i <br /> Yen Design Inc.—2101 LexiigtanAve <br /> Plan Review Comments <br /> 7-28-2020 <br /> ■ Comment 4. The lateral load path for the roof structure is not dear The east side appears intended to act as a cantilever column <br /> system for the north south loading. However,the west side and the east-west direction appear to rely on the existing structure <br /> for lateral support. The structure should be designed for lateral support per Section 12.8and 12 Z3. Calculations substantiating <br /> the load path should be submitted for review The existing structure should be evaluated per/EBC Section 1103,3.See IBC <br /> Sections 1014.7and 1613.1 <br /> Response: As stated in comment 3,each exterior post adjacent to the existing structure has a minimum of 9 screws fastened <br /> back to the existing structure,which has a total withdraw capacity of about 3.6 kips.The maximum lateral load that the covered <br /> porch experiences is 1.4 kips in either direction(north-south or east-west).Idealizing the corrugated panels as a rigid roof <br /> diaphragm,half of the lateral load,or 0.7 kips,will be resisted by the west side of the diaphragm in the north-south direction. <br /> Because there are 3 posts on the west side of the covered roof fastened back to the existing structure,the existing structure is <br /> required to resist 0.23 kips of load at each location where the exterior posts are fastened.Therefore,the 9 screws are adequate <br /> in transferring lateral load into the existing structure in each direction.It is our professional opinion that,by inspection,the <br /> existing structure is able to resist any additional lateral load imposed on it by the new covered patio given such low values. <br /> • Comment 5:The 2x10 rafters bear on the 4x8 beams along the east edge of the proposed structure.Connection do not appear <br /> to be provided. Connections should be specified providing adequate strength for both lateral load transfer and resistance to <br /> uplift. Calculations substantiating the connection design should be submitted for review. <br /> Response: Please see the revised notes for typical connection between the roof rafters and covered porch beams.Typical <br /> connections,which consist of(2)SDWC1500 toescrews,are adequate for both lateral and uplift forces.The withdrawal capacity of <br /> the typical connection is approximately 270 lbs,and the shear capacity of the typical connection is approximately 340 lbs. <br /> • Comment 6:The roof framing does not appear to be provided with adequate weather protection to prevent exposure and <br /> deterioration,notably around the perimeter. The project should speciy Bashing around the per/meter,or alternativey the use of <br /> preservative-treated or naturally-durable wood Cut ends of wood members should be coated with a preservative treatment <br /> comply with AINPAM4. See IRC Sections R3171.1 and R903 <br /> Response: Roof framing has been revised to show pressure treated wood.Please see updated structural plans and beam <br /> calculations. <br /> Please feel free to call if you have any questions. <br /> t3�S OV w�r3 <br /> Respectfully, AtY C <br /> col <br /> MULHERN & KULP STRUCTURAL ENGINEERING, INC. ' <br /> f- ! `- y� <br /> Warren Chan Project Engineer <br /> q <br /> ' 1547$ 4 <br /> A <br /> Nicholas 1 Martignetti,P.E. Project Manager 9.0 40rsrP $ <br /> 410NAL <br /> e Seal&i, <br /> 2 <br />