My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2828 COLBY AVE CASCADE BANK 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
2828
>
CASCADE BANK
>
2828 COLBY AVE CASCADE BANK 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 10:17:32 AM
Creation date
8/12/2021 11:09:36 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2828
Tenant Name
CASCADE BANK
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l <br />120` <br />When three or more exits are required, no more <br />than two required exits should exit into the <br />same exit syslvm. Section 3317 (h). <br />121 <br />No point in a room in a building should he more <br />than 75 feel to an exit corridor, enclosed "air- <br />way or exterior of the building. Section 3317' <br />t). <br />122. <br />Exiling through adjoining rooms should comply <br />. with Section 3317 (d). <br />123. <br />Panic hardware is required on exit doors serving <br />rooms containing more than 100 occupants <br />and in corridors of Group C Occupancies. See. <br />tion 3317 (1). <br />1241 <br />Every room in a Group D Occupancy should have <br />access to at least two legal mean; of egress. <br />action 3318 (a). <br />125.1 <br />Doors from bedrooms and wards of Group D <br />Occupancies and all exit openings where non. <br />ambulatory patients are housed should have a <br />minimum clear width of 44 inches. No pro. <br />jections in this width are allowed. Section 3318 <br />(b). <br />126. <br />Panic hardware is required on exit doors serving <br />more than 50 occupants in Group D Occupan. <br />cies unless there is no latch or lock. Section <br />3318 (f). <br />rLOOR, ROOF CONSTRUCTION, COVERING, . <br />SKYLIGHTS, ROOF STRUCTURFS <br />127. <br />The space between wood floor construction and <br />a suspended ceiling below should be divided <br />Into areas not exceeding 1000 square feel. <br />Section 2517 (e). <br />1213. <br />{ Attics of combustible material should ti • divided <br />into areas not exceeding 3000 (9000) square <br />feet. Section 3205 (b). <br />129. <br />Roof drainage should be conducted under the <br />public sidewalk. Section 3207 (e). <br />130. <br />Overflow drains having the same size as roof <br />drains and on independent drain lines are re- <br />quired. In lieu of this, overflow scuppers Ihr_c <br />times the size of roof drains should be installed <br />In parapet wills. Overflow system should have <br />inlets located 2 inches above the low points <br />f the roof. Section 3207 (c). <br />131. <br />The aggregate area of penthouses and other roof <br />structures cannot exceed 331/s percent of the <br />supporting roof area. Section 3601 (b). <br />FIRE -EXTINGUISHING SYSTEM <br />132. <br />An approved automatic tire -extinguishing system <br />in the ............................................ is required. <br />Section 3802 (b). This includes blind spaces <br />enclosed wholly at patily by combustible con. <br />struction. <br />1?3. <br />Dry standpipes are required in buildings four or <br />more stories in height. Section 3803. <br />134. <br />Wet standpipes are required as specified in Sec- <br />tion 3804. <br />135. <br />CoAtbination standpipes are required in build. <br />ings exeeding 150 feel In height. Section 3805 <br />136.1 <br />Buildings six stories or more in height should be <br />Provided with not less than one standpipe dur. <br />hip. construction. Section 380G (b). <br />137, i <br />fire -extinguishing system plans should be sub• <br />tl;!IWd to you to detenuine compliance with <br />applicable bedding, plumlanll, and lire codes. <br />FIREPLACES AND CHIMNEYS <br />138," <br />Chimneys should comply with Sections 3701 <br />and 3704. <br />139. <br />Fireplaces and barbecues should comply with <br />Section 3707. <br />FINISH WORK <br />140. <br />The interior wall and ceiling finishes should be <br />specified and comply with Table No. 42 8 and <br />Section 4203. <br />141. <br />Gypsum wallboard (interior lath and plaster) <br />cannot be installed on weather -exposed sur. <br />faces. Sections 4705. 1711. See Section 424 <br />for definition of weather exposed surface. <br />142: <br />SkyliChts should comply with Chapter 34. Plastic <br />skylights are allowed only under Ilia conditions <br />specified in Section 5205. <br />143. <br />Glass and glazing should comply with Chapter <br />54. Type and thickness of glass should be <br />specified. <br />Glass and glazing in hazar.rc :..:ocations should <br />144. <br />comply with Section 5406. <br />STRUCTURAL <br />145. <br />Special inspection in conformance with Section <br />305 is required for the followinP work: <br />(a) Shuctural concrete where the design is <br />based on an ultimate comVtestive strength <br />in excess of 2000 pounds per square inch. <br />(b) All welding except where done in the shop <br />of an approved fabricator. <br />(c) Installation o1 hiCh strength bolts. <br />(d) Prestressing work. <br />(e) Masonry work required by Chapter 24. <br />14G. <br />Soil classification in conformance with Table No. <br />28-B and ............................ pounds per square <br />foot soil hearing value used in design should <br />be specified on plans. Section 2905 (a). <br />147. <br />The'foundation investigation raper, menhrned in <br />plans was not included in data forwarded t5 us. <br />It should be submitted for review. <br />148. <br />All masonry or concrete elements resisting seis. <br />mic forces should qualify as reinforced elo. <br />ments. Section 2314 (1:) 3. <br />149. <br />Precast concrete wall panels are limited to an <br />• <br />lift ratio of 36 (25). Section 2616 (c). <br />150. <br />Wood members may support loads from ma. <br />sonry or concrete only under the conditions <br />specified In Section 2516 (a). <br />151. <br />Structural calculations should be submitted to <br />justify the adequacy of the structural system <br />In resisting seismic and wind leads, and sup. <br />porting dead and live loads. This includes <br />foundations. <br />152. <br />Justifying calculations and details should be pro• <br />videdfor............................................................ <br />......................................... <br />153. <br />Roofs shall be designed for snow loads of <br />...................... pounds per square400t. Section <br />2305 (c). <br />154. <br />The roof should be.. designed for uplift wind pres. <br />sures with doe consideration for lateral support <br />or compression flanges of flexural members. <br />155. <br />Floor load should consider a 20-pound per <br />square foot p:ntilion load. Section 2302 (b), <br />15G. <br />Marquees should be detnmeA for n GO Pound per <br />square fool live load. Table No. 23-A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.