(E) FLOOR CONSTRUCTION, NO <br />PENETRATION, OR PENETRATION <br />PER DETAIL 3/* OR 4/* <br />(N) HUMIDISTAT TYPE, CONSTANT RUNNING <br />2 SPEED EXHAUST FAN; S.M.D. <br />(N) 4° VENT DUCT IN JOIST <br />BAY, EXHAUST TO EXTERIOR, S.M. D. <br />(N) BLOCKING AS NEEDED TO <br />INSTALL CLG RADIATION <br />DAMPER AND FAN <br />(N) $" TYPE 'X' FIRE RATED <br />GYPPUM BOARD LINED CAVITY <br />-HOUR RATED DRYWALL (N) <br />SC- <br />40 <br />!,Wee <br />4 R�' <br />MAINTAIN _ <br />HORIZONTALFLOOR/ <br />ASSEMBLY BETWEEN UNITO E <br />(N) 4" 0 DUCT, <br />SHOWN APPROX <br />CORE TIGHT THROUGH <br />(E) 2X10 C 16" O.C. CENTERLINE OF BLOCKING TO <br />(DO NOT DISTURB) EXTERIOR FACE OF FINISH <br />r <br />CL <br />i— <br />(E) OR (N) JOIST <br />BLOCK <br />(N) 1-HR RATED FLOOR/CEILING <br />ASSEMBLY W1 (N)%" TYPE 'X' GYPSUM <br />BOARD, BY CERTAINTEED OR APPROVED <br />EQUAL. FIRE TAPE Et SEAL FULLY. <br />UNIT I I I I UNIT <br />w <br />5 (N) EX"HAUST VENTING THROUGH JOIST BLOCKING <br />SCALE: 3" = 1' d" <br />LINE JOIST BAY WITH TYPE'X' <br />FIRE RATED GYPSUM BOARD, FIRE <br />TAPE AND SEAL ALL JOINTS <br />(N) VENT W/ INTEGRAL <br />SOLID DUCT <br />BACK DRAFT DAMPER (N) 4" DUCT <br />SET VENT IN SEALANT <br />ALL AROUND. <br />5 <br />LINE JOIST BAY WITH- TYPE 'X' <br />a <br />FIRE RATED GYPSUM BOARD, FIR <br />FINGER TOOL EXCESS <br />TAPE AND SEAL ALL JOINTS <br />(PRESSED OUT) <br />� <br />SEALANT ALL SIDES <br />W <br />A <br />SECTION A -A <br />METALLIC DUCT THROUGH FLOOR/CEILING <br />1. FLOOR - CEILING ASSEMBLY — THE 1 HR FIRE -RATED WOOD JOIST FLOOR -CEILING ASSEMBLY SHALL BE <br />CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 DESIGNS IN THE UL <br />FIRE RESISTANCE DIRECTORY, AS SUMMARIZED BELOW: <br />A. FLOORING SYSTEM — LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR <br />FLOOR TOPPING MIXTURE` AS SPECIFIED IN THE INDIVIDUAL FLOOR -CEILING DESIGN. MAX DIAM OF <br />FLOOR OPENING IS 7 IN. <br />B. WOOD JOISTS — NOM 10 IN. DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL <br />JOISTS, TRUSSES OR STRUCTURAL WOOD MEMBERS WITH BRIDGING AS REQUIRED AND WITH ENDS <br />FIRESTOPPED. <br />C. GYPSUM BOARD* — NOM 5/8 IN. (16 MM) THICK AS SPECIFIED IN THE INDIVIDUAL FLOOR -CEILING <br />DESIGN. WALLBOARD SECURED TO JOISTS AS SPECIFIED IN THE INDIVIDUAL FLOOR -CEILING DESIGN, <br />MAX DIAM OF CEILING OPENING IS 7 IN. <br />2. THROUGH PENETRANTS — NOM 6 IN. DIAM (OR SMALLER) MIN 30 GA. DUCT TO BE INSTALLED CONCENTRICALLY <br />OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. DUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR <br />ASSEMBLY. <br />3. FILL, VOID OR CAVITY MATERIAL - CAULK — MIN 3/4 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, <br />FLUSH WITH TOP SURFACE OF SUBFLOOR AND MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN <br />ANNULUS, FLUSH WITH BOTTOM SURFACE OF CEILING. AT POINT CONTACT LOCATIONS, A MIN 1 /4 IN. DIAM BEAD <br />OF FILL MATERIAL SHALL BE APPLIED TO THE SUBFLOOR/DUCT AND CEILING/DUCT INTERFACES. RECTORSEAL — <br />METACAULK 150+ <br />t <br />3 - <br />PENETRATION <br />A <br />NO SCALE UL SYSTEM NO. F-C-7047 (1 <br />s <br />v� <br />N <br />Q <br />SECTION A -A <br />A.B.S PIPE THROUGH FLOOR/CEILING <br />1. FLOOR — CEILING ASSEMBLY — THE 1 HR FIRE -RATED SOLID JOIST FLOOR -CEILING ASSEMBLY SHALL BE CONSTRUCTS <br />OF THE MATERIALS AND IN THE MANNER SPECIFIED IN INDIVIDUAL L500 SERIES FLOOR -CEILING DESIGNS IN THE UL <br />FIRE RESISTANCE DIRECTORY. <br />A. FLOORING SYSTEM — PLYWOOD SUBFLOOR WITH FINISH FLOOR OF PLYWOOD. MAX DIAM OF FLOOR <br />OPENING IS 4 IN. <br />B. WOOD JOISTS — NOM 2 BY 10 IN. LUMBER JOISTS SPACED 16 IN. OC