Laserfiche WebLink
� <br /> James Pirie JN 97072 <br /> • March 18, 1997 Page 11 <br /> Subsurface conditions can also vary between exploration I�cations. Such unexpected conditions <br /> frequently require making additional expe�ditures to attain a properly constructed project. It is <br /> recommended that the owner consider providing a contingency fund to accommodate such <br /> potential extra costs and risks. This is a standard recommendation for all projects. <br /> This report has been prepare� fi�,- the ;.�clusive use of James Pirie and his representatives for <br /> specific applica4ion to this project and site. Our recommendations and conclusions are based on <br /> observed site materials, and selective laboratory testing and engineering analyses. Our <br /> conclusions and recommendations are professional opinions derived in accordance with current <br /> standards of practice within the scope of our services and within budget and time constraints. No <br /> warranty is expressed or implied. The scope of our services does not include services related to <br /> construr.tion safety precautior��, and our recommendations are not intended to direct the <br /> contractor's methods, techniques, sequences, or procedures, except as specificaliy described in <br /> our report for consideratiun in design. We recommend including this report, in its entirety, in the <br /> project contract documents so the contractor may be aware of our findings. <br /> ADDITIONAL SERVICES <br /> • In addition to reviewing the final plans, Geotech Consultants, lnc. should be retained to provide <br /> geotechnical consultation, testing, and observation services during construction. This is to confirm <br /> that subsurface conditions are consistent with those indicated by our exploration, to evaluate <br /> whether earthwork and foundation constructicn activities comply with the general intent of the <br /> recommendations p�esented in this report, and to provide suggestions for design changes in the <br /> event subsurface conditiors differ from those anticipated prior to the start of construction. <br /> However, our work would not include the supervision or direction of the actual work of the <br /> contractor and its empl�yees or agents. Also, job and site safety, and dimensiona! measurements, <br /> wiil be the responsibility of the contractor. <br /> The scope of our work did not include an environmental assessment, but we can provide this <br /> service, if requested. <br /> The following plates are attached to complete this report: <br /> Plate 1 Vicinity Map <br /> Plate 2 Site Exploration Plan <br /> Plates 3 - 6 Test Pit Logs <br /> Plate 7 Footing Drain Detail <br /> GGOT[C!(CO4SULTANTS,INC. 1z/zD <br /> .. _ _.. ;. .� <br /> .. , C�„. � .� �y � n�•i*�t.,�is'��`� —`_,._ �..�� „�.. .:�. <br /> `�'�� �n. ��' � ��,�„� A �., ��`t�., U�MJlr�k.. ;t755:-., '.,y� �r'�k � :�. .•� ��C� <br /> . .. � ,.udW4' ..sk���.+'R`.� _ __ .a�..� - ..rw.✓nwv.qa+,v--.n+..�...........�......�+b�1i+Fii��:w nr . .. _. <br />