My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10121 EVERGREEN WAY PIZZA HUT 2021-11-02
>
Address Records
>
EVERGREEN WAY
>
10121
>
PIZZA HUT
>
10121 EVERGREEN WAY PIZZA HUT 2021-11-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2021 4:21:42 PM
Creation date
11/2/2021 4:15:59 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10121
Tenant Name
PIZZA HUT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
217
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Bruce S. MacVeigh,P.E. <br /> Civil Engineer/Small Site Geotechnical <br /> 14245 59th Ave. S. <br /> Tukwila, WA 98168 <br /> Cell Ph: 206-571-8794 <br /> September 16, 2019 (Revision) <br /> Subject: Roof-Mounted Unit and Hood Evaluation, Pizza Hut, 10121 <br /> Evergreen Way, Suite 23, Everett, WA 98204 <br /> General. <br /> The existing building will receive new/upgraded roof-mounted restaurant <br /> related units and new interior kitchen hoods. Also, one roof-mounted <br /> HVAC unit will be replaced at same location and a new one installed with <br /> similar installation. It is a one-story tenant unit in an existing building. The <br /> layout of the existing roof has been verified by field measurement. <br /> Weights of units are per manufacturer. Documentation is attached. <br /> Comments/Evaluation Results. <br /> 1. The tenant space is 21' 8"wide and 60 feet long. A major glulam beam <br /> crosses the space 20 feet to the front of the rear wall. Running front to <br /> back are 2" x 4" (Paralam LVL) by 36" high wood roof trusses at 4 foot <br /> spacing. Note the glulam (7.5"wide by 32" deep) is judged adequate <br /> without evaluation. All new units evaluated will be in the front 40 feet of <br /> the space. <br /> 2. Per attached calculations the 36" high roof trusses in the front 40 feet <br /> of the building have no additional moment capacity beyond existing basic <br /> roof loading. The trusses are open lattice 2.0 Paralam LVL (Truss Chord <br /> rated) top and bottom chord and cannot be reinforced to provide additional <br /> moment capacity. The solution is to block beneath the trusses with mid- <br /> span cross-beams with posts in the new building internal front-to-back wall <br /> and side walls. The solid post blocking will reduce the effective span for <br /> the trusses from 40 feet down to about 28 foot maximum span. With the <br /> added post and cross beam blocking under affected trusses (assumed all <br /> trusses), the two new Exhaust Fans#1.and#2 may be installed without <br /> otherwise altering the roof structure. Similarly,the new Makeup Air(MUA) <br /> may be safely installed. <br /> 3. The Makeup Air(MUA) fan for the main hood has a substantial weight <br /> (with air tempering(heating)feature) of about 500#. With all affected roof <br /> trusses having a shortened span with the support blocking, it may be <br /> installed without otherwise altering the roof structure. <br /> 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.