WITH NOM 1 BY 3 IN. LUMBER BRIDGING <br />AND WITH ENDS FIRESTOPPED. <br />C. FURRING CHANNELS — (NOT SHOWN) — RESILIENT GALV STEEL FURRING INSTALLED PERPENDICULAR TO <br />WOOD JOISTS (ITEM 1 B) BETWEEN GYPSUM BOARD (ITEM 1 D) AND WOOD JOISTS AS REQUIRED 1N THE <br />INDIVIDUAL FLOOR -CEILING DESIGN. <br />D. GYPSUM BOARD* — NOM 4 FT WIDE BY 5/8 IN. THICK. GYPSUM BOARD SECURED TO WOOD JOISTS OR <br />FURRING CHANNELS. MAX DIAM OF CEILING OPENING IS 4 IN. <br />2. THROUGH -PENETRANTS — ONE NONMETALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED WITHIN THE FIRESTOP <br />SYSTEM, DIAM OF OPENINGS HOLE -SAWED THROUGH FLOORING SYSTEM AND THROUGH GYPSUM BOARD CEILING <br />TO BE 1 /4 TO 1-5/8 IN. (6 TO 41 MM) LARGER THAN THE OUTSIDE DIAM OF THROUGH -PENETRANT. PIPE, <br />CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR -CEILING ASSEMBLY. THE <br />FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES, CONDUITS OR TUBING MAY BE USED: <br />D. ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE — NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 <br />CELLULAR OR SOLID CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, <br />WASTE OR VENT) PIPING SYSTEM. THE ANNULAR SPACE SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1 <br />IN. EXCEPT THAT WHEN NOM PIPE DIAM EXCEEDS 1-1 /2 IN., THE MAX ANNULAR SPACE IS 5/8 IN. <br />3. FILL, VOID OR CAVITY MATERIAL — SEALANT — MIN 3/4 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN <br />ANNULUS ON TOP SURFACE OF FLOOR. MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS ON <br />BOTTOM SURFACE OF CEILING ASSEMBLY. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1 /8 IN. <br />CROWN IS FORMED AROUND THE THROUGH PENETRANT ON BOTTOM SURFACE OF CEILING WALL ASSEMBLY. <br />SPECIFIED TECHNOLOGIES INC — SPECSEAL SERIES SSS SEALANT, R SPECSEAL LCI SEALANT, OR TYPE WF300 <br />FIRESTOP CAULK <br />PENETRATION S <br />i 5 <br />t <br />�f i � d <br />Mf <br />x`II� <br />F L f <br />6 <br />NO SCALE UL SYSTEM ,O. ` - - __ : <br />UNIT EXTERIOR )� '"� INTERIORIl F-1 <br />A A <br />L <br />6 ON') EXHAUST VENTING THROUGH <br />LOWEREXHAUST <br />THROUGH LEVEL UNIT <br />BUILDING EXTERIOR. <br />LINE EACH JOIST BAY CAVITY <br />TYPEX'GYSPSUM BOARD, <br />rD <br />A, TO BUILDING CIO <br />DUCTSPROVIDE (N) FIRE -DAMPER IN LINE <br />WITH (N) EXHAUST AT <br />LAUNDRY <br />f BATHROOMTOTAL, <br />[II <br />SECTION A -A <br />METALLIC DUCT THROUGH WALL <br />1. WALL ASSEMBLY — THE 1 HR FIRE -RATED GYPSUM BOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE <br />MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300, U400, V400 OR W400 SERIES WALL AND <br />PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION <br />FEATURES: <br />1A. STUDS — WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO <br />CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS <br />BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE AND SPACED MAX 24 IN. OC. <br />1 B. GYPSUM BOARD* — 5/8 IN.THICK, 4 FT WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM BOARD TYPE, <br />THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE <br />INDIVIDUAL DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING AS SHOWN IN TABLE BELOW <br />2. THROUGH PENETRANT — ONE NOM 4 IN. DIAM (OR SMALLER) NO. 30 MSG (OR HEAVIER), OR ONE NOM 6 IN. DIAM (OR <br />SMALLER) NO. 28 MSG (OR HEAVIER), OR NOM 20 IN. DIAM (OR SMALLER) NO. 22 MSG (OR HEAVIER) STEEL VENT <br />DUCT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM (SEE TABLE <br />BELOW). THE ANNULAR SPACE BETWEEN DUCT AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. (POINT CONTACT) <br />TO MAX VALUE