im <br />STRUCTURAL NOTES <br />1.1 ANY DISCREPANCY FOUND AMONG THE DRAWINGS, SPECIFICATIONS, THESE <br />NOTES, AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT <br />AND THE STRUCTURAL ENGINEER, WHO SHALL CORRECT SUCH DISCREPANCY IN <br />WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH <br />DISCREPANCY SHALL BE DONE AT THE CONTRACTORS RISK THE CONTRACTOR <br />SHALL VERIFY AND COORDINATE THE DIMENSIONS AMONG ALL DRAWINGS PRIOR <br />TO PROCEEDING WITH ANY WORK OR FABRICATION. THE CONTRACTOR IS <br />RESPONSIBLE FOR ALL ERECTION BRACING, FORMWORK AND TEMPORARY <br />CONSTRUCTION SHORING. <br />1.2 BY THE ACT OF SUBMITTING A BID FOR THE PROPOSED CONTRACT, THE <br />CONTRACTOR WARRANTS TRAT: <br />12.1 THE CONTRACTOR AND ALL SUBCONTRACTORS HE INTENDS TO USE <br />(INCLUDING AGENTS AND SUPPLIERS) HAVE CAREFULLY AND <br />THOROUGHLY REVIEWED THE DRAWINGS AND STRUCTURAL NOTES <br />AND HAVE FOUND THEM COMPLETE AND FREE FROM AMBIGUITIES <br />AND SUFFICIENT FOR THE PURPOSE INTENDED. <br />1.22 THE CONTRACTOR HAS CAREFULLY EXAMINED THE SITE OF THE <br />WORK AND THAT FROM HIS OWN INVESTIGATIONS, HE HAS SATISFIED <br />HIMSELF AS TO THE NATURE AND LOCATION OF THE WORK, AS TO THE <br />CHARACTER QUALITY, AND QUANTITIES OF MATERIAL AND <br />DIFFICULTIES TO BE ENCOUNTERED, AS TO THE EXTENT OF <br />EQUIPMENT AND OTHER FACILITIES NEEDED FOR THE PERFORMANCE <br />OF THE WORT( AND AS TO THE GENERAL AND LOCAL CONDITIONS, AND <br />OTHER ITEMS WHICH MAY IN ANY AFFECT THE WORK OR ITS <br />PERFORMANCE <br />1.2.3 THE CONTRACTOR AND ALL WORKERS HE INTENDS TO USE ARE <br />SKILLED AND EXPERIENCED IN THE TYPE OF CONSTRUCTION <br />REPRESENTED BY THE DRAWINGS AND DOCUMENTS BID UPON. <br />11.4 NEITHER THE CONTRACTOR NOR ANY OF HIS EMPLOYEES, AGENTS, <br />INTENDED SUPPLIERS, OR SUBCONTRACTORS HAVE RELIED UPON <br />ANY VERBAL REPRESENTATIONS ALLEGEDLY AUTHORIZED OR <br />UNAUTHORIZED FROM THE OWNER OR HIS EMPLOYEES OR AGENTS, <br />INCLUDING THE ARCHITECT OR ENGINEERS, IN ASSEMBLING THE BID <br />FIGURES. <br />1.2.5 THE REQUIREMENTS CONTAINED WITHIN THIS SECTION SUPERSEDE <br />REQUIREMENTS AND/CR RECOMMENDATIONS CONTAINED IN THE AISC <br />'CODE OF STANDARD PRACTICE FOR STEEL BUILDING AND BRIDGES', <br />AS WELL AS CASE DOCUMENT 962-D A GUIDELINE ADDRESSING <br />COORDINATION AND COMPLETENESS OF STRUCTURAL <br />CONSTRUCTION DOCUMENTS' <br />12.6 THE CONTRACTORAND ALL SUBCONTRACTORS HE INTENDS TO USE <br />ARE AWARE OF AND ACKNOWLEDGE THAT CLOSE COORDINATION <br />AMONG ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL <br />AND OTHER TRADE DRAWINGS IS REQUIRED. <br />12.7 THE CONTRACTOR AND ALL SUBCONTRACTORS HE INTENDS TO USE <br />SHALL RECOGNIZE THAT