• • <br /> Code Compliance Research Report CCRR-1043 Page 3 of 8 <br /> insulation may be applied to the maximum thickness in a Option 4: <br /> single pass. Maximum thickness ! Minimum application rate <br /> Vertical wall surfaces— j 0.9 gallon/100 ft2 No-Burn® <br /> 4.3 Thermal Barrier: 6-1/2 inches Plus ThB Intumescent <br /> Underside of roof decks, ' Coating <br /> 4.3.1 Application with a Prescriptive Thermal Barrier:Gaco ceilings, or the underside (14 mils WFT;9 mils DFT) <br /> F1850 insulation must be separated from the interior living of floors-9-1/2 inches <br /> space of the building by an approved thermal barrier of 1/2 <br /> inch thick gypsum board or an equivalent 15-minute thermal The coating must be applied over the insulation in <br /> barrier complying with,and installed in accordance with,IBC accordance with the coating manufacturer's instructions and <br /> Section 2603.4 or IRC Section R316.4. Exceptions are this report. Surfaces to be coated must be dry, clean, and <br /> provided in Sections 4.3.2 and 4.4. free of dirt, loose debris, and other substances that could <br /> interfere with the adhesion of the coating. The coating is <br /> When the insulation is separated from the interior living applied with low-pressure airless spray equipment. <br /> space of the building with minimum 1/2-inch-thick gypsum <br /> board,the maximum thickness is not limited. 4.4 Attics and Crawl Spaces: <br /> 4.3.2 Application without a Prescriptive Thermal Barrier: The insulation may be applied in attics and crawl spaces as <br /> Gaco F1850 insulation may be installed without the 15- described in either Section 4.4.1 or 4.4.2. When foam <br /> minute thermal barrier prescribed in IBC Section 2603.4 and insulation is installed in an attic or crawl space in accordance <br /> IRC Section R316.4, when installed as described in this with this section, a thermal barrier, as described in Section <br /> section. The insulation must be covered on all exposed 4.3.1,is not required between the foam plastic insulation and <br /> surfaces with intumescent coating as described in Option 1, the attic or crawl space but is required between the <br /> 2,3,or 4 below: insulation and the interior living space. <br /> Option 1: 4.4.1 Application with a Prescriptive Ignition Barrier: <br /> Maximum thickness Minimum application rate When Gaco F1850 insulation is installed within attics and <br /> Vertical wall surfaces—7- 1.1 gallon / 100 ft2 of IFTI ! crawl spaces where entry is made only for service of utilities, <br /> 1/2 inches DC315 Intumescent Coating the ignition barrier must be installed in accordance with IBC <br /> , Underside of roof decks, (18 mils WFT;12 mils DFT) Section 2603.4.1.6 or IRC Section R316.5.3 or R316.5.4, as <br /> ceilings, or the underside applicable. The ignition barrier must be consistent with the <br /> of floors—9-1/2 inches requirements for the type of construction required by the <br /> applicable Code and must be installed in a manner, so the <br /> Option 2: foam plastic insulation is not exposed. Gaco F1850 insulation <br /> Maximum thickness Minimum application rate as described in this section may be installed in unvented <br /> Vertical wall surfaces—5- 0.9 gallon/ 100 ft2 of IFTI attics in accordance with IBC Section 1202.3 or IRC Section <br /> 1/2 inches DC315 Intumescent Coating R806.5 at a minimum thickness of 1 inch. <br /> Underside of roof decks, ! (14 mils WFT;9 mils DFT) <br /> ceilings, or the underside 4.4.2 Application without a Prescriptive Ignition Barrier: <br /> of floors—9-11/2 inches <br /> 4.4.2.1 General:Gaco F1850 insulation may be installed in <br /> Option 3: attics and crawl spaces, without the ignition barrier <br /> Maximum thickness Minimum application rate <br /> prescribed in IBC Section 2603.4.1.6 and IRC Sections <br /> z" R316.5.3 and R316.5.4,subject to the following conditions: <br /> Vertical wall surfaces 7- 1.1 gallon/100 ft2TPR <br /> 1/2 inches Fireshell F10E Intumescent <br /> a. Entry to the attic or crawl space is only to service utilities, <br /> Underside of roof decks, Coating and no storage is permitted. <br /> ceilings, or the underside (18 mils WFT;12 mils DFT) b. There are no interconnected attic or crawl space areas. <br /> of floors—11 1/4 inches c. Air in the attic or crawl space is not circulated to other <br /> parts of the building. <br /> 545 E.Algonquin Road •Arlington Heights• Illinois• 60005 <br /> intertek.com/buildingMee <br /> Intertek PCA-101 <br /> Version:21 December 2017 SFT-CCRR-OP-40b <br />