My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2101 LEXINGTON AVE 2021-09-24
>
Address Records
>
LEXINGTON AVE
>
2101
>
2101 LEXINGTON AVE 2021-09-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2021 10:49:59 AM
Creation date
9/24/2021 10:49:45 AM
Metadata
Fields
Template:
Address Document
Street Name
LEXINGTON AVE
Street Number
2101
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Design <br /> PC Comment Response Letter <br /> July 30, 2020 <br /> Subject: PC Comment Response Letter <br /> Permit No: B2005-042 <br /> Address: 2101 Lexington Ave <br /> Everett, WA <br /> To: City of Everett <br /> The following comments are in response to a correction letter written by: <br /> Reviewer Name: Drew Martin <br /> Reviewer Phone: 425-257-8813 <br /> 1. (Structural, separate letter) <br /> 2. The construction of the proposed structure is not clear. A sketch is included <br /> in the structural calculations providing an incomplete section through the roof <br /> and house. A section should be included in the construction drawings <br /> showing the required construction. The section should include the <br /> elevation(s) and slope for the roof. The location of the east posts should also <br /> be dimensioned. The east side of the structure shall comply with the fire- <br /> resistance construction requirements of IRC Section R302. See IRC Section <br /> 106.1.1, and IBC Sections 107.2.1 and 1603.1. <br /> a. Response: Section provided on sheet A4.1. <br /> 3. (Structural, separate letter) <br /> 4. (Structural, separate letter) <br /> 5. (Structural, separate letter) <br /> 6. The roof framing does not appear to be provided with adequate weather <br /> protection to prevent exposure and deterioration, notably around the <br /> perimeter. The project should specify flashing around the perimeter, or <br /> alternatively the use of preservative-treated or naturally-durable wood. Cut <br /> ends of wood members should be coated with a preservative treatment <br /> comply with AWPA M4. See IRC Sections R317.1.1 and R903 <br /> a. Response: Pressure treated wood now specified. <br /> (206)432-11111 WWW.YENDES.COM t 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.