My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11114 EVERGREEN WAY PAPAS BAKERY 2021-11-03
>
Address Records
>
EVERGREEN WAY
>
11114
>
PAPAS BAKERY
>
11114 EVERGREEN WAY PAPAS BAKERY 2021-11-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2021 8:05:42 AM
Creation date
11/3/2021 8:05:19 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
11114
Tenant Name
PAPAS BAKERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> L. Multiple Hood Venting (506.3.5): <br /> 1. Number of hoods vented by a single duct system: Proposed: <br /> A single-duct system may serve more than one hood located in the same story of the building, <br /> provided that the interconnecting ducts do not penetrate any fire resistance rated construction and <br /> are located in adjoining rooms; and the grease duct system does not serve a solid fuel-fired <br /> appliance. <br /> 2. An unlisted hood outlet shall serve not more than a 12-foot section of hood. <br /> M. Provide seismic restraint vertical support and attachment details for the hood; shall be prepared <br /> by someone knowledgeable in structural engineering. (IMC 301.15, IBC 1613, ASCE7-05) Hoods <br /> and equipment over 400 pounds require calculations and details for review. <br /> N. Additional Information—Type I Hood Only: <br /> 1. Grease filters shall be installed at a minimum 45 degrees angle and <br /> equipped with drip tray and gutter beneath lower edge of filters. Proposed: degrees <br /> 2. Distance between lowest edge of grease filters and cooking surface of: <br /> Grill, fryer, exposed flame shall not be not be less than 2 ft. Proposed: ft. <br /> Exposed charcoal, charbroil shall be not less than 3 '/ft. (507.11) Proposed: ft. <br /> 3. Type I hood and duct shall have clearances from construction of: Proposed: in. <br /> GWB on metal stud (minimum 3" clearance required) (506.3.6; 507.2.6) <br /> GWB on wood stud (minimum 18" clearance required) (506.3.6; 507.2.6) <br /> PROTECTED <br /> UNPROTECTED (Combustible Construction) (With 1-hour Fire-Rated <br /> Material and Stud Construction) <br /> Hood Min. Req. 18 in. Proposed /9 of in. Min. Req. 3 in. Proposed 3,Ar in. <br /> Duct Min. Req. 18 in. Proposed in. Min. Req. 3 in. Proposed in. <br /> 4. Hoods less than 12 inches from ceilings or walls shall be flashed,solidly. <br /> 5. All joints and seams shall be made with continuous liquid-tight weld or braze made on the external <br /> surface of the duct system. Vibration insulation connector may be used provided it consists of <br /> noncombustible packing in a metal sleeve joint. (506.3.2, 506.3.2.4) Joints shall be smooth and <br /> accessible for inspection. (506.3.2.5)A light test shall be performed. <br /> 6. Exhaust fans used for discharging grease exhaust shall be positioned so that the discharge will not <br /> impinge on the roof. The fan shall be provided with an adequate drain opening at the lowest point to <br /> permit drainage of grease to a suitable collection device. (506.5.2) <br /> 7. Fire Suppression System Fire Suppression System shall be per Fire Code. Portable extinguisher <br /> shall also be provided per Fire Code. Provide automatic shutoff for make-up air, exhaust system, <br /> and appliances when suppression system is activated. Dependent on suppression agent and <br /> manufacturer's requirements. Separate permit is required. <br /> 8. Performance test certificate of the hood system shall be provided to owner before final approval. <br /> Test shall verify property operation, the rate of exhaust, makeup air, capture and containment <br /> performance of the exhaust at normal operating conditions. (507.6) <br /> 9. A pollution-control unit may be required for side-wall terminations. (506.3.13.2) <br /> References: <br /> 1 —International Mechanical Code(2015) <br /> 2—International Building Code(2015) <br /> 3—International Fire Code(2015) <br /> 4—International Fuel Gas Code(2015) <br />
The URL can be used to link to this page
Your browser does not support the video tag.