616 PECKS DR 2021 Plans 2022-11-29
>
Address Records
>
PECKS DR
>
616
>
Plans
>
616 PECKS DR 2021 Plans 2022-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2022 1:06:28 PM
Creation date
10/19/2021 10:32:58 AM
Metadata
Fields
Template:
Address Document
Street Name
PECKS DR
Street Number
616
Permit
B2105-023
Year
2021
Notes
New 887sf portable P1, landing, and ramp to be installed
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HP-1 <br />TCURBF <br />SUPPLY PLENUM <br />#PWS131 <br />OCCUPIED SET POINT <br />TO BE CONTROLLED <br />BY nLIGHT OCCUPANC <br />SENSORS <br />,�M--E-�C-�HIIAN�"1-,CAILI-��,�,��P-LAN <br />MINIMUM VENTILATION RATES Oj 40 <br />Az = room area (sf) <br />®cc, Dens = occupant density (from Table 403.3) <br />Pz (calc) = zone population or occupant quantity (calculated) <br />Pz (used) = zone population or occupant quantity (user can override the calculation -increase only) <br />Rp = people outdoor airflow rate in breathing zone (cfm/person) <br />Ra = area outdoor airflow rate in breathing zone (cfm/sf) <br />Vbz = Breathing zone outdoor ai r flow rate per ea. 4-1( Rp*Pz+Ra*Az) <br />COMP <br />TOTAL <br />ECON. <br />DOAS <br />BARD <br />TYPE <br />CFM <br />BLR. <br />100% <br />ERV <br />TAG <br />QTY <br />MODEL # <br />TONS <br />SCROLL <br />NOM. <br />TYPE. <br />FREEFLOW <br />OSA <br />VENTIL' <br />PART/FULL <br />HP-1 <br />1 <br />C36HA-A10ZP4XXR <br />3 <br />2-STAGE <br />750 <br />ECM <br />NO <br />488 <br />1100 <br />ADDITIONAL REMARKS; <br />1 ENERGY MODEL PLAN APPROVAL #15FBS1700193 <br />2 - INCLUDE BARD WALL CURB '#TCURBF3642A-4. <br />3 - THERMOSTAT, BARD#8403-060, 7-DAY PROGRAMMABLE <br />4 - WALL CO2 SENSOR. #8403-067 <br />5 - OCCUPANCY SENSOR, (SUPPLIED BY BLAZER) <br />6 - GPS (FIELD INSTALLED CONTROL KIT). <br />7 - 2" FILTER. <br />8 - ERV (DOAS) ENERGY RECOVERY. <br />9 - UNIT COLOR IS *BUCKEYE GRAY* <br />10 - PRE INSTALLED OUTDOOR THERMOSTAT, SET AT 40DEG'S. <br />** M.C. TO REFER TO INSTALLATION INSTRUCTIONS FOR START UP AND EQUIPMENT SET. <br />** M.C. TO CHECK SITE VOLTAGE AND SET CORRECT TAP ON TRANSFORMER. <br />k* M.C. TO SET AND PROGRAM THERMOSTAT PER CUSTOMERS REQUIREMENTS. <br />DATE q RE6i al®N <br />DOAS/ERV/ELECTRICAL (1) DOAS/ERV/ELECTRICAL <br />LOW VENTILATION MODE FULL VENTILATION MODE <br />ECM ECM <br />V-PH ERV BLOWER V-PH ERV BLOWER <br />MOTOR MOTOR <br />230/1 AMPS-1.3 AMPS_ N 230/1 AMPS-2.2 AMPS-1.74 <br />WATTS-296 WATTS-95 WATTS-497 WATTS-192 <br />MECHANICAL NOT : <br />1. DUCT MATERIAL IS 26 GA. GALV. AND FLEX DUCT. DUCTWORK SHALL BE SUPPORTED PER 2015 IMC <br />WAC CHAPTER 6, SECTION 603 <br />2. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25, SMOKE DEVELOPMENT <br />OF 50 PER 2015 IMC WAC CHAPTER 6. SECTION 602 <br />3. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND <br />CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND SEALED WITH <br />WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC -PLUS EMBEDDED -FABRIC SYSTEMS OR APPROVED TAPES <br />INSTALLED IN ACCORDANCE WITH 2O15 IMC WAC CHAPTER 6 SECTION 603.9. <br />4. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEN THEY SHALL COMPLY <br />WITH IMC CHAPTER 6 <br />5. 10" DIFFUSERS WITH NO MANUAL DAMPERS. USE FLOW CONTROLS AT WYES, TYPICAL AS NOTED ON PLAN <br />6. MINIMUM OUTSIDE AIR VENTILATION PER 2015 IMC WAC CHAPTER 4, TABLE 403.3.1.1. <br />7. OUTSIDE AIR DAMPERS SHALL COMPLY WITH 2O15 WSEC, SECTION C403.2.4.3. <br />8. SINGLE PACKAGE UNITARY FAN COOLING UNITS HAVING A TOTAL COOLING CAPACITY OF GREATER THAN <br />20,000 Btu/h REQUIRE ECONOMIZERS PER WSEC 403.3. EXCEPT AS PERMITTED BY C403.3 EXCEPTION 1 <br />LAEQHANI1CAL NOTES: (cont.) <br />MECHANICAL EQUIPMENT INSTALLATION IN OR ON THIS BUILDING SHALL BE IN ACCORDANCE WITH <br />THE REQUIREMENTS OF THE 2015 IMC WAC CHAPTER 6. <br />ROUND FLEX DUCT SHALL BE U.L. LISTED CLASS 1, STANDARD 181 - FACTORY MADE AIR DUCTS AND AIR <br />CONNECTORS. MEASURED IN ACCORDANCE TO ASTM C 518 OR ASTM C 177 AT 75DEG F MEAN <br />TEMPERATURE. