Laserfiche WebLink
47KeK1SPEC- Project: Project Type: Type <br /> Location: Everett, WA <br /> Folder: Folder <br /> Date: 3/4/21 9:05 AM <br /> RedSpecTM by RedBuiltTM Designer: SynThesis <br /> v7.1.12 Comment: Use 48" o.c. with 10 psf live and 10 psf dead load <br /> 16" Red-I90TM @ 24" o.c. <br /> This product meets or exceeds the set design controls for the application and loads listed <br /> DESIGN CONTROLS % Design Allow. DOL Combination Pattern Pass/Fail <br /> Shear(Ib) 40% 1400 3512 Roof(125%) 1.0D+1.0Lr All Spans PASS <br /> Positive Moment(ft-lb) 75% 12250 16394 Roof(125%) 1.0D+1.0Lr All Spans PASS <br /> DEFLECTIONS(in) % Design Allow. Design Allow. Combination Pattern Pass/Fail <br /> Span Live 66% 1.154 1.750 L/364 L/240 1.0D+1.0Lr All Spans PASS <br /> Span Total 99% 2.309 2.333 L/ 182 L/180 1.0D+1.0Lr All Spans PASS <br /> SUPPORTS Support 1 Support 2 <br /> Live Reaction,Critical(Ib) (DOL%) 700(125) 700(125) <br /> Dead Reaction(Ib) 700 700 <br /> Total Reaction (lb) (DOL%) 1400(125) 1400(125) <br /> Bearing Flush Flush <br /> Support Ledger Wall <br /> Req'd Bearing,No Stiffeners(in) 1.75 1.75 <br /> Req'd Bearing,Stiffeners(in) - - <br /> HANGERS Model Top Face Member Header Size <br /> Left None Selected <br /> Right None Selected <br /> SPANS AND LOADS <br /> Dimensions represent horizontal design spans. Member Slope: 0/12 <br /> 35'-0.0" <br /> APPLICATION LOADS <br /> Type Units DOL Live Dead Partition Tributary Member Type <br /> Uniform psf Roof(125%) 20 20 0 24" Roof Joist <br /> NOTES <br /> •Building code and design methodology: 2018 IBC ASD(US). <br /> •Product Acceptance: ICC-ES ESR-2994 and LABC/LARC Supplement. <br /> •Continuous lateral support required at top edge. Lateral support at bottom edge shall be per RedBuilt recommendations. <br /> P:\201822-Jacob Davis\01- Everett\002-Spec TI\Agency\Permit Set\Harvey TI-Red-I90.red <br /> 3/4/2021 9:05:52 AM Project : Folder:Type .43age-.1.e44. <br /> The products noted are intended for interior, untreated,non-corrosive applications with normal temperatures and dry conditions of use,and must be 5 <br /> installed in accordance with local building code requirements and RedBuiltT" recommendations.The loads,spans,and spacing have been provided by <br /> others and must be approved for the specific application by the design professional for the project. Unless otherwise noted,this output has not been <br /> - reviewed by a RedBuilt"associate. PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> RedBuilt", RedSpec", Red-I", Red-I45", Red Red-I58", Red-I65", Red-I90"^, Red-I90H", Re HS"", Red-LT"', Red-WT"', Red-ST"', Red-M" <br /> Red-H"", RedLam"", FloorChoiceT"' are trademar RedBuilt LLC, Boise ID, USA. Copyright©2010-202 Built LLC.All rights reserved. <br />