My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1920 100TH ST SE 2021-12-13
>
Address Records
>
100TH ST SE
>
1920
>
1920 100TH ST SE 2021-12-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2021 8:41:51 AM
Creation date
9/16/2021 9:12:15 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SE
Street Number
1920
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor,and bectrical Permit Checklist, ' g.-3 LTG-CHK <br />2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all Rt Revised July 2016 <br />Project Title: SEA MAR EVERETT MEDICAL CLINIC <br />Date 6/18/2019 <br />The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />Applicability <br />ILocation <br />in <br />Building Department <br />(yes,no, na) I <br />Code Section <br />Component <br />Compliance information required in permit documents <br />Documents <br />Notes <br />INTERIOR LIGHTING POWER & EFFICACY <br />Include all luminaires in lighting fixture schedule; indicate fixture <br />types, lamps, ballasts, and manufacturer's rated watts per <br />fixture; <br />Identify spaces eligible for lighting power exemption on plans <br />C405.4.1 <br />Total connected <br />and in compliance forms; indicate the exception applied; <br />NO <br />C405.4.1 <br />C405.4.2 <br />interior lighting power <br />Identify lighting equipment eligible for lighting power exemption <br />in fixture schedule and in compliance forms; indicate the <br />exception applied; <br />Indicate that exempt lighting equipment is in addition to general <br />area lighting and is controlled independently <br />YES <br />C405.3 <br />Exit signs <br />Indicate location of exit signs on plans and rated watts per <br />A0.01 <br />fixture in lighting fixture schedule (maximum 5 watts per fixture) <br />If high efficacy exception is applied to permanently installed <br />Lighting in dwelling <br />lighting fixtures in dwelling units, indicate in lighting fixture <br />NA <br />C405.1 <br />units -lamp efficacy <br />schedule if lamps in fixtures are high efficacy per R404.1. <br />Calculate percentage of fixtures with high efficacy lamps in <br />project (min 75% to comply with exception). <br />Reduced lighting <br />For project with dwelling units, to comply with additional <br />power density - <br />efficiency package option indicate in lighting fixture schedule if <br />NA <br />C406.3 <br />dwelling unit lamp <br />lamps in fixtures have efficacy rating of 60 lumens per watt or <br />efficacy <br />more. Calculate percentage of fixtures with lamps that have this <br />efficacy rating (min 95% to comply with option). <br />Lighting Power Calculation - Indicate compliance path taken <br />Complete required compliance forms — proposed wattage per <br />YES <br />C405.4.2.1 <br />Building Area Method <br />building area does not exceed maximum allowed wattage per <br />AE2.03 <br />building area. Identify locations of building areas on plans <br />Complete required compliance forms — total proposed wattage <br />YES <br />C405.4.2.2 <br />Space -By -Space <br />does not exceed maximum allowed wattage. Identify locations <br />AE2.03 <br />Method <br />of space types on plans, including retail display areas, lobby art <br />& exhibit display areas, and ceiling heights as applicable <br />To comply with additional efficiency package option, <br />Reduced lighting <br />demonstrate in compliance forms that total connected interior <br />YES <br />C406.3 <br />power density <br />lighting wattage is 75 /o less than the total maximum allowed <br />AE2.03 <br />lighting wattage via Building Area Method or Space -By -Space <br />Method <br />EXTERIOR <br />LIGHTING POWER & EFFICACY <br />Include all luminaires in lighting fixture schedule; indicate fixture <br />types, lamps, ballasts, and manufacturer's rated watts per <br />fixture; <br />Total connected <br />Identify exterior applications eligible for lighting power <br />NA <br />C405.5.2 <br />exterior lighting <br />exemption on plans and in compliance forms; indicate exception <br />applied; <br />power <br />Indicate that exempt exterior lighting is controlled independently <br />from non-exempt exterior lighting; include exception claimed for <br />each fixture or group of fixtures under exception category <br />NA <br />Table <br />C405.5.2(1) <br />Exterior lighting zone <br />Indicate building exterior lighting zone as defined by the AHJ <br />Exterior building <br />For building grounds fixtures rated at greater than 100 watts that <br />NA <br />C405.5.1 <br />grounds lighting <br />are complying based on efficacy, indicate rated lamp efficacy (in <br />lumens per watt) in fixture schedule <br />Exterior lighting <br />Complete required compliance form — proposed wattage for <br />NA <br />C405.5.2 <br />power calculations <br />exterior lighting plus base site allowed does not exceed <br />maximum allowed <br />
The URL can be used to link to this page
Your browser does not support the video tag.