Laserfiche WebLink
I <br />nPP16 <br />PACK TO <br />THERM <br />OCCUPIED f <br />14 <br />.ELECTRICAL <br />RI ` <br />• A' <br />H.V.A. <br />t <br />I OPERATION <br />O' VOLTAGE <br />[ <br />I <br />COMPRESSOR <br />OUTDOOR <br />INDOOR BLOWER <br />MINIMUM CIRCUIT AMPS <br />«AMPS <br />MAXIMUM OVERCURRENT PROTECTION <br />80 <br />AMPS <br />OVERCURRENT PROTECTION— <br />OR , CIRCUIT BREAKER <br />Y <br />NOTE: ALL DEVICES &FACE <br />PLATES TO BE IVORY <br />GENERAL NOTES: <br />1. WHEN STRANDED WIRE IS USED, ALL TERMINATIONS ARE MADE BY <br />A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID CONDUCTORS <br />OR OTHER APPROVED MEANS OF TERMINATION. <br />2. ALL CONDUCTORS ARE COPPER; TYPE THHN / THWN <br />3. RATING OF STANDARD PANEL IS 22,000 A.I.C. <br />4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE. <br />5. HVAC DISCONNECTS SHALL BE LABELED WITH AN IDENTIFICATION <br />PLATE SHOWING CIRCUIT NUMBER AND EQUIPMENT SERVED. <br />WAC 296-46B-1 10 022 <br />6. EXTERIOR WEATHER PROOF GFCI SHALL HAVE A "HEAVY DUTY' <br />WEATHER PROOF "IN USE' COVER. 2014 NEC 406.9(B) (1) <br />7. CONTROLLED RECEPTACLES SHALL BE LABELED PER 2014 NEC <br />406.3(E) WITH THE TEXT "CONTROLLED" AND THIS SYMBOL � <br />8. THIS PLAN IS NOT AN "AS -BUILT' CIRCUITS MAY BE RUN DIFFERENT <br />THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. <br />, <br />1. ALL LIGHTING SHALL CONFORM TO SECTION C405 <br />2. BASE CLASSROOM LIGHTING POWER DENSITY (C405.4.2.1) <br />833 SQ. FT. x l WATT PER SQUARE FOOT = 833 WATTS ALLOWED <br />ADDITIONAL REDUCTION IN LIGHTING POWER DENSITY (C406.3.1) <br />833 WATTS ALLOWED (BASE) x .75 = 625 WATTS ALLOWED <br />TOTAL WATTS ALLOWED = 625 <br />TOTAL WATTS INSTALLED = 477 WATTS <br />% OF ALLOWED INSTALLED = 76% <br />3. 100% OF LIGHTING FIXTURES HAVE EMBEDDED OCCUPANCY AND <br />DAYLIGHT SENSORS FOR INCREASED ENERGY SAVINGS, AND ARE <br />INDIVIDUALLY ADDRESSABLE. (C406.4) <br />4. 100% OF LIGHTING IS SET FOR CONTINUOUS DIMMING AND IS <br />ADJUSTABLE BY OCCUPANTS, FOR OCCUPANT COMFORT, VIA <br />WALL PODS. (C406.4) <br />5. 50% OF RECEPTACLES ARE CONTROLLED BY LOCAL OCCUPANCY <br />SENSORS (C405.10) <br />6. THERMOSTAT OCCUPIED PERIOD WILL BE DETERMINED BY THE <br />nLIGHT OCCUPANCY SENSORS INTEGRAL TO THE LIGHTING <br />FIXTURES. <br />ELECTRICAL PLAN REVIEW <br />I W <br />LOAD CALCULATIONS <br />VOLTAGE: <br />120/240 <br />PHASE: <br />1 � <br />CONNECTED LOAD <br />CALL. LOAD <br />LIGHTING <br />EXTERIOR <br />75 VA <br />x <br />125 <br />% = <br />94 VA <br />INTERIOR <br />477 VA <br />x <br />125 <br />% = <br />596 VA <br />RECEPTACLES <br />THRU 10,000 <br />3240 VA <br />x <br />100 <br />% = <br />3240 VA <br />OVER 10,000 <br />0 VA <br />x <br />50 <br />% = <br />0 VA <br />MOTORS, COMPR. <br />TOTAL <br />4104 VA <br />x <br />100 <br />% = <br />4104 VA <br />LARGEST <br />(2632) VA <br />x <br />25 <br />% = <br />708 VA <br />HEATING <br />10000 VA <br />x <br />100 <br />% = <br />10000 VA <br />TOTAL KVA <br />17.90 <br />TOTAL <br />KVA <br />18.74 <br />CONNECTED <br />CALCULATED <br />LOAD AMPS <br />74.57 <br />LOAD <br />AMPS <br />78.09 <br />COPYRIGHTi iINDUSTRIES, 911 1 <br />11 <br />THIS MATERIAL PROPERTY <br />i -' R `�� � Classroom t <br />OF BLAZER INDUSTRIES, INC, AND