(TYPICAL OF 6) EF-43,44,45,46,47,48 <br /> T <br /> GAS <br /> OA i HEATER C:31 SA EA <br /> FOR VFD VFD 1 ® 0 EMCS <br /> CONNECTION W VFD <br /> © I NO SEE ELECTRICAL FOR TYPICAL VFD <br /> SHEETS CONNECTION SEE <br /> z ELECTRICAL SHEETS <br /> O o Q a a l <br /> COLO CD O w <br /> id cc <br /> a a w > <br /> V O C.) CO <br /> O <br /> o 0 > 0 CO � CO CO Cr) <br /> VA VA AV o o <br /> EMCS EMCS EMCS EMCS EMCS EMCS EMCS EMCS EMCS <br /> (TYPICAL OF 3) <br /> MAKEUP AIR UNIT <br /> MAU-01, 02, 03 <br /> AUTOCLAVE PIT VENTILATION SYSTEM <br /> MAKEUP AIR UNIT NORMAL OPERATION: <br /> SYSTEM DESCRIPTION: THREE MAKE-UP AIR UNITS, EACH COMPRISED OF AN OUTSIDE AIR PATH WITH OUTSIDE AIR DAMPER, FILTERS (MERV <br /> 13), DIRECT FIRED GAS HEATER, VARIABLE SPEED SUPPLY FAN, AND ALL ASSOCIATED APPURTENANCES AND DEVICES DEPICTED ON THE <br /> CONTROL SYSTEM DIAGRAM. THE EXHAUST FAN SYSTEM IS COMPRISED OF(6)VARIABLE VOLUME EXHAUST FANS WITH VFDS, ONE OF WHICH <br /> IS FUTURE, AND ALL ASSOCIATED APPURTENANCES AND DEVICES DEPICTED ON THE CONTROL SYSTEM DIAGRAM. <br /> GENERAL: THE SYSTEM SHALL BE AVAILABLE FOR OPERATION AT ALL TIMES DEFINED BELOW TO MAINTAIN SPECIFIC SPACE PARAMETERS. <br /> OTHERWISE, THE SYSTEM SHALL BE IN UNOCCUPIED MODE. ALL CONTROLS SHALL BE AUTOMATIC. <br /> DEFINED OCCUPIED PERIOD: MON-FRI: 4:OOAM-11:OOPM AND SAT-SUN: 5:OOAM-5:OOPM <br /> MAINTENANCE: WHEN THE MAU SUPPLY FAN IS OFF FOR MAINTENANCE, RESPECTIVE CONTROL DEVICES SHALL BE POSITIONED AS <br /> FOLLOWS: <br /> 1. CONTROL VALVES POSITIONED CLOSED. <br /> 2. OUTDOOR AIR DAMPER POSITIONED CLOSED. <br /> SYSTEM START/STOP: THE UNITS SHALL BE STARTED/STOPPED BY THE EMCS ACCORDING TO THE SPACE TEMPERATURE SETPOINT AND THE <br /> CURRENT MODE. <br /> UNOCCUPIED MODE: THE SYSTEM SHALL REMAIN IN UNOCCUPIED MODE UNLESS THE SPACE PUSH BUTTON STYLE OCCUPANCY SWITCH IS <br /> PLACED IN THE OCCUPIED POSITION, WHICH SHALL PLACE THE SYSTEM IN OCCUPIED MODE FOR A PERIOD OF 90 MINUTES.AFTER 90 <br /> MINUTES, THE SYSTEM SHALL AUTOMATICALLY RETURN TO UNOCCUPIED MODE. THE SYSTEM SHALL BE DISABLED NORMALLY.ALL DEVICES <br /> SHALL BE THEIR RESPECTIVE OFF POSITION. THE UNITS SHALL OPERATE IN UNOCCUPIED HEATING AND COOLING MODES AS DESCRIBED <br /> BELOW. <br /> UNOCCUPIED HEATING:IF THE AVERAGE SPACE TEMPERATURE FALLS BELOW SETPOINT OF 62°F (ADJ.), THE LEAD MAU SHALL BE <br /> COMMANDED ON AFTER THE OUTSIDE AIR DAMPER IS CONFIRMED