My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2828 COLBY AVE CASCADE BANK 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
2828
>
CASCADE BANK
>
2828 COLBY AVE CASCADE BANK 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 10:17:32 AM
Creation date
8/12/2021 11:09:36 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2828
Tenant Name
CASCADE BANK
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IIII. .... ; . <br />r <br />GENERAL PLAN CORRECTION LIST <br />Based on 1973 Edition of the Uniform Building Code <br />fA,t;,,. - <br />Owner ...... Plan Check No.li::_4:? A..Valuation <br />Job F 3dress ... ........ ---------------- Use ... Q.F..f7.u-Ez.... Es:. 1.!rl.i:................... ..... <br />Date_..,J.aYL....»........ _..__... Type of Occupancy . <br />........................ »_........_.....:......_............... Construction ...»..........Classi(ication...F.-.3,......... <br />Total Allowable Floor Area ............................... Sq. Ft. Fire Zone No. ...... 1._......-Stories ....... i .................... <br />Basis for Increase Floor Area: (Ao01T`3t"1/j- Fwu2� <br />-...._................ _............ ... ........ ...................... Floor (Max.) ._.._ ...................... ....................... Sq. Ft. <br />_.._.._ ....................................... _............................. Floor (Total)..............n,6.F.0.......................... Sq. Ft. <br />_ .... _...... ................................................................... ... Occupant Load .................. `.i.1.................... .......... ...... <br />COMMENTS OR ASSUMPTIONS: <br />Corrections checked below are to be made on plane before permit is issued. <br />The approval of plans and specif cations does not permit the violation of any section of the Building Code, or other City Ordinance or <br />State Law. <br />GENERAL <br />1. <br />Valuation should be $ ........................................ <br />2. <br />Show job address on plans. <br />3.' <br />Give name of person responsible for plans. <br />4. <br />Submit fully dimensioned Plot plan. <br />5.- <br />Give all dimensions on plot plan. <br />AREA LIMITATIONS A14D GENERAL <br />OCCUPA14CY REQUIREMENTS <br />G. <br />Ground elevations slrouid be shown at corners <br />of the building and at changes in rround slope. <br />The ground elevations should be taken at the <br />lowest point between the exterior wall and a <br />point 5 feet out or at the property line, if <br />closer. Where the exterior wall is parolle! to and <br />within 5 feet of a public sidewalk, alley, or <br />other public way, the ground elevation: should <br />he the elevation of the public way. The number <br />of stories in this building cannot be determined <br />until this data is fu.nislied. <br />7:' <br />The total floor area %s limited to ........................ <br />square feet. Sections 505 and 506. <br />S. <br />Unobstrurted yards of .................... feet should <br />be maintained on .................................... sides <br />of the building for area purposes. Section 506. <br />9. <br />Provide details to show that .............................. <br />-hour area separation walls should comply with <br />Section 505 (c), <br />(a) Extend vertically from the foundation to a <br />point 30 inches above the roof. <br />(b) Trdal width of all openmgs misted to 25 per. <br />cent of the wall length fit tl•e story under <br />consideration. <br />(c) All openings protected with fire assemblies <br />having a fire -resistive rating of one -and -one. <br />half (three) hours. <br />(d) Ducts through area separation walls should <br />be avoided. If allowed, fire dampers on each <br />side of the wall are required. Section <br />30.102, U.O.C. Standards. <br />10. ` A fire -resistive occupancy separation in conform• <br />ante with Table No. 5-B and Section 503 is <br />required between the <br />....._.__:..».......» ...... ........... (...........: hours) <br />........................... _...... _........... (..._......: hours) <br />, <br />-'..................................._......... I............: hours) <br />1311-lorizontal occupancy separations should be sup. <br />ported with a structural system having equiva• <br />lent fire resistive protection. Section 503 (b). <br />12. 1The building is limited to ........................ stories <br />(.................. feet in height) as a Type.............. <br />structure. Section 507 and Table No. 5-D. <br />13. A room in which a water closet is located should <br />be separated from food preparation or storage <br />rooms by a tightfitting door. <br />TYPE OF CONSTRUCTION ' <br />14.' Type V (III-N) (IV•N) buildings are not permitted <br />in Fire Zone No. 1. Section 1602 (a). <br />15. Roof coverinCs should be fire retardant. Section <br />1G03 (n) or 1704. Details or specdicalions <br />complying with Section 3203 (0) are required. <br />ro,m 2N3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.