My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2817 COLBY AVE FIRST INTERSTATE BANK 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
2817
>
FIRST INTERSTATE BANK
>
2817 COLBY AVE FIRST INTERSTATE BANK 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 9:56:50 AM
Creation date
8/12/2021 10:26:44 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2817
Tenant Name
FIRST INTERSTATE BANK
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12491 <br />Page 2 <br />5. Remove the item(s) obstructing proper operation of the fire protection <br />equipment. <br />a. maintain storage 18" below sprinklers <br />6. Provide and install frangible covers on the sprinkler system pumper <br />connection(s). <br />a. at front of building <br />7. Combustible waste or rubbish must be removed from the area once every <br />other day or said rubbish must be maintained in approved covered metal <br />containers or bins. <br />a. fourth floor storage area <br />b. telephone room <br />8. Install a closing device on the fire doors) and adjust same so that the <br />door(s) will close completely when released. <br />a. boiler room <br />9. Provide state certification for boiler. <br />10. Under Permit from the City of Everett Electrical Department (259-8800), <br />reinstall the electrical fixture(s) in accordance with the Electrical <br />Code. <br />a, extension cord to sump pump in boiler room <br />b. extension cord to fluorescent lighting and open wires in basement <br />C. at work bench <br />d. in telephone room <br />e. third floor computer room closet <br />11. Install approved covers on the open electrical service panel(s), junction <br />box(es), outlet(s) or switch(es). <br />a. electrical outlet at east wall of fourth floor lobby <br />b. open wires at mid -ceiling of fourth floor south room <br />c. junction boxes in basement storage area <br />d. service panel cover in telephone room <br />e. cover plate in Commercial Banking on first floor <br />12. All control, drain, test and alarm valves on the automatic sprinkler <br />system must be provided with identification signs of standard design or <br />their equivalent. <br />a. second floor system <br />
The URL can be used to link to this page
Your browser does not support the video tag.