Firefox <br />about:blank <br />Option I. Dispersion Design Worksheet <br />*This BMP can only be used for roof runoff per the SWMMWW* <br />• Roof area requiring mitigation (W); ,. 4 __ <br />Minimum 50 ft flow path provided:. I Yes -I- No <br />Dispersion systems with 25-50 ft flow path must be modeled using a continuous runoff model to <br />confirm project meets the flow control requirements, attach modeling results to this worksheet. <br />Dispersion is not allowed where less than 25 ft flow path can be achieved and another BMP shall <br />be used to meet the flow control requirement. <br />• Number of splashblock downspout dispersions: and/or Downspout dispersion <br />trenches 1¢a (Minimum of two-50 it long downspout dispersions and one per 350 sf of roof <br />area, is required to meet the Flow control requirement using this worksheet) <br />,Downspout Dispersion areas do not overlap. <br />One of the following must be met for the dispersion area(s), check one: <br />The vegetated flow path consists of well -established lawn or pasture, landscaping with <br />well -established groundcover, native vegetation with natural groundcover, or an area that meets <br />BMP T5.13: Post -Construction Soil Quality and Depth. The groundcover is dense enough to help <br />dis ere and infiltrate flows and to prevent erosion. <br />BMP T5.13 Post -Construction Soil Quality and Depth is being provided for dispersion areas <br />(area to be shown on project plans) <br />The following design criteria shall be met (check each to confirm the requirement has <br />been met): <br />I. Maintain a setback of at least 5 feet between any edge of the trench and any structure or property line. <br />x <br />2. Setback requirements in Section 4-4.1 (3) of the DCSS have been met <br />Including: <br />• 50 feet setback from slopes greater than 15 percent and greater than 10 feet in height <br />3. Maintain a vegetated flow path of at least 50 feet between the discharge point and any property line, <br />structure, slope steeper than 15%, stream, wetland, lake, or other impervious surface. Sensitive area <br />buffers may count toward flow path lengths. , , X <br />4. A maximum of 350 square feet of roof area may drain to each splashblock or dispersion trench. yC <br />S. Place a splashblock or a pad of crushed rock (2 feet wide by 3 feet long by 6 inches deep) at each <br />downspout discharge point i <br />City of Everett Public WoAs <br />Small Project Stormwater Site Plan Report for Projects in <br />the Combined Sewer Area -April 2021 <br />°F 15 of 23 7 <br />6/8/2021, 10:18 AM <br />