• <br /> • <br /> PC Comment Response Letter <br /> November 27, 2020 <br /> the stairs, and new new stairs. Structural plans showing all existing and new <br /> framing and foundations should be submitted for review. See IBCs Sections <br /> 1603.1 and 1604.4. <br /> Response: Structural plan sheets and calculation are provided by licensed <br /> structural engineer. There is no reframing on main floor level. <br /> 2. The new stairs require walls to provide a load path for the attic floor and roof <br /> framing above. Additional framing at the Main Floor level and foundations <br /> may be required. Framing plans should be included providing a complete <br /> load path. The framing at the landing should be specified. See Section <br /> 106.1.1. <br /> Response: Please refer to structural plan sheets and calculation. <br /> 3. The roof framing in Sections 1/A4.1 and 2/A4.1 do not appear to comply with <br /> the span requirements of Table R802.5.1(5). Note that the rafter sizes and <br /> spacing do not appear to be specified, but are presumed to be 2x4 at 24-inch <br /> spacing. The knee walls, presumed intended to comply with Section <br /> R802.5.1, do not bear on walls below. The sections do not specify the knee <br /> wall construction. The design may need to be revised. Calculations <br /> substantiating the design should be submitted for review. A header may be <br /> required over the stairway. See IBC Sections 107.2.1, 1603.1, 1604.1, and <br /> 1604.4. <br /> Response: Please refer to response #2. <br /> 4. The new Attic Floor framing does not appear to comply with the requirements <br /> of Chapter 5 and requires and engineered design. Calculations substantiating <br /> the design should be submitted for review. The floor framing may be <br /> required to support a portion roof load. The calculations should also <br /> substantiate the design of framing connections, vertical support framing, and <br /> foundations. See IBC Sections 1604.1 and 1604.4. <br /> Response: Please refer to response #2. <br /> 5. Section 4/A5.1 is referenced from Sections 1/A4.1 and 2/A4.1. The building <br /> sections appear to show new Attic Floor joists framing into the wall, which is <br /> not shown in Section 4/A5.1. The intended construction appears to cut the <br /> studs to allow bearing for the joists; the intended construction is not <br /> specified. The spacing of the wall framing is not clear and may not be <br /> consistent with the joist spacing; double top plate may be required per <br /> Section R 602.3.3. Other requirements for the construction, such as multiple <br /> (206)432-11111 WWW.YENDES.COM <br />