TO BE OPEN. THE SUPPLY FAN SHALL BE RUN AT 100% (ADJ.) SPEED <br /> (DETERMINED BY TAB CONTRACTOR). THE GAS VALVE SHALL BE OPENED AT 100%AFTER A 2 MIN (ADJ.)TIME DELAY. UNIT SHALL RUN UNTIL <br /> THE SPACE TEMPERATURE RISES ABOVE 65°F (ADJ.). <br /> THE EXHAUST FANS ASSOCIATED WITH THE MAU SHALL BE RUN AT FULL SPEED(DETERMINED BY TAB CONTRACTOR). THE LAG MAU'S SHALL <br /> BE ADDED IF SPACE TEMPERATURE REMAINS BELOW THE SETPOINT FOR ADDITIONAL 15 MIN (ADJ.). EACH MAU SHALL RUN A MINIMUM OF 15 <br /> MINUTES OR UNTIL THE TEMPERATURE SETPOINT IS SATISFIED, WHICHEVER IS GREATER. <br /> UNOCCUPIED VENTILATION: 1F THE AVERAGE SPACE AIR TEMPERATURE RISES ABOVE SETPOINT OF 78°F (ADJ.)AND OUTSIDE AIR TEMP,IS <br /> BELOW 70°F (ADJ.)AND ABOVE 50°F (ADJ.), ONE MAU &TWO EXHAUST FANS ASSOCIATED WITH THE MAU SHALL RUN AT PRESET CONSTANT <br /> SPEED CORRESPONDING TO 24,000 CFM (DETERMINED BY TAB CONTRACTOR). EACH UNIT SHALL RUN A MINIMUM OF 15 MINUTES OR UNTIL <br /> THE TEMPERATURE SETPOINT IS SATISFIED, WHICHEVER IS GREATER. <br /> AUTOCLAVE CYCLE MODE: IF THE EMCS RECEIVES A SIGNAL FROM THE AUTOCLAVE SUPPORT SYSTEM PLC, ONE MAKEUP AIR UNIT AND ONE <br /> EXHAUST FAN SHALL BE STARTED PER AUTOCLAVE CYCLE. THE MAU FAN SHALL BE COMMANDED TO ITS MINIMUM SPEED OF ' <br /> CORRESPONDING TO 24,000 CFM. THE EXHAUST FAN SHALL MODULATE TO MAINTAIN A POSITIVE PRESSURE OF 0.025 IN W.G. (ADJ.) IN THE <br /> AUTOCLAVE AREA WITH RESPECT TO THE EXTERIOR. WHEN THE EXHAUST FAN REACHES ITS MINIMUM SPEED, THE MAU FAN SPEED SHALL <br /> MODULATE UPWARD TO MAINTAIN A POSITIVE PRESSURE OF 0.025 IN W.G. (ADJ.)THE GAS VALVE SHALL ENERGIZE AS NECESSARY BASED ON <br /> THE HEATING MODE DESCRIPTION. <br /> HEATING MODE: IF THE SPACE TEMPERATURE,AS MEASURED BY THE SPACE TEMPERATURE SENSORS(AVERAGE OF ALL THREE), IS BELOW <br /> HEATING SETPOINT OF 65°F FOR MORE THAN 5 MINUTES, THE UNIT SHALL BE STARTED AND PLACED IN HEATING MODE. IF THE SPACE <br /> TEMPERATURE IS 2°F ABOVE THE HEATING SETPOINT FOR MORE THAN 5 MINUTES, THE UNIT SHALL BE STOPPED. IF THE SPACE ., • <br /> TEMPERATURE IS BELOW THE HEATING SETPOINT FOR A PERIOD OF 10 MINUTES (ADJ.), THE FIRST LAG MAU SHALL BE ENABLED. IF THE <br /> SPACE TEMPERATURE IS BELOW THE HEATING SETPOINT FOR AN ADDITIONAL 20 MINUTES (ADJ.), THE NEXT LAG MAU SHALL BE ENABLED. <br /> IF THE SPACE TEMPERATURE IS 2°F (ADJ.)ABOVE THE HEATING SETPOINT, THE FIRST LAG MAU SHALL BE