Laserfiche WebLink
W. <br /> 4 STRUCTURAL NOTES <br /> (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) ENGINEERING <br /> CODE <br /> 250 4TH AVE.S.,SUITE 200 <br /> EDMONDB.WASHINGTON 98020 <br /> ALL MATERIALS,WORKMANSHIP,DESIGN,AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, PHONE(425)778-8500 <br /> SPECIFICATIONS,AND THE INTERNATIONAL BUILDING CODE(IBC),2015 EDITION.SPECIFICATIONS AND STANDARDS FAX(425)778-5536 <br /> WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. <br /> DESIGN LOADS <br /> DEAD LOADS: <br /> ROOF 15 POP <br /> FLOOR 15 PSF ( <br /> LIVE LOADS: ( EL7\ C - <br /> ROOF(SNOW LOAD) 25 PSF ,J <br /> RESIDENTIAL 40 PSF <br /> (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER AC SECTION 1607.10). r o <br /> Fc FOUNDATIONS:SPREAD FOOTINGS wS <br /> M. <br /> SOILS REPORT: NOT AVAILABLE AT TIME OF DESIGN ON; 1T4 ;14,",, <br /> ALLOWABLE SOIL PRESSURE: 1500 PSF(PER IBC 2015 TABLE 1806.2) r . 4 'T <br /> I V / . •- <br /> LUMBER Q 40.0 I! `�ree II, <br /> GRADNG RULES,KIALL GDES ILN-DRIED TOED ARE I MU MC 11 AND OFDES RTHEE FOLLOWING MINIMUM STANDARDSEQUIRED.ALL LUMBER SHALL BE IN ORDANCE WITH WWPA 2 I , �/`Q yl/ <br /> SIZE CLASSIFICATION SPECIES GRADE Fb(PSI) Fc(PSI) <br /> Z/2C <br /> 00 00 <br /> SLEEPERS DOUG-FIR STUD 700 - -_ -- <br /> LIGHT FRAMING(STUDS) HEM-FIR STUD 675 BOO CO we <br /> 2x JOISTS AND PLANKS HEM-FIR k2 850 - <br /> PLATES AND BLOCKING HEM-FIR k2 850 - <br /> 6x AND LARGER BEAMS AND DOUG-FIR k2 875 - t C C <br /> I I 1� <br /> STRINGERS !! <br /> 4n AND SMALLER BEAMS AND HEM-FIR k2 850 - <br /> STRINGERS <br /> ALL POSTS AND TIMBERS DOUG-FIR k1 1200 1000 <br /> FQH- <br /> REFER TO PLAN NOTES,SCHEDULES,AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. .) F- <br /> _ z <br /> UNLESS NOTED OTHERWISE IN THE PLANS,ALL WOOD AND WOOD-BASED MEMBERS EXPOSED TO WEATHER OR IN -_-3 I--o O m <br /> CONTACT WITH CONCRETE,MASONRY,OR WITHIN 8"OF SOIL SHALL BE PRESERVATIVE-TREATED BY x F N <br /> VACUUM-PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD Si. c <br /> �� w'r �? K F <br /> NAILS,BOLTS,AND METAL CONNECTORS FOR WOOD <br /> ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS(NDS)FOR C - <br /> TYP DOUBLE 0 o- <br /> WOOD CONSTRUCTION,LATEST EDITION.NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.9.1 NAILING ri TOP PLATE <br /> SCHEDULE.ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL �~ Ik .AWN O <br /> MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: / N <br /> NAIL SHANKO MIN LENGTH to <br /> I/ <br /> r ! II� O•--I8d COMMON 0.1310 21/2"SHANK + �' ••�- .--I100 COMMON 0.1480 3"SHANK SUII ED A E ERIO(ONLRur <br /> REQUIRED AT EXTERIORSC12d COMMON 0.1480 31/4"SHANK HEADERS GREATER Q16d COMMON 0.1620 3 1/2"SHANK <br /> DESIGN: WMS <br /> 1Od BOX NAILS MAY RE SUBSTITUTED FOR Ed COMMON NAILS WITH NO CHANGE IN NAILSPACING.FRAMING <br /> MEMBERS MAY BE NAILED WITH 16d SINKERS(0.148.0 x31/4"),BUT ONLY 16d COMMON NAILS SHALL BE USED (6)0.131"0x3"NAILSIli <br /> I DRAWN: .LEG <br /> WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET.ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS '" <br /> ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. CHECK: CMJ <br /> ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307.PROVIDE WASHERS UNDER THE HEADS AND NUTS TYPICAL STUDSI' BEAM OR HEADER PER <br /> UpB NO: 20374.1O <br /> OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD.LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THEDATE: 11/25/20 <br /> SHANK AND THREADED PORTIONS PER NOS 11.1.3. ) 4 I NAILINGPERTYPCONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE"STRONG-TIE"BY SIMPSON COMPANY,CATALOGBUILT-UP STUD ,'ITO BE THE LATEST EDITION,OR ENGINEER APPROVED EQUAL.CONNECTORS SHALL BEINSTALLED IN ACCORDANCECOLUMN DETAIL <br /> WITH THE MANUFACTURER'S RECOMMENDATIONS ANDWITH THE NUMBER AND SIZE OF FASTENERSAS SPECIFIED - .1 '0 <br /> BY THE MANUFACTURER.WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS,PLACE ONE-HALF OF THE NAILS, <br /> SCREWS,OR BOLTS IN EACH MEMBER. <br /> AT INSTALL SOLID BLOCKING AT ALL BEARING POINTS.ALL SHIMS SHALL BE SEASONED,DRIED,AND THE SAME GRADE HOLDOWNOW CHS: PERPROVIDE SEWSULL HT CRIPPLEUMNSCH PLAN <br /> CHORDS PER HD SCHED. AND COLUMN SCHEDULE OR <br /> (MINI MUM)AS MEMBERS CONNECTED. OTHERWISE:(1)20 FULL HT STRUCTURAL NOTES <br /> EXISTING BUILDING <br /> CONTRACTOR SHALL VERIFY ALL DIMENSIONS,MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING O SECOND FLOOR FRAMING PLAN © CI TYPICAL HEADER DETAIL <br /> DEPICTED IN THE DRAWINGS,AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE '-0 REDESIGN. SCALE: 1/4"=1 " <br /> IT�-1 SCALE: 1"=1'-0" <br /> CONTRACTOR RESPONSIBLE FOR COMPLETELY SEAUNG ALL AREAS WHERE EXISTING ROOF MATERIAL IS <br /> PENETRATED OR REMOVED.PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. <br /> TYPICAL FLOOR FRAMING PLAN NOTES: <br /> GENERAL <br /> I. COLUMNS SHOWN ON PLANS SHALL BE CONTINUED DOWN <br /> STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL CIVIL ELECTRICAL AND TO THE FOUNDATION UNLESS CARRIED BY A BEAM BELOW. M CV '^ <br /> MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND M C) V/CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING.ANY DISCREPANCIES SHALL BE BROUGHT TO THE W V) <br /> ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. <br /> Z fl F- J_ <br /> CONTRACTOR TO SEE ARCHITECTURAL,CIVIL ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION M i_ 0 Z .CC <br /> OF PIPE,VENT,DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. i- <br /> 0 Z <br /> CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL N W <br /> PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. 03 <br /> O w CD Q <br /> CONTRACTOR-INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL 0 0 Q <br /> ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION.CHANGES SHOWN ON SHOP DRAWINGS Q IX cki <br /> ONLY WILL NOT SATISFY THIS REQUIREMENT. Ce 3 <br /> DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.WHERE CONDITIONS ARE NOT Q >SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO I— <br /> CONSTRUCTION SHALL BE USED,SUBJECT TO REVIEW AND A APPROVAL BBY THE A CHITECT AND THE STRUCTURAL IX Q )S SHOWN,SIMILAR DETAILS OF 0 0 ~" U Cl') <br /> ENGINEER. <br /> U w D Z <br /> Q <br /> Q N > H J f <br /> O Cp w (/) 0- H <br /> SHEET: <br /> • <br /> CITY OF EVERETT <br /> • REVIEWED FOR PERMIT S1.1 <br />