My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2828 COLBY AVE CASCADE BANK 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
2828
>
CASCADE BANK
>
2828 COLBY AVE CASCADE BANK 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 10:17:32 AM
Creation date
8/12/2021 11:09:36 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2828
Tenant Name
CASCADE BANK
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
82- <br />A ftoor or landing not more than i inch below <br />the threshold is required on each side of an <br />exit door. Section 3303 (h). <br />83. <br />Doors should not project more than 7 inches in. <br />to the required corridor width when fully <br />opened or more than one halt into the required <br />corridor width when in any position. Section <br />3304(d).......................................................... <br />84. <br />Revolving (sliding) (overhead) doors are not per - <br />milled as exit doors. Section 3303 (f). <br />85,1 <br />Exit doors should provide immediate access to <br />an approved means of egress. Section 3303 <br />(g). Exiting through another room does not <br />comply. <br />85. <br />Corridors should have a minimum width of 44 <br />inches. Section 3304 (b). <br />87.''(Corridom <br />serving nonambulatory persons should <br />have an 8-foot minimum width. Section 3318 <br />83. <br />Dead end of corridors and exit balconies are <br />limited to 20 feet. Section 3304 (1). <br />Walls and ceilings of corridors should be of one - <br />hour fire -resistive construction. Section 3304 <br />(g). An architectural section through the corri. <br />dor is necessary to determine how this is <br />tt complished. <br />90. <br />Exterior exit balconies cannot project into an <br />area where protected openings are required <br />due to location on property. Section 3304 (1). <br />91. <br />openings into corridors should be pro. <br />IInterior <br />tected as specified in Section 3304 (h). <br />92. <br />Stairway .......................................... should have <br />a minimum width of ....... _........... Inches. Trim <br />and handrails should not project more than <br />3t/77 Inches into the required width. Section <br />3305 (b). <br />93. <br />Risers on stairways should not exceed 71/z <br />inches and runs should not be less than 10 <br />inch-s. Section 3305 (c). <br />94. <br />landings on stairways should have a dimension <br />In the direction of travel equal to the width of <br />the stairway but need not exceed 4 feet. Sec- <br />tion 3305 (f). <br />95.' <br />Landings should not be reduced in width more <br />than 31/l inches by a door when fully open. <br />Section 3305 M. <br />96. <br />portion of stairways should have an <br />IBasement <br />approved barrier where continuous to upper <br />floors in an exit enclosure. Section 3305 (M. <br />97.limited <br />Vertical distances between stairway landin6a are <br />to 12 feet. Section 3305 (h). <br />98. <br />° Handrails should be placed not less than 30 <br />Inches nor more than 34 inches above the <br />tread. Section 3305 (i). 'two handrails are re. <br />quired where stairways exceed 44 inches in <br />width. <br />99. <br />(Guardrails for stairs, balconies, and landings <br />should conform with Section 1714. Note that <br />maximum clearance between intermediate rails <br />is 9 inches. <br />IC0.1 <br />Openings in exterior walls within 10 feet of <br />exterior stairways should be protected with <br />self -closing three,fourths-hour fire -resistive as. <br />semblies. Section 3305 (k). <br />101."'Enclosed <br />usable space under interior stairways <br />should be protected on the enclosed side as <br />required for one hour fire-resi5hve eonslruc. <br />.tion. Section 3305 (1). <br />102. <br />Noncombustible exterior stairs are required. <br />Section 3305 (in). <br />103. <br />Exterior stairs should not project into an area <br />(yards or courts) where wall openings must be <br />protected. Section 3305 (m). <br />104.` <br />One stairway should extend to the roof. Section <br />3305 (n). It must be in a smokeproof enclosure <br />In buildings over 75 feet in height. Section <br />3309 (b). <br />105. <br />Six-foot 6-inch minimum tieadroom clearance for <br />' <br />sleirways should be indicated on plans. Section <br />3305 (o). Note that this is from a plane tan. <br />Sent to the stairway tread nosings. <br />106.1 <br />Ramp slopes should not exceed ore foot o, <br />................................ feet. Section 3306 (c) (d). <br />107. <br />Surface of ramps should be roughened or of a <br />nonslip material. Section 3306 (f). <br />108." <br />Stairways should be enclosed as specified in <br />Section 3308. <br />(a) One (two) -hour fire -resistive walls are re- <br />quired. <br />(b) Only exit doors are allowed to open into exit <br />enclosures. <br />(c) Doors should be labeled one (one -and -one. <br />half) -hour fire assemblies. <br />(d) Exit enclosures should include a corridor on <br />the ground floor extending to the exterior. <br />rire-resistive construction should be as re- <br />quired. for the exit enclosure, including pro- <br />tected openings. Only exit doors are per- <br />mitted to open into the corridor. <br />(e) An approved barrier is required at the <br />ground floor to prevent peop!e from acci- <br />dentally continuing to the lower level. <br />(f) Usable space is not allowed under the <br />stairs. <br />.............................................................................. <br />209.1 <br />One exit from the building should be a smoke - <br />proof enclosure complying with Section 3309. <br />110." <br />Openings into exit co,rrts less than 10 feel wide <br />should be protected with labeled 45-minute fire <br />assemblies. Section 3310 M. Also see "exit <br />court" definition in Section 3301 (c). Openings <br />more than 10 feet above the court floor are <br />exempt. _ <br />No openings other than requirer� exits are per- <br />121.v <br />mitted in exit passageways. The passageways <br />should be of .........................hour fire -resistive <br />construction. Section 3311 (a). <br />112. <br />Exit illumination and signs should be provided in <br />conformance with Section 3312. <br />113. <br />Aisle (cross aisle) in r.uditorium should have a <br />minimum width of ............................... Section <br />3313 (b). Section 3313 (e). <br />114 <br />Oanic hardware is required on exit doors serving <br />Group B Occupancies leaving an occupant load <br />of more than 100. Section 3316 (a). In lieu <br />of this, doors shall have no locks or latches. <br />1151 <br />.lain and side exits in confoimance with Sec- <br />tion 3315 are required for 0.2 (1) Occupancies. <br />Section 3316 (a). <br />11G,x <br />Corridors of Group C Occupancies should have a <br />width required by Section 3302 plus 2 feet, but <br />not less than 6 feet. Section 3317 (a). <br />117. <br />Each floor above or below the Ground floor level <br />of Group C Occupancies should have no less <br />than two exit stairs. Section 3317 (8)• <br />118. <br />Exit stairs serving an occupant load of mure <br />than 100 in a Group C Occupancy should have <br />a minimum clear width of 5 feet. Section 3317 <br />(g). <br />119.E <br />Lvery room with an occupant load exceeding <br />300 should have One of its exits into a separate <br />oril system. Section 3317 (b). <br />
The URL can be used to link to this page
Your browser does not support the video tag.