DISABLED. IF THE SPACE <br /> TEMPERATURE IS STILL 2°F (ADJ.)ABOVE THE HEATING SETPOINT FOR AN ADDITIONAL 10 MINUTES (ADJ.), THE NEXT LAG MAU SHALL BE <br /> DISABLED. IF THE SPACE TEMPERATURE IS 2°F(ADJ.)ABOVE THE HEATING SETPOINT FOR AN ADDITIONAL 10 MINUTES (ADJ.), THE LEAD MAU • <br /> SHALL BE DISABLED. <br /> COOLING MODE: IF THE SPACE TEMPERATURE,AS MEASURED BY THE SPACE TEMPERATURE SENSORS (AVERAGE OF ALL THREE) IS ABOVE <br /> COOLING SETPOINT OF 80°F FOR MORE THAN 5 MINUTES, ONE EXHAUST FAN SHALL BE STARTED AND MODULATED TO MAINTAIN ROOM <br /> TEMPERATURE SETPOINT, INITIALLY SET AT 80°F. EXHAUST FANS SHALL CONTINUE TO BE ADDED AND RAMPED UP/DOWN SIMULTANEOUSLY IF <br /> THE SPACE TEMPERATURE REMAINS ABOVE COOLING SETPOINT OF 80°F FOR AN ADDITIONAL 15 MINUTES. IF THE SPACE TEMPERATURE IS <br /> BELOW COOLING SETPOINT OF 80°F FOR MORE THAN 5 MINUTES, ONE EXHAUST FAN SHALL BE SUBTRACTED FROM THE OPERATION. <br /> EXHAUST FANS SHALL CONTINUE TO BE SUBTRACTED IF THE AVERAGE SPACE TEMPERATURE REMAINS 5°F BELOW COOLING SETPOINT OF <br /> 75°F FOR 15 MINUTES. TWO EXHAUST FANS SHALL OPERATE FOR EVERY MAKEUP AIR UNIT AND SET ONE MAU TO A PRESET CONSTANT <br /> SPEED CORRESPONDING TO 24,000 CFM (ADJ.) (DETERMINED BY THE TAB CONTRACTOR), AND TWO EFS TO A PRESET CONSTANT SPEED <br /> CORRESPONDING TO 12,000 CFM (ADJ.) (DETERMINED BY THE TAB CONTRACTOR). <br /> • <br /> SUPPLY FAN CONTROL: THE EMCS SHALL START/STOP EXHAUST AND MAU FANS BASED ON SYSTEM START/STOP. SUPPLY FAN SHALL NOT BE <br /> STARTED UNTIL THE OUTSIDE AIR DAMPER HAS BEEN FULLY OPENED. IF THE SUPPLY FAN FAILS TO START/STOP BASED ON SYSTEM <br /> OPERATION, AS INDICATED BY CURRENT SENSOR,AN ALARM SHALL BE SENT AND DISPLAYED AT THE EMCS. <br /> HEATING: THE EMCS CONTROLLER SHALL MODULATE THE DIRECT FIRED GAS HEATER BY MODULATING THE GAS HEATING CONTROL VALVE TO <br /> MAINTAIN THE SPACE TEMPERATURE SETPOINT, INITIALLY SET AT 65°F, AS MEASURED BY THE SPACE TEMPERATURE SENSOR. THE EMCS <br /> CONTROLLER SHALL MODULATE THE GAS HEATING CONTROL VALVE VIA A 2-10 VDC SIGNAL. <br /> OUTSIDE AIR DAMPER CONTROL: THE OUTSIDE AIR DAMPER SHALL BE FULLY OPENED WHEN THE SYSTEM IS STARTED AND FULLY CLOSED <br /> WHEN THE SYSTEM IS STOPPED. DAMPER POSITION SHALL BE PROVED BY END SWITCH INTERNAL TO DAMPER ACTUATOR. <br /> EXHAUST FAN OPERATION: EXHAUST FANS SHALL BE STARTED/STOPPED ACCORDING TO THE CURRENT MODE IN CONJUNCTION WITH THE <br /> MAKEUP AIR UNITS. EXHAUST FANS SHALL BE STARTED AFTER A 15 SECOND TIME DELAY.IF ANY EXHAUST FAN FAILS TO START/STOP BASED <br /> ON SYSTEM OPERATION, AS INDICATED BY CURRENT SENSOR, AN ALARM SHALL BE SENT AND DISPLAYED AT THE EMCS. THE NEXT EXHAUST <br /> FAN, BASED ON RUN HOURS SHALL BE STARTED. <br /> LEAD/LAG ROTATION: LAG EQUIPMENT SHALL BE ROTATED DAILY. <br /> PROVIDE CONTINUOUS MONITORING OF THE FOLLOWING POINTS AND DISPLAY AT THE EMCS: <br /> 1. OUTSIDE AIR DAMPER POSITION <br /> 2. SPACE TEMPERATURE(°F) <br /> 3. HEATING CONTROL VALVE POSITION <br /> 4. SUPPLY FAN STATUS <br /> 5. DISCHARGE TEMPERATURE • <br /> LOW OXYGEN EXHAUST PURGE MODE: ON A SIGNAL FROM THE AUTOCLAVE SUPPORT SYSTEM PLC THAT A LOW OXYGEN CONDITION EXISTS, 4; <br /> THREE MAU'S AND FIVE EXHAUST FANS SHALL BE COMMANDED ON AFTER ALL OA DAMPERS ARE CONFIRMED TO BE IN THE OPEN POSITION. . ���NG CO�, .' <br /> THE MAU FANS SHALL BE COMMANDED TO A PRESET CONSTANT SPEED (DETERMINED BY TAB CONTRACTOR)CORRESPONDING TO 16,200 ' WAS • <br /> CFM EACH WHILE ALL THREE EXHAUST FANS SHALL BE COMMANDED TO A FULL AND CONSTANT PRESET SPEED CORRESPONDING TO 18,000 ` of <br /> CFM EACH. IF THE OA TEMPERATURE IS BELOW 35°F(ADJ.), THE GAS VALVE SHALL BE FULLY OPENED TO PROVIDE HEATING. THE LOW W � I: , o .R <br /> OXYGEN EXHAUST PURGE MODE SHALL REMAIN ACTIVE UNTIL THE LOW OXYGEN SIGNAL IS RELEASED FROM THE AUTOCLAVE SUPPORT °�' <br /> SYSTEM PLC INDICATING THAT THE OXYGEN LEVEL IS MET. �`� r �� <br /> www.brph.xom Copyright 0 2018dr.: <br /> Architects Engineers, Inc. r' • ��o� 4,,51 TER, <br /> •1020 3341,teW.See, Cotriorie of Star Amu sen SIO E�G� <br /> -BZt-3500 Na 3t 12 s t• irtg <br /> cNi <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> S rM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE wA s ACCEPTABILITY <br /> of N JXK 06112/18 W2548317 06/12/18 <br /> NET THIS DESIGN AND/OR CHECKED AUTOCLAVE PIT VENTILATION CONTROLS 0 <br /> 0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 gs a JEW 06/12/18 SHEET <br /> 5 �� SPECIFICATION IS APPROVED � <br /> ® BRPH ARCHITECTS ENGINEER TITLE Boeing777X CWC BUILDING <br /> ENGINEERS INC. APPROVED BY DEPT. DATE JLC 06/12/18 N <br /> M324a V <br /> if� CHECKED <br /> c, <br /> N0.3137 <br /> BUILDING 40-58 <br /> APPROVED JOB NO. COMP NO. <br /> \\ // 40-58-M324a <br /> oglF OF AU�NO�\�P APPROVED DWG N0. <br /> MECHANICAL MASTER EVERETT,WA 40-58-M324a <br />