Laserfiche WebLink
• • <br /> MULHERN KULP <br /> RESIDENTIAL STRUCTURAL ENG'NEERING <br /> 300 Brookside Avenue,Building 4,Ambler,PA 19002►p 215-646-8001 ►mulhernkulp.com <br /> July 28,2020 <br /> Alex Scofield <br /> YEN DESIGN INC. <br /> 17191 Bothwell Way NE.#B104 <br /> Lake Forest Park,WA 98155 <br /> 2101 Lexington Ave <br /> Everett,WA <br /> PLAN REVIEW COMMENTS <br /> M+K Project#: 251-20006 <br /> Reference <br /> Structural Plans,designed by Mu/here&Ku/p <br /> Plan Review Comments,dated 7/02/2020 <br /> Alex: <br /> Pursuant to your request,we are providing this letter to address the structural items resulting from the above referenced plan review <br /> comments for the above referenced townhomes in the City of Everett,WA.Below,please find the review comment,followed by our <br /> response. <br /> PLAN REVIEW COMMENTS <br /> ■ Comment 1:The General Structural Notes on sheets 1.0 states that the design was performed to the IRC However,it appears <br /> the structural design has been performed to the IBC and the AWCNDS-15, The 2015 IBC should be referenced in the notes. See <br /> IRC Section 30113. <br /> Response: This is a residential structure designed under the IRC.The lateral design is a component of the design that was <br /> engineered,as permitted by section 301.1.3.Please see the updated notes for clarification. <br /> ■ Comment 3:The vertical load path for the proposed roof includes supportbythe existing structure on the west side, Details for <br /> the proposed connections,including modifications to the interior wall covering to instal/blocking,should be included in the <br /> construction drawings Calculations substantiating the connections should be submitted for review, See IRC Section 106.11 and <br /> IBC Section 10721. <br /> Response: Modifications to the interior wall covering to instal blocking shal be made under the discretion of the builder or <br /> architect.The worst case vertical loading of a post that is fastened back to the existing structure is approximately 2.2 kips.As <br /> speared by the structural plans,the covered porch posts adjacent to the existing structure are to be fastened to the existing <br /> structure with(1)Y4"x6"SDS screw @ 12"o.c.Assuming an 8 foot plate height,a minimum of 9 screws shall be utilized in the <br /> connection,which has a capacity of 2.5 kips.This translates to approximately 275 lb per screw.A note has been added to the <br /> plan to clarify that the 2x blocking shall be fastened to adjacent studs w/(3).131"x3"long toenais at each side,which has the <br /> capacity to transfer the load back into the wall studs,as required.Therefore,the connections are sufficient in transferring any <br /> vertical load from the covered patio addition to the existing wall and into the existing foundation below. <br />