1010 SE EVERETT MALL WAY AEROTEK 2021-11-02
>
Address Records
>
SE EVERETT MALL WAY
>
1010
>
AEROTEK
>
1010 SE EVERETT MALL WAY AEROTEK 2021-11-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2021 1:10:06 PM
Creation date
11/2/2021 1:09:15 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1010
Tenant Name
AEROTEK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
: V • <br /> 9. This comment has not been completely addressed. The original comment stated that the Site Plan on Sheet A1.00 <br /> appears to show modifications to the existing sidewalk on the north side of the building. Detail 2/A1.00 has been <br /> added in response. See IBC Sections 107.2.1 and 1102.1. The following comments shall be addressed: <br /> a. No additional comment. <br /> b. The plan specifies 5-foot wings. The wing maximum cross-slopes shall be specified in the drawings. It <br /> appears that maximum slopes of 1:10 are intended. Note that the section specifies a minimum ramp run <br /> of 6 feet. Longer ramps will result in excessive wing slopes. See IBC Sections 1012.2 and 1012.3,and ICC <br /> A117.1-09 Sections 405.2 and 405.3. <br /> Response: Please see detail 2/A1.00, a note has been added to limit the slope and <br /> cross slope of the wings. <br /> c. The ramps shall specify a slip-resistant surface per IBC Section 1012.7.1. The plan specifies a broom finish. <br /> Verify this provides the required slip-resistance;specify the finish to be performed perpendicular to the <br /> ramp slope. <br /> Response: Please see revised note on detail 2/A1.00 calling out the broom finish <br /> direction and referencing the slip-resistance requirements of IBC section 1012.7.1. <br /> d. Ramps with a rise exceeding 6 inches shall be provided with handrails per IBC Section 1012.8. The plan <br /> specifies a minimum run of 6 feet and slope of 1:12. Longer ramp runs will result higher rises and require <br /> the ramps to include handrails. Review and revise the detail as needed and provide handrail details if <br /> required. <br /> Response: Please see detail 2/A1.00,the 6'-0"ramp run minimum was a typo that <br /> should have read 6'-0" maximum to ensure the overall rise is less than 6",this has been <br /> revised on the detail. <br /> e. No additional comment. <br /> ACCESSIBILITY: <br /> 10. This comment has not been completely addressed. The original comment stated that the project involves Level 2 <br /> Alterations to the building per IEBC Chapter 8,and requires accessibility improvements per IEBC Section 705.2. The <br /> response lists the proposed improvements and the overall estimate cost for this work. See IEBC Section 806.1 and <br /> IBC Section 107.2.1. The following comments shall be addressed: <br /> a. Based on a telephone conversation with Hal Benton on May 8,2019,it is understood that some portions of <br /> the work stated in the response are not included in the project. An example includes replacement of the <br /> existing door handles with accessible handles. The response should be reviewed and revised to accurately <br /> reflect the work occurring in the project. All portions of the work stated in the response shall be clearly <br /> indicated in the construction drawings. All work used to satisfy the requirements of IEBC Section 705.2 <br /> shall be addressing pre-existing conditions. New work that is required to be accessible,or replacement of <br /> existing accessible features with new accessible features,do not qualify. <br /> Response: The following work on this project are upgrades outside of the tenants scope <br /> to meet IEBC section 705.2: overlaying asphalt to raise the portion of the parking lot <br /> around the ADA parking spots, grinding portions of the existing parking lot to accept the <br /> new asphalt overlay, parking lot striping at new ADA parking spots,ADA parking signage, <br /> (3)curb cuts, vertical grab bars, demolition and relocation of restroom doors, relocating <br /> and replacing restroom partitions,ADA pipe insulation at missing locations. Please see <br /> estimates provided by contractor for scope of work. <br /> b. Continuing with the previous comment, the cost estimate should be revised to accurately represent work <br /> occurring in the project. The estimate should be itemized with the portions of work(e.g,bathroom <br /> improvements,accessible parking,etc.). Where needed for clarity,brief narrative shall be provided for <br /> each portion of work to substantiate the itemized costs. <br /> Response: Please see attached itemized estimates for restroom upgrades and parking <br /> upgrades provided by contractor for this permit. <br /> c. The proposed accessible parking and adjacent sidewalk on the north side of the building has been <br /> modified. The extent of the modifications is not clearly shown in the Site Plan on Sheet A1.00. Proposed <br /> work should be delineated with heavier light weights or other standard drawings approaches to <br /> distinguish it from the existing conditions. Provide details for widening the sidewalk. <br /> Response: Linework has been revised for clarity on sheet A1.00. Details for concrete work <br /> have been added to a new sheet on A9.03. <br /> Project#B1903-041 —1010 SE Everett Mall Way <br /> 21 LA <br />