENSOR PV PROCESS VACUUM PIPING <br /> ;I CAST IRON IPC INTERNATIONAL PLUMBING CODE SG SOFFIT GRILLE ROUND DUCT SECTION <br /> ;IRC CIRCULATING 1ST ICE STORAGE TANK SHT SHEET ( ')/ TURNED DOWN OR AWAY PIPE TURNING DOWN OR AWAY <br /> ;LG COOLING IW INDUSTRIAL WASTE SP STATIC PRESSURE v 0 SPACE RELATIVE HUMIDITY SENSOR IX GATE VALVE <br /> ;LV CLEAN UP VACUUM SPEC SPECIFICATION D CONCENTRIC REDUCER (NOT TYPICALLY SHOWN) <br /> ;OL COLUMN KW KILOWATTS SPECD SPECIFIED �I�' v ECCENTRIC REDUCER(NOT TYPICALLY SHOWN) O P SPACE STATIC PRESSURE SENSOR —� BALL VALVE <br /> ;OND CONDENSATE SQ SQUARE <br /> ;ONN CONNECTION L LOUVER SS STAINLESS STEEL + DUCT SECTIONS UP <br /> THROUGH SLAB OR ROOF X PIPE ANCHOR DPI CIRCUIT SETTER VALVE <br /> ,ONT CONTINUE LAT LEAVING AIR TEMPERATURE SS SERVICE SINK ALIGNMENT GUIDE T Ar^ <br /> ',OP COEFFICIENT OF PERFORMANCE LAV LAVATORY SSD SUB SOIL DRAIN _ _ IMMERSION TEMPERATURE TRANSMITTER V� COMBINATION BALANCING/SHUTOFF VALVE <br /> ',02 CARBON DIOXIDE LB POUND SSF SIDE STREAM FILTER f ® 41 PUMP (DIAGRAM) _ WITH THERMOWELL <br /> ',TWS/R COOLING TOWER WATER SUPPLY/RETURN LBS/HR POUNDS PER HOUR STD STANDARD �I CHECK VALVE <br /> ;U CONDENSING UNIT LDS LEAK DETECTION SENSOR STL STEEL PIPE SECTION UP Iw1 FLEXIBLE CONNECTOR PRESSURE REGULATING VALVE <br /> ;W DOMESTIC COLD WATER LO LOW STM STEAM THROUGH SLAB OR ROOF I-❑ EMERGENCY PUSHBUTTON <br /> LPG LIQUID PETROLEUM GAS STRUCT STRUCTURAL - H INDICATES ASSEMBLY OF PIPING GLOBE VALVE <br /> )B DRY BULB LRA LOCKED ROTOR AMPS STS STORM SEWER END OF DUCT WITH CAP COMPONENTS (AS NOTED OR <br /> )EG DEGREE LVR LOUVER VS VIBRATION SWITCH <br /> DIAGRAMMED) -1 El BUTTERFLY VALVE(UNLESS NOTED OTHERWISE) �4 SHUTOFF VALVE (AS SPECIFIED FOR PIPING SYSTEM) <br /> )G DOOR GRILLE LWT LEAVING WATER TEMPERATURE TBD TO BE DECIDED 1) RELIEF VALVE <br /> )H DOOR HEATER TG TRANSFER AIR GRILLE I I I I I I I I I I I FLEXIBLE DUCT 6 BV BALL VALVE FLOW MEASUREMENT STATION <br /> )L DOOR LOUVER MA MIXED AIR TAR TRANSFER AIR REGISTER CKV CHECK VALVE CO CARBON DIOXIDE SENSOR/TRANSMITTER <br /> )DC DIRECT DIGITAL CONTROL MAU MAKE-UP AIR UNIT TD TEMPERATURE DIFFERENTIAL I�I Y-TYPE STRAINER <br /> )IA DIAMETER MAX MAXIMUM TEAO TOTALLY ENCLOSED AIR OVER E AD DUCT ACCESS DOOR <br /> III <br /> L BFV BUTTERFLY VALVE <br /> )IFF DIFFERENTIAL MBH 1000 BRITISH THERMAL UNITS PER HOUR TEFC TOTALLY ENCLOSED FAN COOLED {� THERMOSTATIC MIXING VALVE <br /> )MPR DAMPER MCA MINIMUM CIRCUIT AMPACITY TEMP TEMPERATURE