Laserfiche WebLink
• <br /> Mr. Hal Benton <br /> CPM <br /> Plan Check Number: B1903-041, Second Building Review <br /> May 8, 2019 <br /> General: <br /> 1. No additional comment. <br /> 2. No additional comment. <br /> 3. No additional comment. <br /> Fire Protection: <br /> 4. No additional comment. <br /> Egress: <br /> 5. No additional comment. <br /> 6. This comment has not been completely addressed. The original comment stated that the <br /> Occupancy and Exiting Diagram on Sheet A0.02 shall specify additional exit signs. An exit sign <br /> shall be provided at Door 01B. In addition, the sign for Door 01C should be located closer to <br /> the door for clarity. See IBC Section 1013.1 and IEBC Section 801.3. <br /> 7. This comment has not been completely addressed. The original comment stated that means- <br /> of-egress illumination shall be provided per IBC Section 1008. A note has been added to Sheet <br /> A6.01 requiring illumination with back-up power. The locations where the illumination are <br /> required shall be indicated on the ceiling plan. See IEBC Section 801.3. <br /> 8. No additional comment. <br /> 9. This comment has not been completely addressed. The original comment stated that the Site <br /> Plan on Sheet A1.00 appears to show modifications to the existing sidewalk on the north side of <br /> the building. Detail 2/A1.00 has been added in response. See IBC Sections 107.2.1 and <br /> 1102.1. The following comments shall be addressed: <br /> a. No additional comment. <br /> b. The plan specifies 5-foot wings. The wing maximum cross-slopes shall be specified in the <br /> drawings. It appears that maximum slopes of 1:10 are intended. Note that the section <br /> specifies a minimum ramp run of 6 feet. Longer ramps will result in excessive wing slopes. <br /> See IBC Sections 1012.2 and 1012.3, and ICC A117.1-09 Sections 405.2 and 405.3. <br /> c. The ramps shall specify a slip-resistant surface per IBC Section 1012.7.1. The plan specifies <br /> a broom finish. Verify this provides the required slip-resistance; specify the finish to be <br /> performed perpendicular to the ramp slope. <br /> d. Ramps with a rise exceeding 6 inches shall be provided with handrails per IBC Section <br /> 1012.8. The plan specifies a minimum run of 6 feet and slope of 1:12. Longer ramp runs <br /> will result higher rises and require the ramps to include handrails. Review and revise the <br /> detail as needed, and provide handrail details if required. <br /> e. No additional comment. <br /> 0n 3200 Cedar Street 0 425.257.8810 0 everetteps@everettwa.gov <br /> �{ Everett,WA 98201 425.257.8857 fax everettwa.gov/.ermits <br /> Page 2 of 4 <br />