My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Snohomish County Courthouse Renovation (Date 5/11/2018 <br /> fi The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> C405.2.5- Hotel/motel guest Indicate method of automatic control-vacancy or captive key <br /> NA Item 3 rooms control of all installed luminaires and switched receptacles in <br /> _guest room <br /> C405.2.5- Supplemental task Indicate method and location of automatic shut-off vacancy <br /> Yes Item 4 lighting control for supplemental task lighting,including under-shelf or E-3XX series <br /> under-cabinet lighting <br /> Indicate on plans eligible non-visual lighting applications, <br /> include sq.ft.area of each lighting control zone; <br /> C405.2.5- Lighting for non- Indicate on plans that non-visual lighting are controlled <br /> NA <br /> Item 5 visual applications independently from both general area lighting and other lighting <br /> applications within the same space; <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Indicate on plans that lighting equipment for sale or <br /> Lighting equipment demonstration are controlled independently from both general <br /> NA C405.2.5- for sale or area lighting and other lighting applications within the same <br /> Item 6 demonstration space; <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Identify on plans egress fixtures that function as both normal E-3XX series and <br /> and emergency means of egress illumination; E-9XX series <br /> Provide calculation of lighting power density of total egress NA <br /> lighting; <br /> Yes C405.2.5- Means of egress <br /> If total egress lighting power density is greater than 0.02 W/sq. <br /> Item 7 lighting E-3XX series and <br /> ft.,indicate on plans egress fixtures requiring automatic shut-off E-9XX series <br /> during unoccupied periods; <br /> III Indicate method of automatic shut-off control E-3XX series and <br /> E-9XX series <br /> Indicate on exterior lighting plans and fixture schedules the E-3XX series and <br /> automatic lighting control method,control sequence,and E-9XX series <br /> locations served; <br /> For building façade and landscape lighting,indicate automatic E-3XX series and <br /> Exterior lighting controls shut off lighting as a function of dawn/dusk and fixed E-9XX series <br /> Yes C405.2.7 controls opening/closing time; <br /> For all other exierior lighting,indicate automatic controls shut <br /> off lighting as a function of available daylight;include control E-3XX series and <br /> sequence that also reduces lighting power by at least 30% E-9XX series <br /> between 12am-6am,or from 1 hour after closing to 1 hour <br /> before opening,or based upon motion sensor <br /> Exterior building For building grounds fixtures greater than 100 watts,indicate <br /> Yes C405.5.1 grounds lighting on plans whether fixtures have efficacy greater than 80 lumens E-3XX series and <br /> controls or;are controlled by motion sensor,or are exempt lighting per E-9XX series <br /> C405.5.2 <br /> Area controls- Indicate location(s)of master control switch(es)intended to <br /> Master control control multiple independent switches;circuit breaker may not E-3XX series <br /> Yes C405.2.5 be used as a master control switch; <br /> switches and circuit <br /> power limit Verify that no 20 amp circuit controlled by a single switch or Yes <br /> automatic control is loaded beyond 80% <br /> To comply with additional efficiency package option,indicate on <br /> plans all interior lighting fixtures that are individually addressed <br /> and provided with continuous dimming,or exception taken; <br /> NA C406.4 Enhanced digital <br /> lighting controls Include calculation of percent total installed interior lighting <br /> power that is configured with required enhanced lighting control <br /> functions(min 90%to comply with additional efficiency <br /> package option) <br /> If claiming lighting system commissioning exemption provide <br /> IIIsupporting calculation; <br />
The URL can be used to link to this page
Your browser does not support the video tag.