My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2828 COLBY AVE CASCADE BANK 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
2828
>
CASCADE BANK
>
2828 COLBY AVE CASCADE BANK 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 10:17:32 AM
Creation date
8/12/2021 11:09:36 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2828
Tenant Name
CASCADE BANK
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16. <br />Exterior (court) walls within ........ _.......... feet of <br />lines should be of ............... .hour construction. <br />Section .................... 03 (a). <br />17. ' <br />Openings in exterior (court) walls within ............ <br />feet of property lines should be protected with, <br />three -fourths -hour fire assemblies. Section <br />. <br />.................... 03 (b). _ <br />16. <br />Usable space under the first floor except n <br />Group I (J) Occupancies should be enclosed <br />as required in Section 1703. <br />19.' <br />Fire -resistive construction for structural frame <br />elements in the exterior wails should comply <br />with Footnote No. 1of Table No. 17-A and <br />Section ......................See Section 1702 for <br />clarification. <br />20. <br />Building paper should be applied to exterior <br />walls as specified in Section 1707 (a). <br />21. <br />Enclosures for floor openings should comply <br />with Table No. 17-A, Section 1706. Details <br />should clearly indicate this. <br />22. <br />Structural members carrying masonry or con. <br />crete walls in buildings over one story in height <br />should be protected with minimum one -hour <br />fire protection. Section 1708. <br />23.' <br />Nonabsorbent finish and backing for toilet room <br />walls and floor should conform with Section <br />1711 (a). <br />24.` <br />Shower stall walls should be finished with a <br />hard, nonabsorbent surface to a height of 6 <br />feet. Section 1711 (b). <br />25. <br />Doors and panels of shower and bathtub en- <br />closure should comply with Section 1711 (e) <br />Ito <br />(0, <br />26. <br />Parapet walls not less than ................ Inches in <br />height are required. Section 1709. <br />21. <br />Eave overhangs and similar architectural pro. <br />jections should comply with Section 2710. <br />28. <br />Projections beyond the exterior wall should con- <br />form with the least restrictive of the following: <br />(a) A point one-third the distance to the proper- <br />ty line from an exterior wall. Section 504 <br />(b), <br />(b) A point one-third the distance from an as. <br />sumed vertical plane located where fire - <br />resistive protection of openings is first re- <br />quired due to location of property. Section <br />504 (b). <br />29. <br />Envelope ceilings should satisfy lire following <br />t.ruldions (Section 4304 (b) 6.1: <br />(a) Should not be used to provide fire protec. <br />lion beam and girders supporting more than <br />one floor. <br />(b) Columns should be individually lire pro. <br />tected. <br />(c) Duct and outlet openings are limited to 100 <br />square inches in each 100 square feet of <br />ceiling area and should be protected with <br />approved fire dampers. <br />(d) Electrical outlet boxes shvo!d be of steel <br />and not greater than 16 square inches in <br />area. <br />30. <br />Gypsum board ceilings in conjunction with fire. <br />resistive assemblies should be supported at <br />intervals not exceeding 16 inches. Item 27, <br />Table No. 43-C. <br />31. <br />Wood stripping or suspended wood systems for <br />gypsum board ceilings should he not less than <br />2-inch nominal thickness. Section 4704 (b). . <br />(Section 4703 (b) for wall stripping ) <br />32. <br />Final partition layouts and details should be sub. <br />mitted prior to installation to ,ustily compli- <br />ance with occupancy, fire -resistive, structural, <br />and exit requirements. <br />33. <br />Justifying test data in conformance with Section <br />106 or an IC80 research recomrvendalion is <br />/required for ......................... ............ .......... _... .., <br />34. <br />Rooms in which rubbish (linen) chutes terminate <br />should be separated from the remairder of the <br />building with a one -hour occupancy separation. <br />Section 1706 (c). <br />35: <br />Openings into rubbish and linen chules should <br />not be located in required exit corridors or <br />stairways. Section 1706 (c). <br />SPECIAL OCCUPANCY REQUIREMENTS <br />Group 13 <br />36. <br />B-3 Occupancies should be of one -hour fire - <br />resistive construction if located in a basement <br />or above.the first story. Section 702 (b). <br />37. <br />B-2 Occupancies with an occupant load of 1000 <br />or more should be in Type I, 11, III one hour, III <br />Heavy Timber or IV one -hour buildings. The <br />assembly room should not be in a basement <br />If It contains this high occupant load. Section <br />702 (b). <br />38. <br />The main entrance should front directly upon or <br />have'a Moot wide access to a public way at <br />least 20 feet in width. Section 703. <br />39. <br />Light and ventilation should comply with Sectior <br />705. <br />40. <br />A One -flour Fire -Resistive Occupancy Separation <br />Is required between the boiler or central heat. <br />Ing plant and the rest of the building. Section <br />708. <br />41. <br />Exterior openings for rooms containing a boiler <br />or central healing plant should be protected <br />with three -fourths -hour fire -resistive assemblies <br />that are fixed, automatic, or self -closing if lo- <br />cated below openings in another story or if less <br />than 10 feel from other doors or windows In <br />the same building. Section 708. <br />Group C <br />42. <br />Atmospheric separations should comply with <br />Section 802 (b). <br />' <br />43. <br />Use of rooms should be clarified. Note that <br />rooms in Divisions 1 and 2 Occupancies used <br />for day care purposes and rooms used for <br />kindergarten, first, er second grade pupils and <br />Division 3 occupancies cannot he located <br />above the first story. Section 802 (c). <br />44. <br />Special hazard rooms should be separated from <br />other portions of the building by not less than <br />a One -Hour Fire -Resistive Occupancy separa- <br />tion. Section 802 (it). <br />45. <br />One required exit shnuld front directly upon, or <br />have a 20 toot wide access to, a public way at <br />least 20 feet in width. Section 803 (a). <br />46. <br />Sanitary facilities should be provided in accord. <br />ance with Section 805. <br />47, <br />1 igbl and ventilation should comply with Section <br />805. <br />
The URL can be used to link to this page
Your browser does not support the video tag.