My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
616 PECKS DR 2021 Plans 2022-11-29
>
Address Records
>
PECKS DR
>
616
>
Plans
>
616 PECKS DR 2021 Plans 2022-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2022 1:06:28 PM
Creation date
10/19/2021 10:32:58 AM
Metadata
Fields
Template:
Address Document
Street Name
PECKS DR
Street Number
616
Permit
B2105-023
Year
2021
Notes
New 887sf portable P1, landing, and ramp to be installed
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 M <br />1/2"x 5" LONG W/ 3" EMBEDMENT <br />INTO PRECAST PAD TYP 2 PLACES <br />I— --? 2) 3 BARS EACH DIRECTION <br />8„ T OM BARS TO BE 1" CLEAR <br />F BOTTOM <br />16" BARS TO BE ASTM A-65, GRADE 50 <br />PRECAST PAD DETAIL <br />Scale: 1/2 = V-0" <br />Scale: 1/2 = V-0" <br />CMU BLOCK <br />I —° 7/16" SKIRTING <br />L l L N° <br />t�') Scale: 1/2 = V-0" <br />IFTTILifflueWT <br />N11 SAIM <br />8x16 CMU BLOCKS <br />PRECAST •SQUARE <br />REINFORCED i 11 •&D <br />SOIL ANCHOR <br />PER <br />SHEET F-1. <br />CROSS—DRSHOVEL <br />PLATE SHOWN. <br />PER ANCHOR <br />SOIL O. R NOIJ <br />SHEET F-1 <br />4ANCHOR DETAIL <br />F 1 _ gCadkx/2 = V-0" <br />F1 __1 ) 5 voi7-u� 1'-0„ <br />1/2"W x 4 1/2"' LONG EOLTS <br />N/ 1 1/2" 0 WASHERS ® 32" <br />D,C. AND 6"FROM EACH END <br />4x6 PT HF2 POST W/A35 OR <br />SDS25300 TO BEAM & PADS <br />�x12x24" LONG PT HF 2 WOOD <br />�t Scale: 1/2 = V-0" <br />FLOOR JOIST, TOE —NAILED TO <br />BEAM <br />4x 8 H.F. #2 MIDSPAN BEAM <br />PT 2x4x12" LONG POST BEARING <br />BLOCK, NAILED TO BEAM & PT <br />POST W/(2) 16d. <br />PT 4x4 HF2 POST W/A35 OR <br />SDS25300 T&B <br />2x12x24" LONG PT HF2 WOOD PAD <br />—a = W/ 2X4 OVER CENTERED ON PT 4x4 <br />POST AND NAILED TO PT 2x12 OR <br />16x16x4 CONC. PAD W/(2) 10d GALV <br />MID -SPAN BEAMSPLICE <br />Scale: 1/2" = V-0" <br />°2„ x 4 1/2" LONG DOLTS <br />1 1/2" 0 WASHERS <br />O.C. AND 6"FROM EACH <br />D <br />PT WOOD SHIM AS NECESSARY <br />8x 16 CMU BLOCKS <br />RECAST 16" SQ. x4" <br />EINF. CONC. PAD, <br />LT: 2x12x24" LONG <br />T HF2 WOOD PAD <br />r6A L SUPPORT, OPTIONAL <br />Scale: 1/2 = V-0" <br />BLOCKING <br />48 H"F, 2 MIDSPAN <br />SUPPORT EAM <br />JACKSTAND <br />PRECAST 16" SQ. x4" <br />REINF. CONC. PAD, <br />N41 <br />Cxp <br />rs <br />t�) Scale: 1/2 = V-0" <br />J" NOMINAL SHEATHING W/8d @ <br />4"/12" W/ WATERPROOFING TO 6" <br />ABOVE GRADE.EXPOSED <br />WATERPROOFING1'' USE UV STABLE <br />WATERPROOFING PRODUCT. <br />PT 2X4 D AT EACHJOIST <br />' t 0 -i OEACH D <br />•; RUNNER NAILED TO PLATE <br />6D @ w <br />PERPLAN <br />(NOTES: <br />1. USE THIS DETAIL WHERE REQUIRED TO MEET GRADE. <br />2. MAX. SUBGRADE TO GRADE HEIGHT IS 36". <br />BACKFILLED WALL DETAIL <br />., 11 mir'' <br />o go I <br />F1 ) Scale: 1/4" - V-0" <br />STRUCTURALCLASSROOM <br />1. GENERAL: <br />1.1. MODULAR BUILDING MAY VARY BY MANUFACTURER. VERIFY DIMENSIONS AND OTHER CHARACTERISTICS PRIOR <br />TO BEGIN OF FOUNDATION INSTALLATION. MINOR VARIATIONS OF DIMENSION DO NOT CHANGE THE <br />FOUNDATION DESIGN AND INSTALLATION REQUIREMENTS. <br />1.2. MODULAR BUILDING DESIGN CRITERIA ARE ESTABLISHED FOR GENERAL WORST CASE IN LARGE REGIONS. THESE <br />FOUNDATION PLANS ARE DESIGNED FOR SMALLER MORE SPECIFIC DESIGN AREAS AND MAY NOT MATCH THE <br />BUILDING DESIGN CRITERIA. MATCH THE FOUNDATION TO THE SPECIFIC SITE. BUILDING DESIGN MAY MATCH OR <br />EXCEED FOUNDATION DESIGN CRITERIA. <br />2. DESIGN INFORMATION & LOADING: <br />2.1. BUILDING CODE IBC, 2015/2018, OSSC2019 <br />2.2. RISK CATEGORY II <br />2.3. ROOF LIVE LOAD 25 PSF, SNOW <br />2.4. FLOOR LIVE LOAD 40 PSF OR 1,000# CONC. <br />2.5. WIND CRITERION 110 MPH, EXP C, I<zt=1.0 <br />2.6. SEISMIC CRITERION Sds = 1.20, Is=1.0, CATEGORY D <br />2.7. SOIL BEARING 1,500 PSF, SITE CLASS D <br />3. CONCRETE: <br />3.1. DESIGN COMP.STRENGTH 2,500 PSI <br />3.2. REINFORCING BAR YIELD 60 KSI <br />4. MASONRY: <br />4.1. 