tk BAL VA BALANCING VALVE Co CARBON MONOXIDE SENSOR/TRANSMITTER <br /> )N DOWN MCC MOTOR CONTROL CENTER TH TOTAL HEAD " 1:C114 <br /> CONCENTRIC DUCT TRANSITION WCBAL VA CALIBRATED BALANCING VALVE L PLUG VALVE <br /> )OM DOMESTIC MECH MECHANICAL TSH TOTAL SENSIBLE HEAT " CD THERMOSTAT <br /> r� <br /> )P DIFFERENTIAL PRESSURE MEZZ MEZZANINE TSP TOTAL STATIC PRESSURE yr BSV COMBINATION BALANCING/SHUTOFF VALVE <br /> )R DRYER MFS MAXIMUM FUSE SIZE TSTAT THERMOSTAT ECCENTRIC DUCT TRANSITION ACV MODULATING CONTROL VALVE W/ACTUATOR pp DIFFERENTIAL PRESSURE I CLEANOUTS <br /> )WG DRAWING MIN MINIMUM TYP TYPICAL O <br /> )X DIRECT EXPANSION MISC MISCELLANEOUS TOD TOP OF DUCT g ACV 3-WAY MODULATING CONTROL VALVE W/ACTUATOR SENSOR/TRANSMITTER OR S--0 <br /> MOCP MAXIMUM OVER CURRENT PROTECTION TOS TOP OF STEEL SQUARE TO ROUND TRANSITION VFD VARIABLE FREQUENCY DRIVE • <br /> EA EXHAUST AIR MOP MOTOR OVERCURRENT PROTECTION p� PRV PRESSURE REDUCING VALVE ] PIPE END CAP <br /> EG EXHAUST AIR GRILLE MVD MANUAL VOLUME DAMPER UBC UNIFORM BUILDING CODE RV RELIEF VALVE <br /> EAR EXHAUST AIR REGISTER U/G UNDER GROUND MANUAL VOLUME DAMPER SP D PIPE TURNING DOWN <br /> EAT ENTERING AIR TEMPERATURE N NORTH UH UNIT HEATER MVD b FMS FLOW MEASUREMENT STATION STATIC PRESSURE SENSOR/TRANSMITTER <br /> ECO EXTERIOR CLEAN OUT NA NOT APPLICABLE UL UNDERWRITER'S LABORATORIES STR Y-TYPE STRAINER 0 PIPE TURNING UP <br /> EDH ELECTRIC DUCT HEATER NC NORMALLY CLOSED UMC UNIFORM MECHANICAL CODE LIGHT <br /> EER ENERGY EFFICIENCY RATIO N/C NOISE CRITERIA UNO UNLESS NOTED OTHERWISE BDD BACKDRAFT DAMPER pb NV NEEDLE VALVE PIPE TURNING DOWN (TEE) <br /> EF EXHAUST FAN NEC NATIONAL ELECTRIC CODE UPC UNIFORM PLUMBING CODE 011 HORN AND STROBE <br /> EFF EFFICIENCY NFPA NATIONAL FIRE PROTECTION ASSOCIATION UTIL UTILITY 7 SHC VA SQUARE HEAD COCK VALVE — <br /> EG EXHAUST GRILLE NIC NOT IN CONTRACT TWO POSITION PARALLEL BLADE I I PIPING TEE <br /> ELEC ELECTRIC,ELECTRICAL NO NORMALLY OPEN V VOLTS,VOLTAGE DAMPER WITH ACTUATOR PV PLUG VALVE DIFFERENTIAL PRESSURE INDICATING <br /> TRANSMITTER <br /> ELEV ELEVATION NOM NOMINAL V VENT 1*1 GLV GLOBE VALVE D D ROLL DOWN <br /> EMCS ENERGY MANAGEMENT CONTROL SYSTEM NPSH NET POSITIVE SUCTION HEAD VAC VACUUM MD MODULATING OPPOSED BLADE11 <br /> EQUIP EQUIPMENT NTS NOT TO SCALE VAR VARIABLE " :1117E-4DAMPER WITH ACTUATOR iXi OSY VA OUTSIDE SCREW AND YOKE VALVE 1 <br /> OPPOSED BLADE CONTROL DAMPER <br /> ES EMERGENCY SHOWER VAV VARIABLE AIR VOLUME �4 EXP VA EXPANSION VALVE i WITH 24V ACTUATOR UNO DO P-TRAP <br /> ESP EXTERNAL STATIC PRESSURE OA OUTSIDE AIR VD VOLUME DAMPER FIRE DAMPER W/ACCESS <br /> ET EXPANSION TANK OAT OUTSIDE AIR TEMPERATURE VDT VERTICAL DRAW THRU FD DOOR IN DUCT SOL VA SOLENOID VALVE (TWO-POSITION W/ACTUATOR) / FLOW ARROW <br /> EWT ENTERING WATER TEMPERATURE OAU OUTSIDE AIR UNIT VEL VELOCITY lig <br /> EX-I EXHAUST OC ON CENTER VERT VERTICAL FIRE/SMOKE DAMPER WITH PARALLEL BLADE CONTROL DAMPER <br /> FSD � HB-? OR WHY-? HOSE BIBB/WALL HYDRANT <br /> EXIST EXISTING ODP OPEN DRIP PROOF VFD VARIABLE FREQUENCY DRIVE ACCESS DOOR IN DUCT PICV PRESSURE INDEPENDENT CONTROL VALVE WITH 24V ACTUATOR UNO <br /> EXPL EXPLOSION ORWL OVERFLOW RAIN WATER LEADER VLV VALVE <br /> OSA OUTSIDE AIR VOL VOLUME SMOKE DAMPER WITH O 0 PDI-"?" WATER HAMMER ARRESTER&SIZE <br /> 'F DEGREES FAHRENHEIT VTR VENT TO ROOF SMD i AFCV AUTOMATIC FLOW CONTROL VALVE <br /> :A FACE AREA PCHWP PRIMARY CHILLED WATER PUMP VVT VARIABLE VOLUME AND TEMPERATURE ACCESS DOOR IN DUCT <br /> 'ACP FIRE ALARM CONTROL PANEL PCT PERCENT -III-- UNION <br /> o THERMOMETER <br /> :AS FIRE ALARM SYSTEM PCW PUMPED COLD WATER W WATT(S) LT LLT LOW LIMIT THERMOSTAT �� oo DUCT MOUNTED RH SENSOR I <br /> :D FLOOR DRAIN PD PRESSURE DROP W/ WITH FLANGES <br /> D FIRE DAMPER PERF PERFORATED W/O WITHOUT � INDICATES SUPPLY AIR FLOW DIRECTION A THREADED DRAIN PLUG ® PUMP-ARROW INDICATES DIRECTION OF FLOW CI) PRESSURE GAUGE <br /> :C FORWARD CURVE PF PREFILTER WB WET BULB � INDICATES RETURN OR EXHAUST AIR <br /> :CO FLOOR CLEANOUT PH PHASE WC WATER CLOSET BALANCING VALVE <br /> :CU FAN COIL UNIT PIW PUMPED INDUSTRIAL WASTE WCO WALL CLEANOUT FLOW DIRECTION 1 MALE (GARDEN) HOSE CONNECTION WITH CAP pT4 <br /> :F FINAL FILTER PLBG PLUMBING WG WATER GAGES UNDERCUT Q TP TEST PLUG ��- SPACE PUSH-BUTTON OVER RIDE SWITCHefi CIRCULATING CIRCULATING PUMP <br /> :GI FABRA HOOD GRAVITY INTAKE PLCS PLACES WH WALL HEATER <br /> :GR FABRA HOOD GRAVITY RELIEF POC POINT OF CONNECTION WSNEC WASHINGTON STATE NON-RESIDENTIAL THERMOSTAT 4 FL SW FLOW SWITCH <br /> :10 FURNISHED AND INSTALLED BY OWNER PROP PROPELLER CODE FLOW SWITCH <br /> :LD FLOOR DRAIN PRS PRESSURE REDUCING STATION VVT WEIGHT CEILING SUPPLY DIFFUSER. REFER TO I DUPLEX CA DROP <br /> :LEX FLEXIBLE PRV PRESSURE REDUCING VALVE ® DIFFUSER AND GRILLE SCHEDULE FOR PR SW PRESSURE SWITCH <br /> LG FLANGE PS PRESSURE SWITCH Y WYE ADDITIONAL INFORMATION. -I cliTHERMOMETER <br /> :LR FLOOR PSAN