THE PROJECT CONTRACT DOCUMENTS <br />INCLUDE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND <br />ELECTRICAL AND OTHER TRADE DRAWINGS AND SPECIFICATIONS. <br />1.2.8 THE CONTRACTOR AND ALL SUBCONTRACTORS ACKNOWLEDGE THAT <br />CLOSE COORDINATION BETWEEN DISCIPLINES INCLUDED WITHIN THE <br />CONTRACT DOCUMENTS IS NECESSARY. ELEMENTS THAT WILL <br />REQUIRE CLOSE COORDINATION BY THE CONTRACTOR INCLUDE (BUT <br />ARE NOT LIMITED TO): <br />A VERIFICATION OF ALL DIMENSIONS INDICATED ON THE <br />MECHANICAL AND STRUCTURAL DRAWINGS <br />B. DETERMINATION OF ALL ANCHOR LOCATIONS <br />C. DETERMINATION OF TOP OF FOOTING ELEVATIONS. <br />D. MECHANICAJELECTRICAL EQUIPMENT LOCATIONS AND WEIGHTS <br />E LOCATION AND SITE OF ALL MECHANICAU ELECTRICAL <br />PENETRATIONS THROUGH WALLS AND FLOORS/ ROOFS <br />1.2.10 THE CONTRACTOR AND ALL SUBCONTRACTORS HE INTENDS TO USE <br />SWILL MAKE CONSIDERATION FOR, AND INCLUDE MONIES FOR THE <br />ABOVE IN THE PREPARATION OF THEIR BIDS. <br />1.2.11 THE CONTRACTOR SHALL NOT SCALE THE MECHANICAL AND <br />STRUCTURAL DRAWINGS FOR LOCATIONS OF ELEMENTS NOTED <br />ABOVE. <br />1.2.12 ELECTRONIC COPIES OF THE STRUCTURAL DRAWINGS (PDFS, CAD <br />DRAWINGS OR BIM MODELS) MAY BE PROVIDED TO THE CONTRACTOR <br />FOR THEIR USE THESE FILES MAY BE PROVIDED AT THE REQUEST OF <br />THE CONTRACTOR FOR THEIR CONVENIENCE ONLY. THE <br />CONTRACTOR AGREES THAT THESE FILES SHALL NOT SUPERCEDE <br />INFORMATION SHOWN ON THE ORIGINAL BID/ CONSTRUCTION <br />DOCUMENTS. THE CONTRACTOR AGREES TO HOLD THE STRUCTURAL <br />ENGINEER HARMLESS FOR ANY ERRORS OR DISCREPANCIES <br />CONTAINED WITHIN THESE ELECTRONIC FILES. <br />1.2.13 THE BID FIGURE IS BASED SOLELY UPON THE CONSTRUCTION <br />CONTRACT DOCUMENTS AND PROPERLY ISSUED WRITTEN OR VERBAL <br />REPRESENTATIONS. <br />1.3 EXISTING BUILDING CONDITIONS <br />1.3.1 STRUCTURAL DESIGN IS BASED ON EXISTING FRAMING CONDITIONS <br />OBSERVED AND FIELD MEASURED AND/OR DESCRIBED IN ORIGINAL <br />CONSTRUCTION DRAWINGS. FIELD OBSERVATIONS DURING DESIGN <br />ARE LIMITED TO AREAS OPEN TO VIEW AND ACCESSIBLE. <br />1.3-2 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING FRAMING <br />CONDITIONS FOR COMPLIANCE WITH THE INFORMATION SHOWN ON <br />THE STRUCTURAL DRAWINGS PRIOR TO DEMOLITION AND <br />CONSTRUCTION. AS43UILT DEVIATIONS FROM THE INFORMATION <br />SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER <br />PRIOR TO EXECUTION OF WORK IN THE AREAS AFFECTED BY THE <br />DISCREPANCY, <br />1.4 CODES <br />1.4.1 <br />ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CON FORM TO <br />THE 2D12 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND <br />ADOPTED BY THE LOCAL BUILDING