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURES INSTALLATION INSTRUCTIONS <br />MECHANICAL DRAWINGS SHOW DUCTWORK SIZES TO BE CLEAR INSIDE DIMENSION. <br />DUCT INSULATION SHALL COMPLY WITH 2O15 IMC WAC CHAPTER 6, SEC. 604. <br />ELECTRICIAN MUST VERIFY ALL ELECTRICAL REQUIREMENTS AND LOCATIONS. <br />THERMOSTAT SCHEDULING TO BE PERFORMED ON SITE BY OTHERS. <br />ALL HVAC EQUIPMENT LEAVES FACTORY WIRED FOR 240 VOLT OPERATION <br />THE ACCEPTABLE OPERATING RANGE FOR THE 240V & 208V TAPS ARE: <br />TAP RANGE <br />240 253-216 <br />208 220-187 <br />SITE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THE RIGHT TAP IS CONNECTED FOR <br />THE APPLIED SITE VOLTAGE. <br />AIR FILTERS IN HVAC UNITS OR SYSTEMS ARE TO BE CHANGED EVERY 30 DAYS BY OTHERS ON SITE, <br />REGISTER AIR FLOW TEST AND BALANCE OF HVAC SYSTEM TO BE PROVIDED AND PERFORMED BY OTHERS ON SITE. <br />HVAC SITE CONTRACTOR IS RESPONSIBLE FOR BALANCING THE SYSTEM. (2015 IMC WAC 403.3.3.1.5) <br />DEALER AP"PROVAL <br />❑ APPROVES <br />AR"'. <br />❑ APPROVE® EXCEPT AS NOTED D DREELINIVII I <br />❑ REVISE AS NOTE® AND RESUBMT NOT FOR CONSTRUCTION <br />APPROVE® By Data <br />COOLING CAPACITY 3❑ <br />HEATING CAPACITY <br />® <br />DOAS <br />ENERGY RECOVERY <br />COOL <br />SENS. <br />COOL <br />SENS. <br />HTG <br />HTG <br />OUTDOOR <br />OUTSIDE <br />ENT <br />ENT <br />CAP. <br />CAP. <br />CAP. <br />CAP. <br />OUTSIDE <br />CAP. <br />CAP. <br />SUMMER <br />DB/WB <br />HRS <br />HRL <br />WINTER <br />INDOOR <br />DB <br />DB <br />WB <br />EER <br />IPLV <br />BTUH <br />BTUH <br />BTUH <br />BTUH <br />DB <br />COP <br />BTUH <br />BTUH <br />EFFICIENT <br />DEG'S <br />BTUH <br />BTUH <br />EFFICIENT <br />DB <br />PART LOAD <br />PART LOAD <br />FULL LOAD <br />FULL LOAD <br />PART/LOAD <br />FULL/LOAD <br />UNIT <br />ELECT. IN <br />HEAT STRIPS <br />ELEC. ELEC. OPER. <br />WHIR HEAT HEAT WGT. ADDITIONAL <br />MOP V-PH MCA MOP CKT V-PH MCA BTUH CKT KW BTUH LES. REMARKS <br />95 80 67 11.0 14.5 23.4K 18.5K 35K 26.3K 47 3.3 22.7K 31K 65% 95/70 6,318 1,711 80% 1,711 1 23,3281230/11 27 I 40 1 A 1240/11 52 1 60 1 B 1 10 134,1301 678 1 1, 2, 3, 4, 5, 6, 7, 8 <br />C36H1 <br />ERV Watts - Low <br />296 Watts <br />Blower Full Load <br />192 Watts <br />ERV Amps - Low <br />1.3 Amps <br />Blower Full Load <br />1.74 Amps <br />ERV CFM - Low <br />300 CFM <br />Blower Part Load <br />95 Watts <br />ERV Watts - Med <br />415 Watts <br />Blower Part Load <br />0.87 Amps <br />ERV Amps - Med <br />1.8 Amps <br />ERV CFM - Med <br />375 CFM <br />Compressor Full <br />2588 Watts <br />ERV Watts - Hi <br />497 Watts <br />Compressor Full <br />11.46 Amps <br />ERV Amps - Hi <br />2.2 Amps <br />Compressor Part <br />1734 Watts <br />ERV CFM - Hi <br />450 CFM <br />Compressor Part <br />7.99 Amps <br />Outdoor Fan <br />380 Watts <br />Outdoor Fan <br />1.67 Amps <br />COPYRIGHT 2018, BLAZER INDUSTRIES, INC. <br />THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br />OF BLAZER INDUSTRIES, INC. AND SHALL <br />NOT BE REPRODUCED, USED, OR DISCLOSED <br />TO OTHERS EXCEPT AS AUTHORIZED BY THE <br />WRITTEN PERMISSION OF BLAZER INDUSTRIES <br />IBM <br />qtQ3V__ <br />6___6wU. <br />��of ._ - _ ..,N....... <br />oCrn. <br />EE *97325-0489 <br />- <br />Approved <br />, <br />Drawn .- �x <br />�_ <br />