PUMPED SANITARY O TH THERMOMETER SIMPLEX CA DROP <br /> :OIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR ZD ZONE DAMPER LINEAR SLOT DIFFUSER. REFER TO �- <br /> , 1 DIFFUSER AND GRILLE SCHEDULE FOR 1 SAIL SWITCH <br /> GENERAL LEGEND <br /> E G r N D ADDITIONAL INFORMATION. UB STR BASKET STRAINER • <br /> V C Iv OC OCCUPANCY SENSOR VACUUM DROP <br /> SYMBOL I DESCRIPTION REVISION CLOUD AND CEILING GRILLE (RETURN OR TRANSFER) PG PRESSURE GAUGE <br /> # - 0 0 <br /> REVISION NUMBER REFER TO DIFFUSER AND GRILLE <br /> A DETAIL SYMBOL: • / SCHEDULE FOR ADDITIONAL INFORMATION AAV AUTOMATIC AIR VENT <br /> A= IDENTIFYING NUMBER POINT OF CONNECTION <br /> B B=SHEET WHERE DETAIL IS SHOWN SYMBOL I MAV MANUAL AIR VENT ` <br /> POINT OF DEMOLITION CEILING EXHAUST GRILLE. REFER TO <br /> DIFFUSER AND GRILLE SCHEDULE FOR R �'w�'�N Ac <br /> AK I SECTION SYMBOL: SYMBOL ADDITIONAL INFORMATION. M WM WATER METER I . 2 ,T,^ �'��� 0- , 7 k ::: '-' ,s,�-4 . <br /> A= IDENTIFYING NUMBER KEYED REFERENCE <br /> .„ <br /> .., k B=SHEET WHERE SECTION IS SHOWN E. NOTE OR SHEET NOTE 7 METER (AS INDICATED) ,f ,., -3 ''1 ''- i. <br /> B GRILLE REGISTER OR OPEN www,b >ront f� <br /> AILEQUIPMENT TYPE Copyr Copyright 02018 `,: ' �'� / <br /> DUCT(SUPPLY SHOWN) MAGNEHELIC DIFFERENTIAL PRESSURE GAUGE <br /> DEVICE IDENTIFICATION: (REFER TO SCHEDULES) Architects Engineers, Inc. ,��o 51476 �� �c��,; ' • <br /> SD-2 1-B/5 0A� �CISTER ;'" <br /> (REFER TO SCHEDULES) �s MULTABLE EQUIP AT COLUMN AREA STEAM TRAP 1 e s+ own .,''"�`�SIONaL E�� " . <br /> 800 CFM FLOOR LOCATED ON COLUMN LINE TOP/BOTTOM '-300 Writ g n Ar neNo.5 J2355t e':` ' .. g ri13-a° <br /> COLUMN LINE LEFT/RIGHT Eng+ee g►o.3131 Q <br /> F.fM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE W n s ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE v <br /> of sit/ JXK 06/12/18 KEY S H E ET w2548317 0 06/12/1877. <br /> P� c THIS DESIGN AND/OR CHECKED <br /> 0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 �o JLC 06/12/18 SHEET <br /> ® 5 ti SPECIFICATION IS APPROVED BO@Illg 777X CWC BUILCING <br /> eRPH aRCHiTecrs ENGINEER co <br /> TITLE <br /> r ENcweERswc. APPROVED BY DEPT. DATE JLC 06/12/18 N <br /> ® M1 a-a <br /> No3�s7 _ CHECKED <br /> `�' o APPROVED <br /> BUILDING 40-58 `� <br /> \ JOB NO. COMP NO. 40-58-M1a-a <br /> FC47F OF auiHC)°1- APPROVED MECHANICAL MASTER EVERETT,WA DWG No. 40-58-M1a-a <br />
The URL can be used to link to this page
Your browser does not support the video tag.