AUTHORITY. <br />1.42 <br />ALL REFERENCES TO OTHER CODES, STANDARDS AND <br />SPECIFICATIONS, (ACI, ASTM, ETC.), SHALL BE FOR THE EDITION <br />CURRENTLY REFERENCED BY IBC AS AMENDED AND ADOPTED BY THE <br />LOCAL BUILDING AUTHORITY. <br />1.5 DESIGN CRITERIA <br />1.5.2 <br />UNIFORM LOADS: <br />LOCATION LIVE LOAD DEAD LOAD <br />ROOF 25 PSF (SNOW) ACTUAL 2. <br />STRUCTURAL 125 PSF ACTUAL <br />SLAB ON GRADE <br />THIS IS NOT A GROUND SNOW LOAD <br />1.5.6 WIND LOADS (PER IBC SECTION 16M AND ASCE 7 CHAPTERS 26 THRU <br />30): <br />ULTIMATE DESIGN WIND SPEED (VL�: 110 MPH <br />RISK CATEGORY: I <br />WIND EXPOSURE B <br />ENCLOSED STRUCTURE <br />TOPOGRAPHIC FACTOR(K4) 1.0 <br />COMPONENTS AND CLADDING: ULTIMATE DESIGN WIND PRESSURES <br />TO BE USED FOR THE DESIGN OF EXTERIOR COMPONENT AND <br />CLADDING MATERIALS IS AS FOLLOWS: <br />ZONE:1-16.0/-21.8 PSF(10 SO FT) <br />ZONE:2 +1&0/S6.5 PSF(10 SO FT) <br />ZONE:3 +16.0/S5.0 PSF (10$0 FT) <br />ZONEA +19.9/-21.6 PSF(10 SQ FT) <br />ZONE:5 +19.91.28.6 PSF(10 SO Fr) <br />1.5.7 SEISMIC LOADS (PER IBC SECTION 1613 AND ASCE 7 CHAPTERS 1 i <br />THRU 13): <br />RISK CATEGORY: I <br />SEISMIC IMPORTANCE FACTOR (6): 1.0 <br />Sr: 1.441 <br />S,: 0.553 <br />SITE CLASS: D <br />so,,: 0.961 <br />Set: 0,553 <br />SEISMIC DESIGN CATEGORY: D <br />DESIGN BASE SHEAR 0.154WP <br />ANALYSIS PROCEDURE USED: ASIDE 13.3.1 <br />NONSTRUCTURAL <br />COMPONENTS <br />1.6 STATEMENT OF SPECIAL INSPECTIONS <br />SEE STATEMENT OF SPECIAL INSPECTION AND TESTING SHEET S02 <br />1.7 SHOP DRAWINGS <br />1.7.1 SUBMIT SHOP DRAWINGS TO THE ARCHITECT/ENGINEER FOR THE <br />FOLLOWING: <br />A CONCRETE MIX DESIGN SUBMITTALS <br />B. REINFORCING STEEL <br />C. STRUCTURAL AND MISCELLANEOUS STEEL INCLUDING WELD <br />INSERTS AND ANCHORS <br />1.7.3 SHOP DRAWING REVIEW NOTES <br />A ENGINEER OF RECORD SHALL REVIEW SHOP DRAWINGS FOR <br />GENERAL CONFORMANCE WITH THE PROJECT CONSTRUCTION <br />DOCUMENTS (PLANS AND SPECIFICATIONS). <br />B. ENGINEER OF RECORD REVIEW OF SHOP DRAWINGS SHALL NOT <br />RELIEVE THE GENERAL CONTRACTOR OF THEIR RESPONSIBILITY <br />FOR REVIEW OF THE SHOP DRAWINGS FOR COMPLIANCE WITH <br />THE PROJECT REQUIREMENTS. <br />C. APPROVAL OF THE SHOP DRAWINGS BY THE ENGINEER OF <br />RECORD SHALL NOT BE CONSIDERED AS A GUARANTEE BY THE <br />ENGINEER THAT THE SHOP DRAWINGS COMPLY WITH ALL <br />PROJECT REQUIREMENTS. <br />D. CONCURRENT SHOP DRAWING RENEW SHALL ONLY BE <br />PERMITTED IF APPROVED BY THE ARCHITECTIENGINEER OF <br />RECORD PRIOR TO THE START OF SHOP DRAWING REVIEW. <br />9 <br />1.8 MISCELLANEOUS <br />1.8.1 VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. <br />1.8.2 VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOORS, ROOF <br />AND WALLS WITH MECHANICAL AND ELECTRICAL DRAWINGS. <br />1.8.3 CONSTRUCTION DETAILS NOT SPECIFICALLY SHOWN ON THE <br />DRAWINGS SHALL FOLLOW SIMILAR DETAILS OF SECTIONS OF THIS <br />PROJECT AS APPROVED BY THE ENGINEER <br />1.8.4 SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR DIMENSIONS AND <br />LOCATIONS OF OPENINGS NOT DIMENSIONED OR SHOWN ON <br />STRUCTURAL. PLANS. <br />1.8.5 SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATIONS AND <br />WEIGHTS OF ALL MECHANICAL AND ELECTRICAL EQUIPMENT <br />INCLUDING HOUSEKEEPING PADS. <br />SITE PREPARATIONISOIL REMEOLLAT10N <br />2.1 SOIL DATA <br />ALLOWABLE SOIL PRESSURE 2500 PSF PER ORIGINAL BUILDING DRAWINGS. <br />ALLOW 33-1/3% INCREASE FOR LOADS FROM WIND OR SEISMIC ORIGIN. <br />2.2 EXCAVATION <br />EXCAVATE TO DEPTH SHOWN AND TO FIRM UNDISTURBED MATERIAL. <br />OVER -EXCAVATIONS SHALL BE BACKFILLED WITH LEAN CONCRETE (f,=5 &1200 <br />PSI) OR STRUCTURAL FILL AT THE CONTRACTORS EXPENSE. EXERCISE <br />EXTREME CARE DURING EXCAVATION TO AVOID DAMAGE TO BURIED LINES, <br />TANKS, AND OTHER CONCEALED ITEMS. UPON DISCOVERY, DO NOT PROCEED <br />WITH WORK UNTIL RECEIVING WRITTEN INSTRUCTIONS FROM THE ENGINEER A <br />COMPETENT REPRESENTATIVE OF THE OWNER SHALL INSPECT ALL FOOTING <br />EXCAVATIONS FOR SUITABILITY OF BEARING SURFACES PRIOR TO PLACEMENT <br />OF REINFORCING STEEL. PRONOE DRAINAGE AS NECESSARY TO AVOID <br />WATER -SOFTENED SUBGRADE. <br />2.3 FILL AND COMPACTION <br />STRUCTURAL FILL OTHER THAN PEA GRAVEL SHALL BE GRANULAR PLACED IN <br />&INCH LIFTS AND COMPACTED TO AT LEAST 95%OF ITS MAXIMUM DRY DENSITY <br />AS DETERMINED BY ASTM D-1557 (MOD PROCTOR). PEA GRAVEL FILL SHALL. <br />HAVE A MAXIMUM PARTICLE SIZE OF 3V DIAMETER. <br />STRUCTURAL CONCRETE <br />3.1 GENERAL <br />ALL CONCRETE SHALL BE HARD ROCK CONCRETE MEETING THE REQUIREMENTS <br />OF ACI-301,'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS.' <br />PROPORTIONING OF INGREDIENTS FOR EACH CONCRETE MIX SHALL BE BY <br />METHOD 2 OR THE ALTERNATE PROCEDURE GIVEN IN ACI-301. PLACE <br />CONCRETE PER ACF304 AND CONFORM TO ACISO4 (306) FOR WINTER <br />CONCRETING AND ACI-605(305) FOR HOT WEATHER CONCRETING. USE <br />INTERIOR MECHANICAL VIBRATORS WITH 7,000 RPM MINIMUM FREQUENCY. DO <br />NOT OVER -VIBRATE. CONCRETE SHALL BE PLACED MONOLITHICALLY BETWEEN <br />CONSTRUCTION OR CONTROL JOINTS. PROTECT ALL CONCRETE FROM <br />PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURE FOR SEVEN <br />DAYS AFTER PLACING. <br />3.2 STRENGTH <br />TWENTY-EIGHT DAY COMPRESSIVE STRENGTHS SHALL BE AS FOLLOWS: <br />FOOTINGS 4000 PSI <br />CONCRETE SUPPLIER TO PROVIDE TEST RECORDS PER SECTION 5.3 