My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1920 100TH ST SE 2021-12-13
>
Address Records
>
100TH ST SE
>
1920
>
1920 100TH ST SE 2021-12-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2021 8:41:51 AM
Creation date
9/16/2021 9:12:15 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SE
Street Number
1920
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br />r-"q <br />Lighting, • • and Lwectrical Permit Checklist, Pti. 4 LTG-CHK <br />2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 <br />Project Title: SEA MAR EVERETT MEDICAL CLINIC <br />Date 6/18/2019 <br />The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />Applicability <br />Location in <br />Building Department <br />(yes,no,na) <br />Code Section <br />Component <br />Compliance information required in permit documents <br />Documents <br />Notes <br />MOTORS & TRANSFORMERS <br />NA <br />C405.6 <br />Electrical tranformers <br />Include electrical transformer schedule on electrical plans; <br />indicate transformer size, efficiency, or exception taken <br />NA <br />C405.7 <br />Dwelling unit <br />electrical energy <br />Indicate on electrical plans that each dwelling unit in Group R-2 <br />consumption <br />has a separate electrical energy meter <br />Electric motor <br />Include all motors, including fractional hp motors, in electric <br />NA <br />C405.8 <br />efficiency <br />motor schedule on electrical plans; indicate hp, rpm, rated <br />efficiency, or exception applied <br />For luminaires in each elevator cab, provide calculated average <br />efficacy of combined fixtures that indicates efficacy is not less <br />than 35 lumens per watt; <br />Indicate rated watts per cfm for elevator cab ventilation fans do <br />NA <br />C405.9.1 <br />Elevator cabs <br />not exceed 0.33 watts per cfm; <br />Indicate automatic controls that de -energize lighting and <br />ventilation fans when elevator is stopped and unoocupied for a <br />period of 15 minutes or more <br />Escalators and <br />Indicate escalators comply with ASME A17.1/CSA B44; <br />NA <br />C405.9.2 <br />moving walks <br />automatic controls are configured to reduce operational speed <br />to the minimum permitted when not in use <br />NA <br />C405.9.3 <br />Regenerative drive <br />Indicate all one-way down or reversible escalators are provided <br />with a variable frequency regenerative drive <br />Identify all controlled and uncontrolled receptables on electrical <br />plans in each space in which they are required; include <br />Controlled <br />receptacle configuration such as spacing between controlled <br />NA <br />C405.10 <br />and uncontrolled, duplex devices, etc; <br />receptacles <br />-- <br />Indicate on plans whether the method of automatic control for <br />-- <br />each controlled receptable zone is by occupant sensor or <br />programmable time -of -day control <br />If "no" is selected for any question, provide explanation: <br />ESSENTIALLY THERE IS NO NEED FOR OTHER SPECIFIC LIGHT FIXTURE TO THE FUNCTION OF SPACE (IE. UNDERMOUNT <br />TASK LIGHTING, ETC.) <br />End of Lighting, Motor & Transformer Permit Documents Checklist <br />
The URL can be used to link to this page
Your browser does not support the video tag.