My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ll <br />PURL/C WOl K.9 <br />April 17, 2018 <br />Mark Thunberg <br />Facilities Director <br />Snohomish County Property Management <br />3000 Rockefeller Ave, M/S 404 <br />Everett, WA 98201 <br />mark.thunberg@co.snohomish.wa.us <br />Owner: Snohomish County <br />Job Address: 3000 Rockefeller Ave <br />Plan Check No: BW1802-011 <br />RE: Building Permit Review Letter <br />Dear Mr. Thunberg, <br />In response to the application for a building permit, the plans have been examined and you are <br />advised that revisions may be necessary before a permit can be issued. Please review and <br />respond to the comments below. <br />NON-STRUCTURAL <br />General <br />1) This review is based on the 90% submittal set — the 100% set has not yet been received. <br />2) There is proposed work occurring to the Inmate Holding areas on several floors within the <br />existing building. Code sheet GI-104 classifies this I-3 Occupancy as accessory to the <br />Group B Occupancy with no fire -resistive separations required. As Section 508.2.1 still <br />requires all other provisions pertaining to the I-3 Occupancy to be complied with (other <br />than separations, building height and allowable area) — please provide a narrative of how <br />the provisions of Section 408 are satisfied. <br />3) Electric vehicle charging infrastructure should be provided in accordance with Section 427. <br />4) It should be clarified if the existing building is currently provided with an emergency <br />voice/alarm communication system as specified in Section 907.2.1.1. <br />5) Wainscoting should be shown for the toilet rooms in elevations 17 & 18 on Sheet IQ-201. <br />Section 1210.2.2 <br />Construction <br />
The URL can be used to link to this page
Your browser does not support the video tag.