OF ACI 318. <br />3.3 MATERIALS <br />3.3.1 CEMENT: ASTM C150, TYPE I OR TYPE 11. ENGINEERS APPROVAL IS <br />NEEDED FOR USE OF TYPE III CEMENT. <br />3.3.2 COARSE AND FINE AGGREGATE ASTM C33. <br />3.3.3 WATER SHALL BE CLEAN AND POTABLE. <br />3.3.4 FLYASH: ASTM C818 CLASS C (CLASS F SHALL BE ALLOWED IF <br />PERMITTED BY THE STRUCTURAL ENGINEER) <br />3.3.5 GROUND GRANULATED BLAST FURNACE SLAG (GGBFS): ASTM C989 <br />GRADE 100 OR 120. GGBFS SHALL NOT BE PERMITTED UNLESS <br />RENEWED AND APPROVED BY THE STRUCTURAL ENGINEER MIX <br />DESIGNS SUBMITTED INCLUDING GOOFS SHALL INCLUDE SHRINKAGE <br />TEST RESULTS AT 28 DAYS. <br />3.4 ADMIXTURES <br />3.4.1 WATER REDUCING ADMIXTURE: ASTM C494. ADMIXTURES SHALL BE <br />USED IN EXACT ACCORDANCE WITH MANUFACTURERS <br />INSTRUCTIONS. <br />3.4.2 WATER REDUCING ADMIXTURES SHALL BE USED AT ALL HEAVILY <br />CONGESTED AREAS Q.E. CONCRETE BEAMS, COLUMNS AND WALLS <br />WITH REINFORCING SPACING OF 4- OR LESS) <br />3.4.3 CONCRETE USING ADMIXTURES TO PRODUCE FLOWABLE CONCRETE <br />MAY BE USED SUBJECT TO ENGINEERS APPROVAL <br />3.4.4 AR ENTRAINMENT: ASTM C260 AND ASTM C494 ENTRAIN 5% <br />PLUSIMINUS 1.5% BY VOLUME IN ALL CONCRETE EXPOSED TO <br />WEATHER. <br />3.4.5 NO OTHER ADMIXTURES PERMITTED UNLESS APPROVED BY THE <br />ENGINEER. <br />3.10 <br />FORMWORK AND SHORING <br />sties... <br />corm.Mrnrvr,. <br />3.10.1 FOLLOW RECOMMENDED PRACTICE FOR CONCRETE FORMWORK <br />3.11 <br />(ACI-34T).� <br />REINFORCING STEEL <br />3.11.1 DETAIL, FABRICATE, AND PLACE PER ACI-315 AND ACI-318. SUPPORT <br />T A C O M A S E A T T L E <br />REINFORCEMENT WITH APPROVED CHAIRS, SPACERS, OR TIES. <br />2215 North 3M Sheer, Sub 300, Tacana, WA 98403 <br />253.3832422 to <br />3.11.2 DEFORMED BAR REINFORCEMENT: ASTM A815 GR 60 <br />12DO SbJh AvmA State 1620. Seaft, WA 98101 <br />2082872425 is <br />3.11.8 EXCEPT AS NOTED SPECIFICALLY ON THE DRAWINGS, ALL CONCRETE <br />REINFORCEMENT SHALL BE LAPSPUCED AS FOLLOWS: <br />Protect Tine: <br />X6 AND SMALLER 48 X BAR DIAMETER <br />X7 AND LARGER 56 X BAR DIAMETER <br />CASCADE COFFEE <br />NO MORE THAN 50% HORIZONTAL ORVERTKAL BARS SHALL BE <br />SPLICED ATONE LOCATION <br />NEW EXTERIOR <br />3.11.10 EXCEPT AS NOTED SPECIFICALLY ON THE DRAWINGS, PROVIDE <br />EQUIPMENT <br />CORNER BARS TO MATCH QUANTITY AND DIAMETER OF HORIZONTAL <br />REINFORCEMENT AND LAP WITH HORIZONTAL REINFORCEMENT AS <br />FOLLOWS: <br />X6 AND SMALLER 48 X BAR DIAMETER <br />#7ANDLARGER 56XWDLAME R <br />CASCADE COFFEE, INC. <br />THESE CORNER BARS SHALL BE PLACED AT ALL CORNERS AND <br />INTERSECTIONS IN CONCRETE FOOTINGS AND WALLS. <br />1525 75tt ST $W SUITE 100 <br />3.12 <br />CONCRETE COVER ON REINFORCING