SHALL Ell <br />INS 5W. BE REPRODUCED, DISCLOSED j 'Stock <br />. _ <br />TO OTHERS EXCEPT AS AUTHORIZED BY THE <br />ONE-UNE-D�AGRA <br />100 AMP FEEDER PANEL <br />MAIN BREAKER <br />120/240 1� <br />100 AMP <br />1/2" PVC 1-1/2" PVC STUB THRU <br />STUB FOR BY BLAZER <br />FUTURE (2) #2 Cu THHN <br />GROUNDING (1) #4 Cu THHN <br />AND (1) #6 Cu <br />BONDING (WIRE ON SITE BY OTHERS) <br />SCHEDULEPANEL <br />NOTE: ALL CONDUCTORS COPPER. <br />100 AMID 10 22,000 AIC <br />CKT <br />DESCRIPTION <br />TRIP <br />WIRE <br />VOLT <br />100 <br />VOLT <br />WIRE <br />TRIP <br />DESCRIPTION <br />CKT <br />A <br />NO. <br />AMPS <br />SIZE <br />AMPS <br />B <br />�� <br />— <br />AMPS <br />SIZE <br />AMPS <br />NO. <br />1 <br />LIGHTS <br />20 <br />12 <br />552 <br />—�\ <br />7052 <br />4 <br />s0 <br />HVAC <br />2 <br />3 <br />RECEPTACLES <br />20 <br />12 <br />1260 <br />7052 <br />/ <br />/ <br />f <br />4 <br />5 <br />RECEPTACLES <br />20 <br />12 <br />1060 <br />- <br />- <br />- <br />SPACE <br />6 <br />7 <br />RECEPTACLES <br />20 <br />12 <br />900 <br />- <br />- <br />- <br />SPACE <br />g <br />9 <br />SPACE <br />- <br />- <br />- <br />- <br />- <br />- <br />SPACE <br />10 <br />11 <br />SPACE <br />- <br />- <br />- <br />- <br />-- <br />SPACE <br />12 <br />13 <br />SPACE <br />- <br />- <br />- <br />- <br />_. <br />- <br />SPACE <br />14 <br />15 <br />SPACE <br />- <br />- <br />- <br />- <br />- <br />- <br />SPACE <br />16 <br />17 <br />SPACE <br />- <br />- <br />- <br />— <br />- <br />- <br />- <br />SPACE <br />18 <br />19 <br />SPACE <br />- <br />- <br />- <br />�~ <br />- <br />-- <br />_ <br />SPACE <br />20 <br />ELECTRICAL SYMBOLS <br />SYMBOL DESCRIPTION AFF <br />REMARKS <br />TO TOP <br />xx nLIGHT DIMMING CONTROL DIMMING CONTROL. LOWER CASE <br />® 48 <br />SWITCH CAT5E CONNECTED LETTERS DESIGNATE ZONING <br />PC <br />nLIGHT nPP20PL <br />ABOVE <br />CONTROLLED BY nLIGHT ENABLED <br />PLUG LOAD CONTROL RELAY <br />CEILING <br />FIXTURE OCCUPANCY SENSORS <br />PP <br />nLIGHT nPP16 THERMOSTAT <br />ABOVE <br />CONTROLLED BY nLIGHT ENABLED <br />CONTROL RELAY <br />CEILING <br />FIXTURE OCCUPANCY SENSORS <br />TR <br />DUPLEX RECEPTACLE <br />20„ <br />180 VA EACH <br />HALF CONTROLLED HALF HOT <br />TAMPER RESISTANT <br />TR <br />QUADPLEX RECEPTACLE <br />20„ <br />180 VA EACH <br />HALF CONTROLLED HALF HOT <br />TAMPER RESISTANT <br />SINGLE RECESSED CLOCK <br />84" <br />180 VA EACH <br />HANGER RECEPTACLE <br />WEATHER RESISTANT GFCI <br />20" <br />180 VA EACH <br />nGFCI <br />RECEPTACLE <br />PHONE /DATA BOX <br />20„ <br />4" SQ BOX SINGLE GANG MR WITH <br />3/4" CONDUIT UP AND DOWN <br />FIRE ALARM PULL STATION <br />48" <br />4" SQUARE BOX w/ SINGLE GANG MUD <br />RING — 3/4" RACEWAY STUB UP ONLY <br />FIRE ALARM INTERIOR <br />84 <br />HORN / STROBE <br />PAINT BOX, MUDRING AND RACEWAY <br />"RED" 1N COLOR <br />FIRE ALARM EXTERIOR <br />HORN / STROBE <br />84 <br />OT <br />THERMOSTAT <br />48" <br />4" SQ BOX SINGLE GANG MR WITH <br />1/2" CONDUIT STUB UP <br />LED WALL PACK <br />84" <br />75 VA EACH <br />nLIGHT ENABLED LED TROFFER <br />® <br />w/ INTEGRAL SENSORS <br />CEILING <br />53 VA EACH <br />ELECTRICAL PANEL <br />72" <br />'11 N I t1 E L11 -1 <br />A Rv <br />