My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7807 EVERGREEN WAY LAUNDRY GENIUS 2022-02-03
>
Address Records
>
EVERGREEN WAY
>
7807
>
LAUNDRY GENIUS
>
7807 EVERGREEN WAY LAUNDRY GENIUS 2022-02-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2022 1:59:20 PM
Creation date
8/18/2021 2:33:11 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7807
Tenant Name
LAUNDRY GENIUS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />Mr. Rich Boyd <br />Cesco NW Acquisition LLC <br />Plan Check Number: B2101-005, First Building Review <br />March 11, 2021 <br />have been provided and relocated on the floor plan. The bi-level, non -refrigerated fountains <br />comply with ANSI 117.1, ADA, ANSI/NSF 61, and NSF/ANSI 372 - Listed by Underwriters <br />Laboratories to US standards. The T-shape'access is outlined on the revised floor plan. <br />6. The New Floor Plan on Sheet A-3 shows two mechanical rooms behind the dryers. The rooms <br />are required to have a minimum 36-inch wide clearance for all passageways. This should be <br />specified in the drawing. Note that the clearances around the water heaters and behind the <br />dryers in the north mechanical room do not appear to comply. See IMC Section 306.2: The <br />clearance behind the west bank of dryers is 3'-7" to provide access to electrical panel C-2.' <br />Required clearance behind the north bank of dryers is provided and noted on the plan. <br />Clearances to the front controls and connections for the water heaters are noted on the revised <br />plan; no access is required to the rear of the water heaters. <br />7. The building includes electrical panels in multiple locations that do not appear to provide the <br />minimum required electrical clearance per NEC-20 Section 110.26. The type and capacity of <br />each panel should be specified, and the minimum required clearance from the panel(s) to all <br />obstructions should be specified. No clearances should be less than 36 inches; the required <br />clearances may be larger and should be determined. The specifics of the electrical panels can <br />be found on the Electrical drawings. Clearances for the panels have been noted on the revised <br />floor plan; clearances are compliant and greater than 36 inches. <br />This review has been performed for general compliance with the building codes as adopted and <br />amended by the state of Washington and the city of Everett. Corrections and comments made <br />during the review process do not relieve the project from compliance with code and permit <br />requirements. The designers -of -record are responsible for a complete design in accordance with <br />the laws of the state of Washington. <br />If you have any questions or require additional clarification, please contact us. <br />Respectfully, <br />Drew Martin, P.E., S.E. <br />Associate Engineer / Commercial Plans Examiner <br />(425)257-8813 <br />dmartin@everettwa.gov <br />C:\Users\Mark Preston\Documents\Old Documents\Documents\AADRAWS\2020\Laundry <br />Genius\B2101-005_R1.wpd <br />3200 Cedar Street ® 425.257.8810 <br />Everett, WA 98201 425.257.8857 fax <br />everetteps@everettwa.gov <br />everettwa.gov/permits <br />Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.