8x16x8 UNITS ASTM C-90, GRADE N <br />4.2. SET UNITS W/CORES VERTICAL & NO MORE THAN 3 HIGH, PER PLAN <br />5. WOOD: <br />5.1. ALL WOOD MEMBERS OF THE FOUNDATION SYSTEM SHALL BE SPF-STD OR BETTER, UNLESS NOTED OTHERWISE. <br />5.2. ALL WOOD IN CONTACT OR WITHIN 8-INCHES WITH SOIL SHALL BE PRESERVATIVE TREATED. <br />5.3. CONNECTORS USED IN PRESERVATIVE TREATED WOOD MEMBERS SHALL BE STAINLESS STEEL OR HOT -DIPPED <br />GALVANIZED TO THE GALVANIZING WEIGHT AS SPECIFIED IN IN ASTM A 153. <br />5.4. SKIRTING IS NOT INTENDED TO BE A'SHEAR WALL', RATHER A SKIN FOR ENCLOSURE OF THE CRAWLSPACE. <br />5.5. PROVIDE 18" MIN. CLEARANCE FROM SOIL TO UNDERSIDE OF ANY UNTREATED WOOD MEMBER. <br />6. SPECIALTY ITEMS: 'MINUTEMAN'OR EQUAL, www.minutemanproduxcts.com <br />6.1. METAL PIERS TO BE CAPABLE OF SUPPORTING 6,000# <br />6.2. SOIL ANCHORS SHALL BE "MINUTEMAN" IN CONFORMANCE WITH THE TYPE SPECIFIED BY THE MANUFACTURER <br />FOR THE SITE SPECIFIC SOILS AND SHALL CONFORM TO THE FOLLOWING: <br />6.2.1. DESIGN WORKING STRESS LOAD OF 3,150# W/ AN ULTIMATE STRENGTH LOAD OF 4,725# <br />6.2.2. INSTALL GROUND PORTION OF THE ANCHOR PRIOR TO SETTING THE BUILDING. <br />6.2.3. CONNECT ANCHOR TIES TO BUILDING ONLY AFTER BUILDING IS FULLY BLOCKED AND LEVELED. <br />6.2.4. ANCHORS TO BE ONE OF THE FOLLOWING: <br />6.2.4.1. SOIL CLASS 1 (ROCK): 36-XDH <br />6.2.4.2. SOIL CLASS 2 (ASPHALT W/GRAVEL BASE OR GRANULAR STRUCTURAL FILL): (1) GW2NU OR (2) 36-XDH. <br />6.2.4.3. SOIL CLASS 3 (LOOSE SANDS & GRAVELS, STIFF SILTS & CLAYS): 92-4430-DH 1 OR GW2NU <br />AUGER -ANCHOR SET VERTICAL W/6" STABILIZER HEAD OR (2) 48-XDH DRIVEN ANCHORS, EA W/SD2A <br />STABILIZER PLATE SOIL CLASS 4 (LOOSE SANDS, FIRM CLAYS AND SILTS, ALLUVIAL FILLS): 93-4636-DH 4 <br />AUGER ANCHOR SET VERTICAL \A//6" STABILIZER HEAD. <br />6.3. INSTALL ALL SPECIALTY ITEMS PER THE MANUFACTURER'S RECOMMENDATIONS. <br />7. VENTING: <br />7.1. INSTALL A CLASS I VAPOR RETARDER OVER THE CRAWLSPACE AREA TO EXTERIOR OF BUILDING. <br />7.2. PROVIDE CRAWL SPACE VENTILATION PER IBC CODE AND LOCAL REQUIREMENTS AT 1 NET SF OF VENTILATION <br />PER 1500 SF OF FLOOR AREA. <br />8. ACCESS: <br />8.1, PROVIDE ACCESS TO THE UNDER FLOOR AREA PER THE IBC CODE. <br />8.2. PROVIDE 18" MIN. CLEARANCE UNDER FROM SOIL TO UNDERSIDE OF ALL BUILDING STRUCTURE. <br />9. SITE CONDITIONS: <br />9.1. FOUNDATION SUBGRADE TO BE 4-INCHES OF ROAD -MIX GRAVEL, STRUCTURAL FILL OVER UNDISTURBED NATIVE <br />SOILS OR STRUCTURAL FILL,. <br />9.2. STRUCTURAL FILL TO BE COMPACTED TO 95% OF THE STANDARD PROCTOR DENSITY PER ASTM D-698. <br />9.3. SLOPE FINISHED GRADE AWAY FROM THE BUILDING FOUNDATION AT MIN. GRADE OF 2%. <br />10. SPECIAL STRUCTURAL INSPECTION (IBC CHAPTER 17): <br />10.1. —NO SP-ECFAL S-TI-IJ&TUR-AL-IN-SREC-F[ON-�S=REaU,[R=E-D <br />III" E, E p 7 <br />I-efl, ,IN�E FOR E R I 01iI <br />REMENiS: ®ECEAI6ER 3% 2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.