SHALL BE AS FOLLOWS (UNLESS SHOWN <br />EVERETT, WA 982(13 <br />OTHERWISE): <br />BOTTOM OF FOOTINGS 3- <br />FORMED EARTH FACE AND SLAB ON GRADE 2' <br />Job No <br />3.14 <br />CONDUIT AND PIPING EMBEDDED IN CONCRETE <br />2150149.20 <br />3.14.1 ELECTRICAL CONDUIT SHALL NOT BE PLACED WITHIN A SLAB ON <br />GRADE, BUT PLACED BELOW THE SLAB IN THE SUB -BASE <br />Issue Set a Date: <br />3.15 <br />GROUT FOR SEARING PLATES <br />PERMIT SET <br />THE NON -SHRINK GROUT SHALL MEET ASTM Cl IN GRADE B OR EQUIVALENT <br />(MASTERFLOW 928 BY BASF OR APPROVED EQUIVALENT). GROUT SHALL BE A <br />PRE -PACKAGED HYDRAULIC CEMENT BASED MINERAL AGGREGATE GROUT, <br />MAY 6, 2015 <br />MDED, PLACED AND CURED AS RECOMMENDED BY THE MANUFACTURER <br />COMPRESSIVE STRENGTH SHALL EXCEED 6000 PSI AT 28 DAYS. <br />5. METALS <br />52 <br />STRUCTURAL STEEL GENERAL REQUIREMENTS <br />it. Sq yD <br />fi '4i a <br />521 MISCELLANEOUS PLATES SHALL BE ASTM A36 FY=36 KSI. <br />525 STEEL ANCHORAGE ELEMENTS <br />4. e <br />A EXPANSION ANCHORS IN CONCRETE SHALL BE STAINLESS STEEL <br />ssMAL ' <br />WHEN INSTATED IN EXTERIOR ENVIRONMENTS, AND CARBON <br />STEEL AT ALL OTHER LOCATIONS, UNLESS NOTED OTHERWISE <br />EXPANSION ANCHORS SHALL BE EITHER HILTI KWIK BOLT TZ (ICC <br />Iaysc a oocvuwrs <br />ESR-1917), SIMPSON STRONG-BOLT2 (ICC ESR-3037), POWERS <br />m <br />POWERSTUD+SD2 ([CC ESR-2502), OR APPROVED EQUIVALENT <br />WITH A CURRENT CODE REPORT THAT COMPLIES WITH THE <br />CURRENT EDITION OF THE IBC RATED FOR USE IN CRACKED <br />CONCRETE AND RATED TO RESIST WIND AND SEISMIC FORCES IN <br />THE SEISMIC DESIGN CATEGORY NOTED IN SECTION 1.5. <br />S. ADHESIVE ANCHORS IN CONCRETE SHALL BE THREADED ANCHOR <br />RODS OR REPAR DOWELS USING AN INJECTABLE ADHESIVE <br />EITHER HILTI HIT-HY 200 (ICC ESR3187), SIMPSON ATAP (IAPMO <br />ER-263), OR APPROVED EQUIVALENT WITH A CURRENT CODE <br />REPORT THAT COMPLIES WITH THE CURRENT EDITION OF THE IBC <br />RATED FOR USE IN CRACKED CONCRETE AND RATED TO RESIST <br />WIND AND SEISMIC FORCES IN THE SEISMIC DESIGN CATEGORY <br />NOTED IN SECTION 1.5. <br />527 METAL PROTECTION: ALL STEEL. EXPOSED TO WEATHER, MOISTURE, <br />SOIL, OR AS NOTED SHALL BE GALVANIZED PER ASTM A-123 OR A153 <br />ASAPPLICABLE. ALL OTHER STEEL SURFACES SHALL BE SHOP <br />PRIMED AFTER FABRICATION. <br />REPAIR ALL DAMAGED AREAS OF GALVANIZED PARTS SUCH AS FIELD <br />WELDS, ETC. APPLY REPAIR COATING THICKNESS GREATER THAN OR <br />THICKNESS. <br />EQUAL TO ORIGINAL ZINC COATING <br />8 <br />0 <br />Revisions. <br />Sneer Tine: <br />GENERAL STRUCTURAL <br />NOTES <br />Des-e0 bv: Drawn bv: Cbecke,l bv: <br />AS DR SS <br />Sham nIn <br />S0.1 <br />of sheets <br />