SHOWN IN TABLE BELOW. DUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. <br />3. FILL, VOID OR CAVITY MATERIALS* — SEALANT — MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN <br />ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. AT THE POINT CONTACT LOCATION BETWEEN THROUGH <br />PENETRANT AND GYPSUM BOARD, A MIN 3/8 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE GYPSUM <br />BOARD/THROUGH PENETRANT INTERFACE ON BOTH SURFACES OF WALL.RECTORSEAL — FLAMESAFEO FS 1900, <br />FLAMESAFEO FS900+, METACAULK MC 150+, METACAULK 1000, METACAULK 3501, BIOSTOP BF 150+, BIOSTOP 3501 OR <br />BIOSTOP 500+ <br />: <br />i <br />THROUGH <br />IIr 3 .F <br />i <br />4-PENETRATION <br />3 <br />i" <br />r S <br />9 <br />i 3 '� <br />FIRESTOP <br />f �" <br />v� to <br />i <br />NO SCALE UL SYSTEM NO. 6 { O <br />SECTION A -A <br />A.B.S PIPE THROUGH WALL <br />1. WALL ASSEMBLY — THE 1 HR FIRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED <br />OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION <br />DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: <br />A. STUDS — WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. <br />B. GYPSUM BOARD* — 5/8 IN. THICK, 4 FT WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM <br />WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE <br />AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. <br />MAX DIAM OF OPENING IS 3-1/2 IN. <br />2. NONMETALLIC PIPE — ONE NONMETALLIC PIPE OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM. PIPE <br />OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES OF <br />NONMETALLIC PIPES OR TUBING MAY BE USED: <br />A. POLYBUTYLENE PIPE — NOM 1 IN DIAM (OR SMALLER) SDR 11 (OR HEAVIER) POLYETTYLENE (PB) PIPE FOR <br />USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. A NOM ANNULAR SPACE OF 1 /4 IN. IS REQUIRED <br />WITHIN THE FIRESTOP SYSTEM. <br />B. CROSS LINKED POLYETHYLENE (PEX) TUBING — NOM 1 IN. DIAM (OR SMALLER) SDR 9 PEX TUBING FOR <br />USE IN (PROCESS OR SUPPLY) PIPING SYSTEMS. A NOM ANNULAR SPACE OF 1 /4 IN. IS REQUIRED <br />WITHIN THE FIRESTOP SYSTEM. <br />C. ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE — NOM 1-1/2 IN. DIAM (OR SMALLER) SCHEDULE 40 <br />CELLULAR CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR <br />VENT) PIPING SYSTEMS. THE ANNULAR SPACE SHALL BE MIN 1 /4 IN. TO MAX 1 IN. <br />D. POLYVINYL CHLORIDE (PVC) PIPE — NOM 2 IN. DIAM (OR SMALLER) SCHEDULE 40 CELLULAR OR SOLID <br />CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING <br />SYSTEMS. THE ANNULAR SPACE SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. <br />E. CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE — NOM 2 IN. DIAM (OR SMALLER) SDR 17 CPVC PIPE FOR <br />USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE <br />ANNULAR SPACE SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. <br />3. FILL, VOID OR CAVITY MATERIAL — SEALANT — MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN <br />ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A <br />MIN 1 /4 IN. THICK CROWN IS FORMED AROUND THE PENETRATING ITEM. <br />SPECIFIED TECHNOLOGIES INC — SPECSEAL SERIES SSS SEALANT OR SPECSEAL LCI SEALANT <br />2 WALL t <br />A Y <br />1 <br />FIRESTOP <br />HOUR)NO SCALE UL SYSTEM NO. W-L-2100 (1 <br />PICK,CHARLES <br />REGISTERED9252 <br />ARC ITECT <br />CHARLES PICK <br />VSTATE Oe # <br />EXPIRATION DATE:6/18/2021 <br />(E) WALL TO REMAIN <br />— — — <br />(E) WALL TO BE REMOVED <br />7� <br />(N) INTERIOR PARTITION <br />1 HOUR RATED WALL <br />FOR ISSUE 7/18/19 <br />�A FIELD CLARIFICATIONS 10/16/19 <br />PROJECT NAME: <br />"Al RE <br />APARTMENTS <br />