My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3814 W MUKILTEO BLVD 2021-09-07
>
Address Records
>
W MUKILTEO BLVD
>
3814
>
3814 W MUKILTEO BLVD 2021-09-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2021 3:52:21 PM
Creation date
8/27/2021 9:34:13 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
3814
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> V 1 Code Compliance Research Report CCRR-1043 Page 2 of 8 <br /> Gaco F1850 insulation has a shelf life of 6 months on the Sections R202 and R806.5, based on testing in accordance <br /> polymeric isocyanate (A component) and 6months on the with ASTM E2178. <br /> resin (B component) when stored in factory-sealed <br /> containers at these temperatures. 3.2.4 Air Barrier: Gaco F1850 insulation, at a minimum <br /> thickness of 1 inch, is considered an air-barrier material in <br /> 3.1.2 DC315 Intumescent Coating: DC315 intumescent accordance with IECC Section C402.5.1.2.1,based on testing <br /> coating, manufactured by IFTI, Paint to Protect, is a water- in accordance with ASTM E2178. <br /> based coating supplied in 5-gallon pails and 55-gallon drums. <br /> The coating material has a shelf life of 24 months when The insulation, at a minimum thickness of 1 inch, is also <br /> stored in factory-sealed containers at a temperature considered an air barrier assembly in accordance with IECC <br /> between 41°F to 95°F. DC315 complies with ICC-ES AC456 as Section C402.5.1.2.2 based on testing in accordance with <br /> recognized in Intertek CCRR-1076. ASTM E2357. Window and door penetrations must be <br /> flashed in accordance with manufacturer's installation <br /> 3.1.3 TPR2 FIRESHELL Coatings: TPR2 FIRESHELL F10E instructions and the air barrier assembly must conform to <br /> coatings, manufactured by TPR2 Corporation, are water- IECC Section C402.5.1.1. <br /> based intumescent coatings supplied in 5-gallon pails and 55- <br /> gallon drums. The coatings have a shelf life of 1 year when 3.2.5 Vapor Permeance: Gaco F1850 has a vapor <br /> stored unopened at temperatures between 45°F and 95°F. permeance of less than 1 perm (5.7 x 1011 kg/Pa-s-m2) at a <br /> Fireshell F10E complies with ICC-ES AC456 as recognized in minimum thickness of 0.44 inch and may be used where a <br /> ICC-ES ESR-3997. Class II vapor retarder is required by the applicable Code. <br /> 3.1.4 No-Burn®Plus ThB Intumescent Coating:No-Burn® 3.2.6 Water-resistive Barrier: Gaco F1850 may be used as <br /> Plus ThB intumescent coating is a water-based coating an alternative to the water-resistive barrier specified in IBC <br /> supplied in 5-gallon pails and 55-gallon drums. The coating Section 1404.2 and IRC Section R703.2 when installed at a <br /> has a shelf life of 18 months when stored unopened at minimum of 1-inch thickness on exterior side of exterior wall <br /> temperatures between 40°F and 90°F. No-Burn®Plus ThB sheathing. <br /> complies with ICC-ES AC456 as recognized in IAPMO UES ER- <br /> 305. 4.0 INSTALLATION <br /> 3.2 Performance Characteristics: 4.1 General: <br /> 3.2.1 Surface Burning Characteristics: The insulation, at a Gaco F1850 must be installed in accordance with the <br /> maximum thickness of 4 inches and a nominal density of manufacturer's published installation instructions, the <br /> 2.1 pounds per cubic foot, has a flame-spread index of 25 or applicable Code, and this Research Report. The <br /> less and a smoke-developed index of 450 or less when tested manufacturer's published installation instructions and this <br /> in accordance with ASTM E84. Thicknesses of up to 9-1/2 Research Report must be strictly adhered to, and a copy of <br /> inches in ceilings and floors, and 7-1/2 inches in vertical the instructions must be available on the jobsite during <br /> surfaces,are recognized based on full scale fire performance installation. <br /> testing in accordance with NFPA 286. When the insulation is <br /> separated from the interior living space of the building with 4.2 Application: <br /> minimum 1/2-inch-thick gypsum board, the maximum <br /> thickness is not limited. Gaco F1850 insulation is spray-applied on the jobsite using a <br /> volumetric positive displacement pump as identified in the <br /> 3.2.2 Thermal Resistance: The insulation has thermal Gaco application instructions. The insulation must be applied <br /> resistance(R-value)at a mean temperature of 75°F as shown when the ambient temperature is greater than 32°F. The <br /> in Table 2. insulation must not be used in areas that have a maximum <br /> in-service temperature greater than 200°F.The foam plastic <br /> 3.2.3 Air Permeability: Gaco F1850 insulation, at a must not be used in electrical outlet or junction boxes or in <br /> minimum thickness of 1 inch,is considered air-impermeable contact with water,rain or soil. The foam plastic must not be <br /> insulation in accordance with IBC Section 1202.3 or IRC sprayed onto a substrate that is wet,or covered with frost or <br /> ice, loose scales,rust,oil,or grease. The insulation must be <br /> protected from the weather during and after application.The <br /> 545 E.Algonquin Road •Arlington Heights• Illinois•60005 <br /> intertek.com/building <br /> oicimarr <br /> Intertek PCA-101 <br /> Version:21 December 2017 SFT-CCRR-OP-40b <br />
The URL can be used to link to this page
Your browser does not support the video tag.