My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Mark Thunberg <br />Snohomish County Property Management <br />Plan Check Number: B1802-011, First Review (Structural) <br />June 18, 2018 <br />27. The building has reentrant corners at all levels (i.e., Sheets S-202 through S-206) resulting in a <br />Type 2 horizontal structural irregularity per ASCE 7-10 Table 12.3-1. The design forces for the <br />diaphragm connections to the shear walls and collectors, and the collectors and their <br />connections to the shear walls, shall be increased 25%. Calculations verifying the design <br />considering the increased loading shall be submitted for review. See IBC Section 1613.1 and <br />ASCE 7-10 Section 12.3.3.4. <br />28. The building has a reentrant corner at Grid F'/12.1 at all levels (i.e., Sheets S-202 through S- <br />206). The chord for the addition's diaphragms along Grid 12.1 should be developed into the <br />existing structure. Calculations substantiating the chord development should be submitted for <br />review. See IBC Section 1613.1 and ASCE 7-10 Section 12.10.1. <br />29. The concrete shear wall on Grid C/8-10.5 is discontinuous at the existing concrete -topped steel <br />decks per Details 9, 10, 14, 15, 19, and 20 on Sheet S-601. The wall changes thickness from <br />16 to 10 inches over its height. Elevation 6/S-301 indicates coupling beams are bisected by <br />the existing decks. The following comments should be addressed: <br />a. The shear strength of the shear wall at the decks should be substantiated per the shear - <br />friction criteria of ACI 318-14 Section 22.9.3 with µ=0.7k per Table 22.9.4.2. See IBC <br />Section 1901.2. <br />b. Detail 11/S-311 does not appear to represent the conditions for the coupling beams. A <br />detail representing the conditions should be included, indicating the installation of the shear <br />reinforcement and accounting for the changes in the wall thickness. <br />30. The structural calculations do not appear to include a design for the addition diaphragms. <br />Calculations substantiating the design, including load transfer to the shear walls, shall be <br />submitted for review. The connection loads to the shear walls and collectors shall be increased <br />per ASCE 7-10 Section 12.3.3.4. See IBC Section 1604.1 and 1613.1. <br />31. Calculations shall be submitted for review substantiating the design of the collectors for the <br />addition. Collectors appear to be provided on Sheets S-202 through S-206 on Grid 12.1. <br />Verify if collectors are required at other locations, including but not limited to Grids F, G, K, and <br />16.1. Calculations shall include the connections between the collectors and the diaphragms <br />and shear walls. The collectors and connections shall include the load increases per ASCE 7-10 <br />Sections 12.3.3.4 and 12.10.2.1. See IBC Sections 1604.1 and 1613.1. <br />32. Calculations shall be submitted for review substantiating the design of the collectors between <br />the existing structure and the new shear walls. Collectors are provided on Sheets S-201 <br />through S-206 on Grids C/5-15, F/5-21, 16.1/E-F, and 19.1/E-F. Calculations shall include the <br />connections between the collectors and the diaphragms and shear walls. Note that Details <br />12/5-601 and 9/S-602 appear designed to transfer tension only; the calculations shall clarify <br />the transfer of compression loads. The collectors and connections shall include the load <br />increases per ASCE 7-10 Sections 12.3.3.4 and 12.10.2.1. See IBC Section 1604.1 and 1613.1. <br />Page 8 of <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 . (425) 257-8810 • Fax (425) 257-8857 <br />
The URL can be used to link to this page
Your browser does not support the video tag.