The hoods have been submitted as a separate permit and the information related to the <br /> hood installation has been included in the building permit architectural drawings for <br /> reference purposes only. For coordination and continuity,we would like to keep the hood <br /> information in the building permit set. Hood specific items such as hood construction and <br /> supports have been clearly noted as "For Reference Only - Not For Construction", and <br /> clouded with Delta #1. Building modifications to facilitate the hood installations will be <br /> included as part of this building permit. <br /> d. Continuing with the previous comment, minor modifications to the building to facilitated <br /> installation and support of the hoods may be included in the building permit or the <br /> mechanical permit. If the sketch is retained, the building modifications should be clearly <br /> delineated as part of this permit. <br /> Modifications to the building to facilitate installation and support of the hoods will remain <br /> part of the building permit submission, labeled accordingly,and clouded with Delta#1. <br /> e. The sketch appears to show connection of Type I hoods to the existing wood frame walls. <br /> The hoods are required to comply with the minimum clearance requirements to <br /> combustible construction. Modifications to the wall should be included in the building <br /> permit to provide the minimum required clearance. See IMC Section 507.2.6. <br /> The existing walls will be provided with compliant wall protection at the Type I hood. See <br /> detail 6/A9.1 that has been added and clouded with Delta#1. <br /> 2. Partial Plan 2/A1.2 shows new exhaust ducts for the Type I hoods. It is presumed that the ducts <br /> between the hoods and the shafts will be constructed to provide the require fire protection with <br /> the adjacent combustible construction. The construction of the ducts should be shown in the <br /> drawings,or is required to be specified in the permit submittal for the hoods. See IMC Section <br /> 506.3.6. <br /> To clarify,we are installing one(1)Type I hood and one(1)Type II hood. I have noted this <br /> on drawing 2/A1.2 and clouded it with Delta#1.Within the building,the Type I hood will <br /> be wrapped using 3M Fire Barrier Duct Wrap 615+. Refer to detail 7/A9.1 clouded with <br /> Delta#1. <br /> 3. Partial Plan 2/A1.1 shows a new walk-in refrigeration unit accessed through a new door in the <br /> exterior wall. A detail should be provided showing that the doorway includes an accessible <br /> threshold. See IBC Section 1101.2 and ICC A117.1-09 Section 404.2.4. <br /> Please see details 9&10/A9.1 for threshold condition and flashing at the walk-in cooler <br /> door. Details have been clouded with Delta#1. <br /> 4. Details for the new interior walls are provided on Sheet A9.1. A detail specifying the top and <br /> bottom sill connections to the structure should be provided. The connections should be <br /> adequate for a 5 psf load on the wall surfaces. See IBC Section 1607.14. <br /> Please see detail 8/A9.1 for top and bottom sill connection detail. Detail has been clouded <br /> with Delta#1. <br /> Novenber 16,2020 CLARK I BARNES 2 <br />