My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
616 PECKS DR 2021 Plans 2022-11-29
>
Address Records
>
PECKS DR
>
616
>
Plans
>
616 PECKS DR 2021 Plans 2022-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2022 1:06:28 PM
Creation date
10/19/2021 10:32:58 AM
Metadata
Fields
Template:
Address Document
Street Name
PECKS DR
Street Number
616
Permit
B2105-023
Year
2021
Notes
New 887sf portable P1, landing, and ramp to be installed
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />nPP16 <br />PACK TO <br />THERM <br />OCCUPIED f <br />14 <br />.ELECTRICAL <br />RI ` <br />• A' <br />H.V.A. <br />t <br />I OPERATION <br />O' VOLTAGE <br />[ <br />I <br />COMPRESSOR <br />OUTDOOR <br />INDOOR BLOWER <br />MINIMUM CIRCUIT AMPS <br />«AMPS <br />MAXIMUM OVERCURRENT PROTECTION <br />80 <br />AMPS <br />OVERCURRENT PROTECTION— <br />OR , CIRCUIT BREAKER <br />Y <br />NOTE: ALL DEVICES &FACE <br />PLATES TO BE IVORY <br />GENERAL NOTES: <br />1. WHEN STRANDED WIRE IS USED, ALL TERMINATIONS ARE MADE BY <br />A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID CONDUCTORS <br />OR OTHER APPROVED MEANS OF TERMINATION. <br />2. ALL CONDUCTORS ARE COPPER; TYPE THHN / THWN <br />3. RATING OF STANDARD PANEL IS 22,000 A.I.C. <br />4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE. <br />5. HVAC DISCONNECTS SHALL BE LABELED WITH AN IDENTIFICATION <br />PLATE SHOWING CIRCUIT NUMBER AND EQUIPMENT SERVED. <br />WAC 296-46B-1 10 022 <br />6. EXTERIOR WEATHER PROOF GFCI SHALL HAVE A "HEAVY DUTY' <br />WEATHER PROOF "IN USE' COVER. 2014 NEC 406.9(B) (1) <br />7. CONTROLLED RECEPTACLES SHALL BE LABELED PER 2014 NEC <br />406.3(E) WITH THE TEXT "CONTROLLED" AND THIS SYMBOL � <br />8. THIS PLAN IS NOT AN "AS -BUILT' CIRCUITS MAY BE RUN DIFFERENT <br />THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. <br />, <br />1. ALL LIGHTING SHALL CONFORM TO SECTION C405 <br />2. BASE CLASSROOM LIGHTING POWER DENSITY (C405.4.2.1) <br />833 SQ. FT. x l WATT PER SQUARE FOOT = 833 WATTS ALLOWED <br />ADDITIONAL REDUCTION IN LIGHTING POWER DENSITY (C406.3.1) <br />833 WATTS ALLOWED (BASE) x .75 = 625 WATTS ALLOWED <br />TOTAL WATTS ALLOWED = 625 <br />TOTAL WATTS INSTALLED = 477 WATTS <br />% OF ALLOWED INSTALLED = 76% <br />3. 100% OF LIGHTING FIXTURES HAVE EMBEDDED OCCUPANCY AND <br />DAYLIGHT SENSORS FOR INCREASED ENERGY SAVINGS, AND ARE <br />INDIVIDUALLY ADDRESSABLE. (C406.4) <br />4. 100% OF LIGHTING IS SET FOR CONTINUOUS DIMMING AND IS <br />ADJUSTABLE BY OCCUPANTS, FOR OCCUPANT COMFORT, VIA <br />WALL PODS. (C406.4) <br />5. 50% OF RECEPTACLES ARE CONTROLLED BY LOCAL OCCUPANCY <br />SENSORS (C405.10) <br />6. THERMOSTAT OCCUPIED PERIOD WILL BE DETERMINED BY THE <br />nLIGHT OCCUPANCY SENSORS INTEGRAL TO THE LIGHTING <br />FIXTURES. <br />ELECTRICAL PLAN REVIEW <br />I W <br />LOAD CALCULATIONS <br />VOLTAGE: <br />120/240 <br />PHASE: <br />1 � <br />CONNECTED LOAD <br />CALL. LOAD <br />LIGHTING <br />EXTERIOR <br />75 VA <br />x <br />125 <br />% = <br />94 VA <br />INTERIOR <br />477 VA <br />x <br />125 <br />% = <br />596 VA <br />RECEPTACLES <br />THRU 10,000 <br />3240 VA <br />x <br />100 <br />% = <br />3240 VA <br />OVER 10,000 <br />0 VA <br />x <br />50 <br />% = <br />0 VA <br />MOTORS, COMPR. <br />TOTAL <br />4104 VA <br />x <br />100 <br />% = <br />4104 VA <br />LARGEST <br />(2632) VA <br />x <br />25 <br />% = <br />708 VA <br />HEATING <br />10000 VA <br />x <br />100 <br />% = <br />10000 VA <br />TOTAL KVA <br />17.90 <br />TOTAL <br />KVA <br />18.74 <br />CONNECTED <br />CALCULATED <br />LOAD AMPS <br />74.57 <br />LOAD <br />AMPS <br />78.09 <br />COPYRIGHTi iINDUSTRIES, 911 1 <br />11 <br />THIS MATERIAL PROPERTY <br />i -' R `�� � Classroom t <br />OF BLAZER INDUSTRIES, INC, AND SHALL Ell <br />INS 5W. BE REPRODUCED, DISCLOSED j 'Stock <br />. _ <br />TO OTHERS EXCEPT AS AUTHORIZED BY THE <br />ONE-UNE-D�AGRA <br />100 AMP FEEDER PANEL <br />MAIN BREAKER <br />120/240 1� <br />100 AMP <br />1/2" PVC 1-1/2" PVC STUB THRU <br />STUB FOR BY BLAZER <br />FUTURE (2) #2 Cu THHN <br />GROUNDING (1) #4 Cu THHN <br />AND (1) #6 Cu <br />BONDING (WIRE ON SITE BY OTHERS) <br />SCHEDULEPANEL <br />NOTE: ALL CONDUCTORS COPPER. <br />100 AMID 10 22,000 AIC <br />CKT <br />DESCRIPTION <br />TRIP <br />WIRE <br />VOLT <br />100 <br />VOLT <br />WIRE <br />TRIP <br />DESCRIPTION <br />CKT <br />A <br />NO. <br />AMPS <br />SIZE <br />AMPS <br />B <br />�� <br />— <br />AMPS <br />SIZE <br />AMPS <br />NO. <br />1 <br />LIGHTS <br />20 <br />12 <br />552 <br />—�\ <br />7052 <br />4 <br />s0 <br />HVAC <br />2 <br />3 <br />RECEPTACLES <br />20 <br />12 <br />1260 <br />7052 <br />/ <br />/ <br />f <br />4 <br />5 <br />RECEPTACLES <br />20 <br />12 <br />1060 <br />- <br />- <br />- <br />SPACE <br />6 <br />7 <br />RECEPTACLES <br />20 <br />12 <br />900 <br />- <br />- <br />- <br />SPACE <br />g <br />9 <br />SPACE <br />- <br />- <br />- <br />- <br />- <br />- <br />SPACE <br />10 <br />11 <br />SPACE <br />- <br />- <br />- <br />- <br />-- <br />SPACE <br />12 <br />13 <br />SPACE <br />- <br />- <br />- <br />- <br />_. <br />- <br />SPACE <br />14 <br />15 <br />SPACE <br />- <br />- <br />- <br />- <br />- <br />- <br />SPACE <br />16 <br />17 <br />SPACE <br />- <br />- <br />- <br />— <br />- <br />- <br />- <br />SPACE <br />18 <br />19 <br />SPACE <br />- <br />- <br />- <br />�~ <br />- <br />-- <br />_ <br />SPACE <br />20 <br />ELECTRICAL SYMBOLS <br />SYMBOL DESCRIPTION AFF <br />REMARKS <br />TO TOP <br />xx nLIGHT DIMMING CONTROL DIMMING CONTROL. LOWER CASE <br />® 48 <br />SWITCH CAT5E CONNECTED LETTERS DESIGNATE ZONING <br />PC <br />nLIGHT nPP20PL <br />ABOVE <br />CONTROLLED BY nLIGHT ENABLED <br />PLUG LOAD CONTROL RELAY <br />CEILING <br />FIXTURE OCCUPANCY SENSORS <br />PP <br />nLIGHT nPP16 THERMOSTAT <br />ABOVE <br />CONTROLLED BY nLIGHT ENABLED <br />CONTROL RELAY <br />CEILING <br />FIXTURE OCCUPANCY SENSORS <br />TR <br />DUPLEX RECEPTACLE <br />20„ <br />180 VA EACH <br />HALF CONTROLLED HALF HOT <br />TAMPER RESISTANT <br />TR <br />QUADPLEX RECEPTACLE <br />20„ <br />180 VA EACH <br />HALF CONTROLLED HALF HOT <br />TAMPER RESISTANT <br />SINGLE RECESSED CLOCK <br />84" <br />180 VA EACH <br />HANGER RECEPTACLE <br />WEATHER RESISTANT GFCI <br />20" <br />180 VA EACH <br />nGFCI <br />RECEPTACLE <br />PHONE /DATA BOX <br />20„ <br />4" SQ BOX SINGLE GANG MR WITH <br />3/4" CONDUIT UP AND DOWN <br />FIRE ALARM PULL STATION <br />48" <br />4" SQUARE BOX w/ SINGLE GANG MUD <br />RING — 3/4" RACEWAY STUB UP ONLY <br />FIRE ALARM INTERIOR <br />84 <br />HORN / STROBE <br />PAINT BOX, MUDRING AND RACEWAY <br />"RED" 1N COLOR <br />FIRE ALARM EXTERIOR <br />HORN / STROBE <br />84 <br />OT <br />THERMOSTAT <br />48" <br />4" SQ BOX SINGLE GANG MR WITH <br />1/2" CONDUIT STUB UP <br />LED WALL PACK <br />84" <br />75 VA EACH <br />nLIGHT ENABLED LED TROFFER <br />® <br />w/ INTEGRAL SENSORS <br />CEILING <br />53 VA EACH <br />ELECTRICAL PANEL <br />72" <br />'11 N I t1 E L11 -1 <br />A Rv <br />
The URL can be used to link to this page
Your browser does not support the video tag.