Laserfiche WebLink
16. <br />Exterior (court) walls within ........ _.......... feet of <br />lines should be of ............... .hour construction. <br />Section .................... 03 (a). <br />17. ' <br />Openings in exterior (court) walls within ............ <br />feet of property lines should be protected with, <br />three -fourths -hour fire assemblies. Section <br />. <br />.................... 03 (b). _ <br />16. <br />Usable space under the first floor except n <br />Group I (J) Occupancies should be enclosed <br />as required in Section 1703. <br />19.' <br />Fire -resistive construction for structural frame <br />elements in the exterior wails should comply <br />with Footnote No. 1of Table No. 17-A and <br />Section ......................See Section 1702 for <br />clarification. <br />20. <br />Building paper should be applied to exterior <br />walls as specified in Section 1707 (a). <br />21. <br />Enclosures for floor openings should comply <br />with Table No. 17-A, Section 1706. Details <br />should clearly indicate this. <br />22. <br />Structural members carrying masonry or con. <br />crete walls in buildings over one story in height <br />should be protected with minimum one -hour <br />fire protection. Section 1708. <br />23.' <br />Nonabsorbent finish and backing for toilet room <br />walls and floor should conform with Section <br />1711 (a). <br />24.` <br />Shower stall walls should be finished with a <br />hard, nonabsorbent surface to a height of 6 <br />feet. Section 1711 (b). <br />25. <br />Doors and panels of shower and bathtub en- <br />closure should comply with Section 1711 (e) <br />Ito <br />(0, <br />26. <br />Parapet walls not less than ................ Inches in <br />height are required. Section 1709. <br />21. <br />Eave overhangs and similar architectural pro. <br />jections should comply with Section 2710. <br />28. <br />Projections beyond the exterior wall should con- <br />form with the least restrictive of the following: <br />(a) A point one-third the distance to the proper- <br />ty line from an exterior wall. Section 504 <br />(b), <br />(b) A point one-third the distance from an as. <br />sumed vertical plane located where fire - <br />resistive protection of openings is first re- <br />quired due to location of property. Section <br />504 (b). <br />29. <br />Envelope ceilings should satisfy lire following <br />t.ruldions (Section 4304 (b) 6.1: <br />(a) Should not be used to provide fire protec. <br />lion beam and girders supporting more than <br />one floor. <br />(b) Columns should be individually lire pro. <br />tected. <br />(c) Duct and outlet openings are limited to 100 <br />square inches in each 100 square feet of <br />ceiling area and should be protected with <br />approved fire dampers. <br />(d) Electrical outlet boxes shvo!d be of steel <br />and not greater than 16 square inches in <br />area. <br />30. <br />Gypsum board ceilings in conjunction with fire. <br />resistive assemblies should be supported at <br />intervals not exceeding 16 inches. Item 27, <br />Table No. 43-C. <br />31. <br />Wood stripping or suspended wood systems for <br />gypsum board ceilings should he not less than <br />2-inch nominal thickness. Section 4704 (b). . <br />(Section 4703 (b) for wall stripping ) <br />32. <br />Final partition layouts and details should be sub. <br />mitted prior to installation to ,ustily compli- <br />ance with occupancy, fire -resistive, structural, <br />and exit requirements. <br />33. <br />Justifying test data in conformance with Section <br />106 or an IC80 research recomrvendalion is <br />/required for ......................... ............ .......... _... .., <br />34. <br />Rooms in which rubbish (linen) chutes terminate <br />should be separated from the remairder of the <br />building with a one -hour occupancy separation. <br />Section 1706 (c). <br />35: <br />Openings into rubbish and linen chules should <br />not be located in required exit corridors or <br />stairways. Section 1706 (c). <br />SPECIAL OCCUPANCY REQUIREMENTS <br />Group 13 <br />36. <br />B-3 Occupancies should be of one -hour fire - <br />resistive construction if located in a basement <br />or above.the first story. Section 702 (b). <br />37. <br />B-2 Occupancies with an occupant load of 1000 <br />or more should be in Type I, 11, III one hour, III <br />Heavy Timber or IV one -hour buildings. The <br />assembly room should not be in a basement <br />If It contains this high occupant load. Section <br />702 (b). <br />38. <br />The main entrance should front directly upon or <br />have'a Moot wide access to a public way at <br />least 20 feet in width. Section 703. <br />39. <br />Light and ventilation should comply with Sectior <br />705. <br />40. <br />A One -flour Fire -Resistive Occupancy Separation <br />Is required between the boiler or central heat. <br />Ing plant and the rest of the building. Section <br />708. <br />41. <br />Exterior openings for rooms containing a boiler <br />or central healing plant should be protected <br />with three -fourths -hour fire -resistive assemblies <br />that are fixed, automatic, or self -closing if lo- <br />cated below openings in another story or if less <br />than 10 feel from other doors or windows In <br />the same building. Section 708. <br />Group C <br />42. <br />Atmospheric separations should comply with <br />Section 802 (b). <br />' <br />43. <br />Use of rooms should be clarified. Note that <br />rooms in Divisions 1 and 2 Occupancies used <br />for day care purposes and rooms used for <br />kindergarten, first, er second grade pupils and <br />Division 3 occupancies cannot he located <br />above the first story. Section 802 (c). <br />44. <br />Special hazard rooms should be separated from <br />other portions of the building by not less than <br />a One -Hour Fire -Resistive Occupancy separa- <br />tion. Section 802 (it). <br />45. <br />One required exit shnuld front directly upon, or <br />have a 20 toot wide access to, a public way at <br />least 20 feet in width. Section 803 (a). <br />46. <br />Sanitary facilities should be provided in accord. <br />ance with Section 805. <br />47, <br />1 igbl and ventilation should comply with Section <br />805. <br />