My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9 <br />• <br />June 28, 2018 <br />Mr. Tony Lee <br />Snohomish County Courthouse Renovation/Addition <br />age 2 <br />NON-STRUCTURAL <br />General <br />4) Approval pending confirmation with fire marshal's office. <br />Response: Comment acknowledged. CBRE Heery spoke with Jim Venturo, Assistant Fire <br />Marshal, to obtain additional information regarding this comment. Jim acknowledged that <br />only renovated areas need to be upgraded at this time to the new fire alarm system. Jim <br />also indicated that the County should develop a timeline for upgrading the remaining <br />areas in the existing building. <br />Construction <br />4) If the steel columns in Details 2 & 18 on Sheet A-502 and 12, 14, & 15 on Sheet A-503 <br />are part of the structural frame, they should be shown with individual fire -protection. <br />Response: Detail on sheetA-502 was revised in Addendum No. 2 in response to the original <br />comment (copy attached). Detail 18 on sheet A-502 is not part of the building's structural <br />frame. It is for a screen wall on/above the roof. Details 12 & 13 on sheetA-503 have been <br />revised and issued as ASI No. 1. Detail 15 on sheet A-503 was revised in Addendum No. 2 in <br />response to the original comment. Sheets A-502 & A-503 have had additional "2-HR" notations <br />added to other steel column fireproofing plan details on these sheets. The details have been <br />revised and are attached to this response letter as ASI No. 1. <br />5) If the column on Detail 9 on sheet A-503 is part of the structural frame, the entire column <br />should be wrapped (even within the GWB wall). <br />Response: This detail has been revised to show a complete column wrap and is attached <br />to this response letter as ASI No. 1. <br />6) The fire -resistive listing should be shown on partition Type Non Sheet 1-321(no change <br />from original comment). <br />Response: The UL assembly number was added to partition Type N and was issued as part <br />of Addendum 2, which was to be included with the original response letter. Refer to <br />attached copy. <br />12)Two-hour shaft listingAER-09038 should be included on the plans and referenced on <br />Detail 5/1-417. <br />Response: Detail 511-417 has been revised and is attached to this response letter as ASI <br />No. 1. <br />
The URL can be used to link to this page
Your browser does not support the video tag.